OSHA SearchOSHA records by employer

Master Coating Technologies LLC: OSHA inspections and violations

Eagan, Minnesota · Paint and Coating Manufacturing · NAICS 325510

4inspections
15citation items
$4,940current penalties
Jul 21, 2016last inspection

OSHA has inspected Master Coating Technologies LLC 4 times in Minnesota since 1997.

The latest one began on Jul 21, 2016 as a planned inspection, in Saint Paul.

Those inspections ended with 15 citation items: 10 serious and 5 other-than-serious.

Penalties were first proposed at $5,700 and now stand at $4,940, 13% lower after settlements or reviews.

Respiratory protection comes up most often in these citations: 3 items under 1910.134.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Master Coating Technologies LLC averages $3,150 (1 cited inspection).

Master Coating Technologies LLC: OSHA citation items per year, 1997 to 2016
Citation items per year, by inspection date.

Want to know if OSHA cites Master Coating Technologies LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 341636223 OPENED JUL 21, 2016Closed

Planned · Complete · Health · 25 employees at the site · Closed Jan 24, 2017

2777 Eagandale Boulevard, Saint Paul, MN 55121 · Paint and Coating Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(c)(5) · Spray painting and finishing
Serious$750$750Aug 15, 2016Final
Citation 1, item 2
29 CFR 1910.107(g)(2) · Spray painting and finishing
Serious$450$450Aug 15, 2016Final
Citation 1, item 3
29 CFR 1910.134(a)(2) · Respiratory protection
Serious$600$600Aug 15, 2016Final
Citation 1, item 4
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$450$450Aug 15, 2016Final
Citation 1, item 5
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$600$600Aug 15, 2016Final
Citation 2, item 1
29 CFR 1910.178(l) · Forklifts and other powered industrial trucks
Other-than-serious$150$150Aug 15, 2016Final
Citation 2, item 2
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$150$150Aug 15, 2016Final

Inspection 316285808 OPENED JAN 31, 2012Closed

Planned · Complete · Health · 21 employees at the site · Closed Mar 13, 2012

2777 Eagandale Boulevard, Eagan, MN 55121 · Paint and Coating Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$500$500Feb 21, 2012Closed
Citation 2, item 1 Other-than-serious$100$100Feb 21, 2012Closed

Inspection 313590671 OPENED JUL 17, 2009Closed

Planned · Complete · Safety · 23 employees at the site · Closed Sep 29, 2009

2777 Eagandale Boulevard, Eagan, MN 55121 · Paint and Coating Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Other-than-serious$100$70Sep 3, 2009Closed
Citation 1, item 2 Other-than-serious$100$70Sep 3, 2009Closed

Inspection 300364213 OPENED JAN 24, 1997Closed

Complaint · Partial · Health · 7 employees at the site · Closed Oct 2, 1997

3670 Dodd Rd, Eagan, MN 55123 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(a)(2) · Respiratory protection
Serious$500$262Feb 18, 1997Final
Citation 1, item 2
29 CFR 1910.151(c) · First aid and eyewash
Serious$500$264Feb 18, 1997Final
Citation 1, item 3
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Serious$375$262Feb 18, 1997Final
Citation 1, item 4 Serious$375$262Feb 18, 1997Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(c)(5)

(5) Combustible residues, areas. Unless specifically approved for locations containing both deposits of readily ignitable residue and explosive vapors, there shall be no electrical equipment in any spraying area, whereon deposits of combustible residues may readily accumulate, except wiring in rigid conduit or in boxes or fittings containing no taps, splices, or terminal connections.

29 CFR 1910.107(g)(2)

(2) Cleaning. All spraying areas shall be kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary. Scrapers, spuds, or other such tools used for cleaning purposes shall be of nonsparking material.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(h)(1)

(h) Employee information and training. (1) Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 5205.116

29 CFR 5205.870

29 CFR 5206.700

Other paint and coating manufacturing employers in Minnesota