OSHA SearchOSHA records by employer

Masonry Builders, Inc.: OSHA inspections and violations

Tampa, Florida · Masonry Contractors · NAICS 238140

29inspections
55citation items
$97,827current penalties
Jun 17, 2025last inspection

Masonry Builders, Inc. has 29 OSHA inspections on record in Florida, the first in 1990.

OSHA's last visit started on Jun 17, 2025 as part of a related case, in Clearwater.

Across those inspections OSHA issued 55 citation items: 36 serious, 9 repeat and 10 other-than-serious.

OSHA proposed $131,489 in penalties. After settlements and reviews the total is $97,827, down 26%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (31 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Masonry Builders, Inc. averages $11,103 over 3 cited inspections in that time.

Masonry Builders, Inc. also files yearly injury logs with OSHA, summarized below.

It reported 4 severe injuries to OSHA since 2015.

Masonry Builders, Inc.: OSHA citation items per year, 1990 to 2025
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

338employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Masonry Builders, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348315250 OPENED JUN 17, 2025Closed

Unprogrammed related · Partial · Safety · 8 employees at the site · Closed Dec 11, 2025

1295 S. Missouri Rd, Clearwater, FL 33756 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 346224827 OPENED SEP 9, 2022Closed

Referral · Partial · Safety · 90 employees at the site · Closed Nov 15, 2022

4820 Tamiami Trail, Sarasota, FL 34231 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343614640 OPENED NOV 19, 2018Closed

Referral · Partial · Safety · 10 employees at the site · Closed May 31, 2019

11525 E State Rd. 70, Lakewood Ranch, FL 34202 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Incident on Nov 12, 2018: Employee falls from scaffold and fractures right ankle, left

At 7:39 a.m. on November 12, 2018, an employee was working to disassemble a scaffold alone. The employee was working to remove the third level ladder portion of the scaffold, shaking it to break it loose. At some point, the employee lost balance and fell approximately eighteen feet and received fractures to his left heel, right ankle and compression injuries to three spinal discs.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(2) · Scaffolds, general requirements
Serious$13,127$13,127Apr 30, 2019Final

Inspection 343492559 OPENED SEP 25, 2018Closed

Referral · Partial · Safety · 48 employees at the site · Closed Mar 12, 2019

11601 Erie Road, Parrish, FL 34219 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Incident on Sep 21, 2018: Employee falls from scaffold, injures head, wrist, and hand

At 9:40 a.m. on September 21, 2018, Employee #1 and coworkers, employed by a masonry construction company, were engaged in masonry work at a multiemployer construction project. Employee #1 was on a scaffold and attempting to hoist a gas container needed by a coworker to operate a saw. Employee #1 fell from the scaffold to the concrete floor, a fall height of 11.5 feet. He was transported to the hospital, admitted, and treated for a head injury and a fractured wrist and hand.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$13,127$9,189Jan 31, 2019Final

Inspection 343413100 OPENED AUG 23, 2018Closed

Unprogrammed other · Partial · Safety · 30 employees at the site · Closed Jan 22, 2019

4425 E. Fletcher Ave., Tampa, FL 33613 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1c
29 CFR 1926.454(a) · Scaffold training
Serious$0$4,527Dec 20, 2018Final
Citation 2, item 1
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Repeat$12,935$6,468Dec 20, 2018Final

Inspection 340993898 OPENED OCT 19, 2015Closed

Referral · Partial · Safety · 10 employees at the site · Closed Jan 5, 2016

410 Missouri Ave. N., Largo, FL 33770 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 339970196 OPENED SEP 26, 2014Closed

Complaint · Partial · Safety · 15 employees at the site · Closed Dec 5, 2014

12939 Cortez Blvd., Spring Hill, FL 34608 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(4)(iii) · Scaffolds, general requirements
Serious$2,800$1,680Oct 22, 2014Final
Citation 1, item 2
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$3,500$2,100Oct 22, 2014Final

Inspection 339565285 OPENED JAN 28, 2014Closed

Unprogrammed other · Complete · Safety · 13 employees at the site · Closed Jul 28, 2014

11209 Ranch Creek Terrace, Bradenton, FL 34211 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$2,100$1,050Apr 1, 2014Final
Citation 1, item 1b
29 CFR 1910.134(d)(1)(i) · Respiratory protection
Serious$0$0Apr 1, 2014Final
Citation 1, item 2
29 CFR 1910.1200(h)(3)(iv) · Hazard communication
Serious$2,100$1,050Apr 1, 2014Final
21 older inspections

Inspection 339121162 OPENED JUN 14, 2013Closed

Planned · Partial · Safety · 12 employees at the site · Closed Jul 10, 2013

600 Sawgrass Village Drive, Ponte Vedra Beach, FL 32082 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,975$1,785Jun 25, 2013Final

Inspection 338820236 OPENED FEB 7, 2013Closed

Planned · Partial · Safety · 14 employees at the site · Closed Nov 26, 2013

11411 Ulmerton Rd., Largo, FL 33778 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.502(g)(1) · Fall protection systems
Serious$3,080$3,080Feb 19, 2013Final

Inspection 313877615 OPENED JUN 29, 2010Closed

Planned · Complete · Safety · 5 employees at the site · Closed Aug 12, 2010

3449 S.w. State Road 26, Trenton, FL 32693 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(a)(2)(iii) · Job-site wiring
Other-than-serious$1,125$1,125Jul 30, 2010Closed

Inspection 313361875 OPENED MAY 11, 2009Closed

Planned · Partial · Safety · 17 employees at the site · Closed Jun 16, 2009

10 N. Corona, Clearwater, FL 33765 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$2,000$1,500Jun 3, 2009Closed

Inspection 311548036 OPENED AUG 28, 2007Closed

Planned · Partial · Safety · 170 employees at the site · Closed Oct 5, 2007

1015 Bruce B Downs Blvd, Tampa, FL 33543 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$4,000$3,000Sep 19, 2007Closed
Citation 1, item 2
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$4,000$3,000Sep 19, 2007Closed
Citation 2, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Repeat$8,000$6,000Sep 19, 2007Closed

Inspection 311043566 OPENED MAR 21, 2007Closed

Planned · Partial · Safety · 150 employees at the site · Closed Jul 3, 2007

W. Plaza 3rd St. N & 4th Ave. N., St. Petersburg, FL 33701 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 310357272 OPENED JUL 28, 2006Closed

Planned · Partial · Safety · 187 employees at the site · Closed Sep 12, 2006

2894 Providence Lakes Blvd., Brandon, FL 33511 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,600$1,200Aug 31, 2006Closed

Inspection 309323061 OPENED AUG 18, 2005Closed

Unprogrammed other · Partial · Safety · 30 employees at the site · Closed Oct 18, 2005

1042 Apollo Beach Blvd., Apollo Beach, FL 33572 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 307150771 OPENED MAR 25, 2004Closed

Unprogrammed other · Complete · Safety · 115 employees at the site · Closed Jul 29, 2004

5301 Clark Road, Sarasota, FL 34233 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$4,000$2,400Jun 22, 2004Closed
Citation 1, item 1b
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$0$0Jun 22, 2004Closed
Citation 1, item 1c
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$0$0Jun 22, 2004Closed
Citation 1, item 1d
29 CFR 1926.451(h)(2) · Scaffolds, general requirements
Serious$0$0Jun 22, 2004Closed
Citation 2, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Repeat$8,000$4,800Jun 22, 2004Closed
Citation 2, item 2a
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Repeat$16,000$9,600Jun 22, 2004Closed
Citation 2, item 2b
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Repeat$0$0Jun 22, 2004Closed
Citation 2, item 2c
29 CFR 1926.501(b)(1) · Fall protection in construction
Repeat$0$0Jun 22, 2004Closed

Inspection 306234766 OPENED FEB 5, 2003Closed

Unprogrammed other · Partial · Safety · 100 employees at the site · Closed Sep 10, 2003

1508 W. Brandon Blvd, Brandon, FL 33510 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Repeat$4,000$3,000Jul 15, 2003Closed
Citation 2, item 1
29 CFR 1926.28(a) · Personal protective equipment
Serious$675$506Jul 15, 2003Closed

Inspection 305136103 OPENED JAN 30, 2002Closed

Unprogrammed other · Complete · Safety · 11 employees at the site · Closed Jan 30, 2002

10500 W. Colonial, Ocoee, FL 34761 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 304517113 OPENED MAY 15, 2001Closed

Unprogrammed related · Partial · Safety · 15 employees at the site · Closed Sep 28, 2001

2535 60 East, Valrico, FL 33594 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,000$1,600Aug 31, 2001Closed
Citation 1, item 2
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,000$1,600Aug 31, 2001Closed

Inspection 304030802 OPENED JAN 25, 2001Closed

Unprogrammed related · Complete · Safety · 4 employees at the site · Closed Feb 12, 2001

7949 Gunn Hwy, Tampa, FL 33626 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 302821038 OPENED AUG 18, 1999Closed

Complaint · Partial · Safety · 8 employees at the site · Closed Oct 7, 1999

18102 Bruce B. Downs, Tampa, FL 33647 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 109206540 OPENED FEB 5, 1998Closed

Referral · Complete · Safety · 21 employees at the site · Closed Mar 13, 1998

1701 North Blvd., Tampa, FL 33607 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$875$875Feb 25, 1998Closed

Inspection 109013623 OPENED JUN 20, 1995Closed

Planned · Complete · Safety · 17 employees at the site · Closed Aug 18, 1995

4150 Tamiami Trail, S. Venice, FL 34293 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$900$900Jul 18, 1995Closed
Citation 1, item 1b
29 CFR 1926.1053(b)(5)(i) · Ladders in construction
Serious$0$0Jul 18, 1995Closed
Citation 2, item 1
29 CFR 1926.451(a)(13) · Scaffolds, general requirements
Repeat$4,200$4,200Jul 18, 1995Closed
Citation 2, item 2
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Repeat$2,400$2,400Jul 18, 1995Closed
Citation 3, item 1
29 CFR 1926.20(b)(1) · Construction safety programs
Other-than-serious$0$0Jul 18, 1995Closed
Citation 3, item 2
29 CFR 1926.451(d)(7) · Scaffolds, general requirements
Other-than-serious$0$0Jul 18, 1995Closed

Inspection 109608299 OPENED MAY 26, 1994Closed

Unprogrammed related · Complete · Safety · 14 employees at the site · Closed Jul 28, 1994

459 Brandon Town Center Mall, Brandon, FL 33511 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.59(f)(5)(ii) · Hazard communication
Other-than-serious$0$0Jul 20, 1994Closed
Citation 1, item 2
29 CFR 1926.152(g)(11) · Flammable liquids
Other-than-serious$0$0Jul 20, 1994Closed

Inspection 109687236 OPENED SEP 1, 1993Closed

Referral · Complete · Safety · 30 employees at the site · Closed Jan 11, 1994

5006 Airport Rd., Naples, FL 33940 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(a)(13) · Scaffolds, general requirements
Serious$1,575$800Nov 23, 1993Closed
Citation 1, item 2
29 CFR 1926.451(d)(3) · Scaffolds, general requirements
Serious$1,575$850Nov 23, 1993Closed
Citation 1, item 3
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Serious$1,575$850Nov 23, 1993Closed

Inspection 102963378 OPENED MAR 20, 1991Closed

Unprogrammed related · Complete · Safety · 20 employees at the site · Closed Jun 25, 1991

14902 North Dale Mabry Hwy, Tampa, FL 33618 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(a)(3) · Scaffolds, general requirements
Serious$1,225$665May 28, 1991Closed
Citation 1, item 2
29 CFR 1926.451(a)(4) · Scaffolds, general requirements
Serious$1,225$665May 28, 1991Closed
Citation 1, item 3
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Serious$1,225$665May 28, 1991Closed

Inspection 106385867 OPENED JAN 16, 1991Closed

Planned · Complete · Safety · 8 employees at the site · Closed Mar 6, 1991

4210 S. Dale Mabry Hwy, Tampa, FL 33611 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.59(e)(1) · Hazard communication
Serious$180$180Feb 8, 1991Closed
Citation 1, item 2
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$300$300Feb 8, 1991Closed
Citation 1, item 3a
29 CFR 1926.350(a)(9) · Gas welding and cutting
Serious$240$240Feb 8, 1991Closed
Citation 1, item 3b
29 CFR 1926.350(j) · Gas welding and cutting
Serious$0$0Feb 8, 1991Closed
Citation 2, item 1
29 CFR 1926.20(b)(1) · Construction safety programs
Other-than-serious$0$0Feb 8, 1991Closed

Inspection 106208390 OPENED DEC 3, 1990Closed

Unprogrammed related · Complete · Safety · 6 employees at the site · Closed Jan 31, 1991

5901 E. Fowler Avenue, Temple Terrace, FL 33617 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.152(e)(4) · Flammable liquids
Serious$200$200Jan 14, 1991Closed
Citation 1, item 2
29 CFR 1926.451(a)(13) · Scaffolds, general requirements
Serious$300$300Jan 14, 1991Closed
Citation 1, item 3
29 CFR 1926.451(d)(7) · Scaffolds, general requirements
Serious$300$300Jan 14, 1991Closed
Citation 2, item 1
29 CFR 1903.2(a)(1) · Posting of notice; availability of the Act, regulations and applicable standards
Other-than-serious$50$50Jan 14, 1991Closed
Citation 2, item 2
29 CFR 1926.200(b)(1) · Accident prevention signs and tags
Other-than-serious$0$0Jan 14, 1991Closed
Citation 2, item 3
29 CFR 1926.59(e)(1) · Hazard communication
Other-than-serious$0$0Jan 14, 1991Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Tampa site logged 1 recordable injury or illness among about 99 workers: 1.4 per 100 full-time workers, against a median of 2.8 for its industry. Those cases cost 42 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Masonry Builders, Inc.
Tampa · 2025
99 111.42.8
masonry builders inc.
Tampa · 2022
110 645.32.8

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 4 reports on file.

Sep 6, 2022, Sarasota: Hospitalization · fractures · multiple trunk locations

An employee was washing down a brick wall. He was removing scaffolding and was about to move down to a lower level when he fell, landing on the ground about 20 feet below and suffering a hip and spine fracture.

Sep 20, 2019, Tampa: Hospitalization · fractures and dislocations · ankle(s)

An employee was bending down, reaching through a tower frame for a work platform to bind straps and frames together in preparation for shipping. The frame flipped over and landed on his left ankle, dislocating and fracturing it. He was hospitalized.

Nov 12, 2018, Lakewood Ranch: Hospitalization · fractures · multiple body parts, n.e.c.

An employee was dismantling scaffold that was three frames high and had planking that was three planks wide. As he was dismantling the ladder portion, the ladder tipped forward and he lost his balance and fell 18 feet to the ground, suffering a left heel fracture, a right ankle fracture and compression of numbers 1, 2 and 3 vertebrae.

Sep 21, 2018, Parrish: Hospitalization · fractures · skull

An employee fell off a roof and fractured his skull, requiring hospitalization.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.2 · Posting of notice; availability of the Act, regulations and applicable standards

29 CFR 1903.2(a)(1)

(a)(1) Each employer shall post and keep posted a notice or notices, to be furnished by the Occupational Safety and Health Administration, U.S. Department of Labor, informing employees of the protections and obligations provided for in the Act, and that for assistance and information, including copies of the Act and of specific safety and health standards, employees should contact the employer or the nearest office of the Department of Labor. Such notice or notices shall be posted by the employer in each establishment in a conspicuous place or places where notices to employees are customarily posted. Each employer shall take steps to insure that such notices are not altered, defaced, or covered by other material.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(h)(3)(iv)

(iv) The details of the hazard communication program developed by the employer, including an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employees can obtain and use the appropriate hazard information.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.152 · Flammable liquids

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.200 · Accident prevention signs and tags

29 CFR 1926.28 · Personal protective equipment

29 CFR 1926.350 · Gas welding and cutting

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.59 · Hazard communication

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

Other masonry contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.