OSHA SearchOSHA records by employer

McWhirter Wood Products: OSHA inspections and violations

Houston, Texas · All Other Miscellaneous Wood Product Manufacturing · NAICS 321999

2inspections
11citation items
$13,955current penalties
Aug 28, 2024last inspection

McWhirter Wood Products has 2 OSHA inspections on record in Texas, the first in 1995.

OSHA's last visit started on Aug 28, 2024 as a planned inspection, in Houston.

Across those inspections OSHA issued 11 citation items: 6 serious and 5 other-than-serious.

OSHA proposed $23,394 in penalties. After settlements and reviews the total is $13,955, down 40%.

Most often, OSHA cited 1910.134, respiratory protection (3 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. McWhirter Wood Products averages $13,550 over 1 cited inspection in that time.

McWhirter Wood Products: OSHA citation items per year, 1995 to 2024
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

394employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch McWhirter Wood Products and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347717530 OPENED AUG 28, 2024Closed

Planned · Complete · Safety · 34 employees at the site · Closed Jan 13, 2025

5815 Schuler Street, Houston, TX 77007 · All Other Miscellaneous Wood Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$11,292$6,775Nov 13, 2024Final
Citation 1, item 2
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$11,292$6,775Nov 13, 2024Final

Inspection 122262561 OPENED JUL 27, 1995Closed

Planned · Complete · Health · 14 employees at the site · Closed Aug 21, 1995

5815 Schuler Street, Houston, TX 77007 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Serious$405$200Aug 9, 1995Closed
Citation 1, item 1b
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Serious$0$0Aug 9, 1995Closed
Citation 1, item 2a
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$405$205Aug 9, 1995Closed
Citation 1, item 2b
29 CFR 1910.107(g)(2) · Spray painting and finishing
Serious$0$0Aug 9, 1995Closed
Citation 2, item 1
29 CFR 1910.134(b)(1) · Respiratory protection
Other-than-serious$0$0Aug 9, 1995Closed
Citation 2, item 2
29 CFR 1910.134(b)(3) · Respiratory protection
Other-than-serious$0$0Aug 9, 1995Closed
Citation 2, item 3
29 CFR 1910.134(c) · Respiratory protection
Other-than-serious$0$0Aug 9, 1995Closed
Citation 2, item 4
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Aug 9, 1995Closed
Citation 2, item 5
29 CFR 1910.1200(h) · Hazard communication
Other-than-serious$0$0Aug 9, 1995Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(g)(2)

(2) Cleaning. All spraying areas shall be kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary. Scrapers, spuds, or other such tools used for cleaning purposes shall be of nonsparking material.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

Other all other miscellaneous wood product manufacturing employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.