OSHA SearchOSHA records by employer

Mae-Eitel, Inc: OSHA inspections and violations

Orwigsburg, Pennsylvania · All Other Miscellaneous Fabricated Metal Product Manufacturing · NAICS 332999

1inspections
11citation items
$7,000current penalties
Mar 16, 2018last inspection

OSHA has inspected Mae-Eitel, Inc once in Pennsylvania.

The inspection began on Mar 16, 2018 after a complaint, in Orwigsburg.

That inspection ended with 11 citation items: 11 serious.

Penalties were first proposed at $11,637 and now stand at $7,000, 40% lower after settlements or reviews.

Respiratory protection comes up most often in these citations: 4 items under 1910.134.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Mae-Eitel, Inc averages $7,000 (1 cited inspection).

Mae-Eitel, Inc also files yearly injury logs with OSHA, summarized below.

Mae-Eitel, Inc: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Want to know if OSHA cites Mae-Eitel, Inc again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 343023081 OPENED MAR 16, 2018Closed

Complaint · Partial · Health · 42 employees at the site · Closed May 31, 2018

97 Pinedale Industrial Road, Orwigsburg, PA 17961 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$3,879$2,334Apr 27, 2018Final
Citation 1, item 1b
29 CFR 1910.107(b)(10) · Spray painting and finishing
Serious$0$0Apr 27, 2018Final
Citation 1, item 1c
29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing
Serious$0$0Apr 27, 2018Final
Citation 1, item 1d
29 CFR 1910.107(b)(9) · Spray painting and finishing
Serious$0$0Apr 27, 2018Final
Citation 1, item 2a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$3,879$2,333Apr 27, 2018Final
Citation 1, item 2b
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Apr 27, 2018Final
Citation 1, item 2c
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Apr 27, 2018Final
Citation 1, item 2d
29 CFR 1910.134(h)(1)(i) · Respiratory protection
Serious$0$0Apr 27, 2018Final
Citation 1, item 3a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$3,879$2,333Apr 27, 2018Final
Citation 1, item 3b
29 CFR 1910.1200(f)(6)(ii) · Hazard communication
Serious$0$0Apr 27, 2018Final
Citation 1, item 3c
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Apr 27, 2018Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Orwigsburg site logged 0 recordable injuries or illnesses among about 28 workers: 0.0 per 100 full-time workers, against a median of 2.3 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
MAE-Eitel, Inc.
Orwigsburg · 2025
28 000.02.3

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(10)

(10) Illumination. When spraying areas are illuminated through glass panels or other transparent materials, only fixed lighting units shall be used as a source of illumination. Panels shall effectively isolate the spraying area from the area in which the lighting unit is located, and shall be of a noncombustible material of such a nature or so protected that breakage will be unlikely. Panels shall be so arranged that normal accumulations of residue on the exposed surface of the panel will not be raised to a dangerous temperature by radiation or conduction from the source of illumination.

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(b)(5)(iv)

(iv) Space within the spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

Other all other miscellaneous fabricated metal product manufacturing employers in Pennsylvania

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.