Master Lock Company LLC: OSHA inspections and violations
Milwaukee, Wisconsin · All Other Miscellaneous Fabricated Metal Product Manufacturing · NAICS 332999
24inspections
35citation items
$18,360current penalties
Jul 26, 2021last inspection
OSHA has inspected Master Lock Company LLC 24 times in Wisconsin since 1973.
The latest one began on Jul 26, 2021 after a fatality or catastrophe, in Milwaukee.
Those inspections ended with 35 citation items: 9 serious, 2 repeat and 24 other-than-serious.
Penalties were first proposed at $34,936 and now stand at $18,360, 47% lower after settlements or reviews.
Woodworking machinery comes up most often in these citations: 3 items under 1910.213.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Master Lock Company LLC averages $4,025 (1 cited inspection).
1 inspection on this page followed a fatal incident.
Master Lock Company LLC also files yearly injury logs with OSHA, summarized below.
It reported 2 severe injuries to OSHA since 2015.
Citation items per year, by inspection date.
Wisconsin · latest 90 days of OSHA records
223employers cited
4 of them in the same industry
Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.
Incident on Jul 20, 2021 (fatal): Employee dies while on break
At 11:30 p.m. on July 20, 2021, an employee finished working and went to the break room for a coffee. The employee was found slumped over in a seat at a table and was not responsive. The employee was unable to be revived and pronounced dead.
No citations from this inspection.
Inspection 344064472 OPENED JUN 7, 2019Closed
Referral · Partial · Safety · 450 employees at the site · Closed Oct 31, 2019
Incident on Jun 5, 2019: Employee amputates finger while operating pneumatic press
At 3:30 p.m. on June 5, 2019, an employee was operating a pneumatic press when her finger was caught between pneumatic cylinder housing and the ram. The employee suffered an amputation of her right index finger at the second joint but was not hospitalized.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2023, the Milwaukee site logged 12 recordable injuries or illnesses among about 325 workers: 3.6 per 100 full-time workers, against a median of 2.7 for its industry. Those cases cost 92 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
The Master Lock Company
Milwaukee · 2023
325
12
2
3.6
2.7
Master Lock Company LLC Milwaukee Facility
Milwaukee · 2019
439
25
5
5.6
2.7
Included with any plan: 3 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.
(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra
(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.
29 CFR 1910.120 · Hazardous waste operations and emergency response
Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.