OSHA SearchOSHA records by employer

Lombardi Companies: OSHA inspections and violations

Morgantown, West Virginia · Commercial and Institutional Building Construction · NAICS 236220

9inspections
8citation items
$25,498current penalties
Mar 19, 2026last inspection

Since 2018, OSHA inspectors have visited Lombardi Companies in West Virginia 9 times.

The most recent inspection opened on Mar 19, 2026 as a planned inspection, in Morgantown.

In all, OSHA issued 8 citation items: 6 serious and 2 other-than-serious.

The proposed penalties came to $28,487; today they stand at $25,498, 10% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Lombardi Companies averages $8,499 across 3 cited inspections.

Lombardi Companies: OSHA citation items per year, 2018 to 2026
Citation items per year, by inspection date.

West Virginia · latest 90 days of OSHA records

28employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in West Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in West Virginia

Checking a subcontractor, a client or your own company? Watch Lombardi Companies and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348820564 OPENED MAR 19, 2026Closed

Planned · Complete · Safety · 1 employee at the site · Closed May 4, 2026

1000 Mississippi St, Morgantown, WV 26501 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 348803552 OPENED MAR 12, 2026Closed

Planned · Complete · Safety · 3 employees at the site · Closed Jun 9, 2026

661 Green Bag Rd, Morgantown, WV 26501 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$4,502$3,200May 4, 2026Final

Inspection 347682494 OPENED AUG 13, 2024Closed

Planned · Complete · Safety · 3 employees at the site · Closed Oct 2, 2024

2400 Aviation Way, Bridgeport, WV 26330 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 346867013 OPENED JUL 25, 2023Closed

Planned · Complete · Safety · 5 employees at the site · Closed Sep 22, 2023

1976 Parkview Rd, Wheeling, WV 26003 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345410468 OPENED JUL 9, 2021Closed

Planned · No inspection · Safety · Closed Aug 31, 2021

300 Mulberry Ave, Moundsville, WV 26041 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344966239 OPENED OCT 7, 2020Closed

Planned · Partial · Safety · 3 employees at the site · Closed Dec 8, 2020

1550 Goshen Road, Morgantown, WV 26508 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344492087 OPENED DEC 5, 2019Closed

Planned · Partial · Safety · 17 employees at the site · Closed Jul 24, 2020

19 Junior Ave, Wheeling, WV 26003 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Other-than-serious$6,747$5,060May 7, 2020Final
Citation 2, item 1
29 CFR 1926.1153(c)(1) · Silica dust in construction
Other-than-serious$0$0May 7, 2020Final

Inspection 344289509 OPENED SEP 4, 2019Closed

Planned · Partial · Safety · 34 employees at the site · Closed Dec 10, 2019

300 Spruce St, Morgantown, WV 26501 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.150(c)(1)(iv) · Fire protection
Serious$6,630$6,630Oct 15, 2019Final
Citation 1, item 1b
29 CFR 1926.152(d)(2) · Flammable liquids
Serious$0$0Oct 15, 2019Final
Citation 1, item 2a
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$5,304$5,304Oct 15, 2019Final
Citation 1, item 2b
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Oct 15, 2019Final
Citation 1, item 3
29 CFR 1926.452(w)(1) · Rules for each type of scaffold
Serious$5,304$5,304Oct 15, 2019Final
1 older inspection

Inspection 343369013 OPENED AUG 8, 2018Closed

Planned · No inspection · Safety · 2 employees at the site · Closed Aug 22, 2018

Couty Route 219/27, Elkins, WV 26241 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1153 · Silica dust in construction

29 CFR 1926.1153(c)(1)

(c) Specified exposure control methods. (1) For each employee engaged in a task identified on Table 1, the employer shall fully and properly implement the engineering controls, work practices, and respiratory protection specified for the task on Table 1, unless the employer assesses and limits the exposure of the employee to respirable crystalline silica in accordance with paragraph (d) of this section.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(iv)

(iv) One or more fire extinguishers, rated not less than 2A, shall be provided on each floor. In multistory buildings, at least one fire extinguisher shall be located adjacent to stairway.

29 CFR 1926.152 · Flammable liquids

29 CFR 1926.152(d)(2)

(2) At least one portable fire extinguisher having a rating of not less than 20-B units shall be located not less than 25 feet, nor more than 75 feet, from any flammable liquid storage area located outside.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.453 · Aerial lifts

Other commercial and institutional building construction employers in West Virginia

Alert subscribers get notified of each newly cited employer in West Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.