OSHA SearchOSHA records by employer

Midwest Masonry, Inc.: OSHA inspections and violations

Chicago, Illinois · Masonry Contractors · NAICS 238140

39inspections
73citation items
$232,746current penalties
Aug 24, 2023last inspection

Since 1990, OSHA inspectors have visited Midwest Masonry, Inc. in Illinois 39 times.

The most recent inspection opened on Aug 24, 2023 as a planned inspection, in Chicago.

In all, OSHA issued 73 citation items: 52 serious, 7 willful, 8 repeat and 6 other-than-serious.

The proposed penalties came to $538,521; today they stand at $232,746, 57% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 37 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Midwest Masonry, Inc. averages $5,371 across 1 cited inspection.

1 inspection on this page followed a fatal incident.

Midwest Masonry, Inc. also files yearly injury logs with OSHA, summarized below.

Midwest Masonry, Inc.: OSHA citation items per year, 1990 to 2023
Citation items per year, by inspection date.

Illinois · latest 90 days of OSHA records

416employers cited

11 of them in the same industry

Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Illinois

Checking a subcontractor, a client or your own company? Watch Midwest Masonry, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346936263 OPENED AUG 24, 2023Closed

Planned · Partial · Safety · 15 employees at the site · Closed Dec 13, 2023

812 West Adams, Chicago, IL 60607 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 346937626 OPENED AUG 24, 2023Closed

Planned · Partial · Health · 15 employees at the site · Closed Sep 8, 2023

812 W. Adams St., Chicago, IL 60607 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344286927 OPENED SEP 3, 2019Closed

Planned · Partial · Safety · 9 employees at the site · Closed Jul 10, 2020

20 W. Northwest Hwy, Mount Prospect, IL 60056 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$10,741$5,371Nov 19, 2019Final

Inspection 341436632 OPENED APR 28, 2016Closed

Planned · Partial · Safety · 6 employees at the site · Closed Jul 13, 2016

255 Addison Ave., Elmhurst, IL 60126 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 330628934 OPENED MAY 24, 2011Closed

Planned · Partial · Safety · 25 employees at the site · Closed May 25, 2011

3035 W. 163rd St., Markham, IL 60428 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 313932493 OPENED FEB 2, 2010Closed

Planned · Complete · Safety · 10 employees at the site · Closed Apr 15, 2010

20642 Matteson Ave, Matteson, IL 60443 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Other-than-serious$3,000$0Mar 23, 2010Closed

Inspection 311374680 OPENED JUN 11, 2008Closed

Unprogrammed other · Partial · Safety · 20 employees at the site · Closed Aug 15, 2008

20900 South Matteson Ave., Matteson, IL 60443 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(9)(i) · Fall protection in construction
Serious$6,000$3,000Jul 14, 2008Closed

Inspection 310171095 OPENED SEP 15, 2006Closed

Planned · Complete · Safety · 20 employees at the site · Closed May 18, 2007

1315 West Exchange Ave, Crete, IL 60417 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$6,000$3,000Jan 25, 2007Final
31 older inspections

Inspection 308790104 OPENED APR 28, 2005Closed

Unprogrammed related · Partial · Safety · 8 employees at the site · Closed Jun 27, 2005

50 N. Plum Grove Road, Palatine, IL 60067 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$4,000$2,000May 31, 2005Closed
Citation 1, item 1b
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$0$0May 31, 2005Closed
Citation 1, item 1c
29 CFR 1926.502(i)(3) · Fall protection systems
Serious$0$0May 31, 2005Closed

Inspection 308148089 OPENED JAN 4, 2005Closed

Planned · Partial · Health · 8 employees at the site · Closed Jan 10, 2005

1500 S. Randall Rd., Algonquin, IL 60012 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 307367904 OPENED MAY 5, 2004Closed

Planned · Partial · Safety · 60 employees at the site · Closed May 26, 2004

243 North Parkside, Chicago, IL 60644 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 305160855 OPENED MAY 8, 2003Closed

Unprogrammed other · Partial · Safety · 16 employees at the site · Closed Jun 25, 2003

1300 Sycamore Road, Sycamore, IL 60115 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(h)(2)(i) · Scaffolds, general requirements
Other-than-serious$1,400$1,000May 14, 2003Closed

Inspection 304781883 OPENED OCT 25, 2001Closed

Referral · Partial · Safety · 2 employees at the site · Closed Jan 22, 2002

Crawford & Devon, Lincolnwood, IL 60123 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 302604848 OPENED JAN 7, 2000Closed

Referral · Partial · Safety · 6 employees at the site · Closed Sep 5, 2003

1300 Sycamore Road, Sycamore, IL 60115 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$4,000$1,750May 3, 2000Closed
Citation 1, item 2
29 CFR 1926.451(c)(1) · Scaffolds, general requirements
Serious$4,000$1,750May 3, 2000Closed
Citation 1, item 3
29 CFR 1926.451(c)(2)(v) · Scaffolds, general requirements
Serious$4,000$1,750May 3, 2000Closed
Citation 1, item 4
29 CFR 1926.451(e)(9)(i) · Scaffolds, general requirements
Serious$4,000$1,750May 3, 2000Closed
Citation 2, item 1a
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Willful$63,000$22,000May 3, 2000Closed
Citation 2, item 1b
29 CFR 1926.451(g)(2) · Scaffolds, general requirements
Willful$0$0May 3, 2000Closed
Citation 2, item 2
29 CFR 1926.706(b) · Requirements for masonry construction
Willful$49,500$17,000May 3, 2000Closed
Citation 3, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$28,000$7,000May 3, 2000Closed

Inspection 302603964 OPENED OCT 18, 1999Closed

Planned · Partial · Safety · 6 employees at the site · Closed Nov 2, 2004

501 Randall Road, Batavia, IL 60501 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$4,000$1,150Apr 14, 2000Final
Citation 1, item 2
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$2,800$900Apr 14, 2000Final
Citation 1, item 3
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Serious$4,000$1,150Apr 14, 2000Final
Citation 1, item 4
29 CFR 1926.451(e)(9)(i) · Scaffolds, general requirements
Serious$2,800$900Apr 14, 2000Final
Citation 1, item 5
29 CFR 1926.451(g)(2) · Scaffolds, general requirements
Serious$2,800$900Apr 14, 2000Final
Citation 2, item 1
29 CFR 1926.451(c)(1)(ii) · Scaffolds, general requirements
Willful$63,000$22,000Apr 14, 2000Final
Citation 3, item 1
29 CFR 1926.50(g) · Medical services and first aid
Repeat$3,200$2,000Apr 14, 2000Final
Citation 3, item 2
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Repeat$8,000$3,000Apr 14, 2000Final
Citation 3, item 3
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Repeat$14,000$4,500Apr 14, 2000Final
Citation 3, item 4
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Repeat$28,000$8,000Apr 14, 2000Final
Citation 3, item 5
29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements
Repeat$5,600$2,500Apr 14, 2000Final

Inspection 302901137 OPENED AUG 3, 1999Closed

Planned · Partial · Safety · 20 employees at the site · Closed Oct 26, 1999

750 E Rand Road, Mount Prospect, IL 60056 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(f)(6) · Scaffolds, general requirements
Serious$3,000$2,000Aug 23, 1999Closed

Inspection 302763263 OPENED JUN 9, 1999Closed

Planned · Partial · Safety · 8 employees at the site · Closed Jun 9, 1999

Pointe Plaza Project, Niles, IL 60714 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 302675897 OPENED MAY 18, 1999Closed

Planned · Partial · Safety · 16 employees at the site · Closed May 18, 1999

335 Milwaukee Ave., Vernon Hills, IL 60061 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 302675814 OPENED MAY 10, 1999Closed

Planned · Partial · Safety · 25 employees at the site · Closed May 10, 1999

230 E. Rollins Rd., Round Lake Beach, IL 60073 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 302675830 OPENED MAY 10, 1999Closed

Planned · No inspection · Safety · Closed May 10, 1999

1940 Hook Dr., Round Lake Beach, IL 60073 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 302675699 OPENED MAY 4, 1999Closed

Planned · Partial · Safety · 30 employees at the site · Closed May 4, 1999

145 N. Lakeview, Vernon Hills, IL 60061 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 302675095 OPENED MAR 30, 1999Closed

Unprogrammed related · Complete · Safety · 5 employees at the site · Closed Sep 22, 1999

Greater Round Lake Area Post Office, Round Lake, IL 60073 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 302041538 OPENED MAY 11, 1998Closed

Planned · Partial · Safety · 4 employees at the site · Closed Sep 22, 2000

2002 Golf Mill Center, Niles, IL 60714 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$1,200$800Aug 21, 1998Final
Citation 2, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Willful$44,000$27,600Aug 21, 1998Final
Citation 3, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Repeat$2,400$1,600Aug 21, 1998Final

Inspection 113455414 OPENED AUG 28, 1997Closed

Planned · Partial · Safety · 10 employees at the site · Closed Oct 1, 1997

28250 Diehl Road, Warrenville, IL 60555 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 300585320 OPENED APR 24, 1997Closed

Planned · Partial · Safety · 20 employees at the site · Closed Apr 28, 1997

Algonquin / Randall Rd, Lake In The Hill, IL 60102 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 300948577 OPENED FEB 19, 1997Closed

Planned · Partial · Safety · 6 employees at the site · Closed Dec 1, 1997

140 & 160 E. Roselle Road, Schaumburg, IL 60194 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$765$765Mar 4, 1997Closed
Citation 2, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Repeat$7,500$7,500Mar 4, 1997Closed

Inspection 300584208 OPENED JAN 21, 1997Closed

Planned · Partial · Safety · 12 employees at the site · Closed Feb 4, 1997

Algonquin / Randall Rd, Lake In The Hill, IL 60102 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 300582533 OPENED MAY 24, 1996Closed

Planned · Complete · Safety · 10 employees at the site · Closed Nov 23, 1998

2215 West 22nd Street, Oak Brook, IL 60521 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.20(b)(1) · Construction safety programs
Serious$3,000$1,500Nov 7, 1996Closed
Citation 1, item 1b
29 CFR 1926.21(b)(2) · Construction safety training
Serious$0$0Nov 7, 1996Closed
Citation 1, item 2
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$3,000$1,500Nov 7, 1996Closed
Citation 1, item 3
29 CFR 1926.50(g) · Medical services and first aid
Serious$2,100$1,050Nov 7, 1996Closed
Citation 1, item 4
29 CFR 1926.451(a)(8) · Scaffolds, general requirements
Serious$3,000$1,500Nov 7, 1996Closed
Citation 1, item 5
29 CFR 1926.451(a)(13) · Scaffolds, general requirements
Serious$3,000$1,500Nov 7, 1996Closed
Citation 1, item 6
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$3,000$1,500Nov 7, 1996Closed
Citation 1, item 7
29 CFR 1926.702(j)(1) · Requirements for equipment and tools
Serious$3,000$1,500Nov 7, 1996Closed
Citation 1, item 8
29 CFR 1926.706(a)(1) · Requirements for masonry construction
Serious$1,500$750Nov 7, 1996Closed
Citation 2, item 1a
29 CFR 1926.706(b) · Requirements for masonry construction
Willful$56,000$28,000Nov 7, 1996Closed
Citation 2, item 1b
OSH Act Section 5(a)(1) · General Duty Clause
Repeat$0$0Nov 7, 1996Closed
Citation 2, item 2
29 CFR 1926.451(a)(4) · Scaffolds, general requirements
Willful$40,000$20,000Nov 7, 1996Closed
Citation 3, item 1
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$0$0Nov 7, 1996Closed
Citation 3, item 2
29 CFR 1926.59(g)(8) · Hazard communication
Other-than-serious$0$0Nov 7, 1996Closed
Citation 3, item 3
29 CFR 1926.59(h) · Hazard communication
Other-than-serious$0$0Nov 7, 1996Closed

Inspection 122279284 OPENED OCT 23, 1995Closed

Accident · Complete · Safety · 14 employees at the site · Closed Nov 8, 1996

243 North Parkside, Chicago, IL 60644 · OSHA's record · Phone and website on Google Maps

Incident on Oct 23, 1995 (fatal): Employees killed in fall from scaffold

Employees #1 and #2 were working from a Morgan scaffold 24 ft above ground erect ing a 28 ft tall cinderblock wall with six other employees. The wall was not ade quately braced and collapsed when 37 mph wind gusts pushed the wall down. Employ ees #1 and #2 fell to the ground and were struck by the falling bricks. They wer e killed.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
OSH Act Section 5(a)(1) · General Duty Clause
Serious$7,000$3,500Apr 3, 1996Closed
Citation 1, item 1b
29 CFR 1926.706(b) · Requirements for masonry construction
Serious$0$0Apr 3, 1996Closed
Citation 1, item 2
29 CFR 1926.451(a)(23) · Scaffolds, general requirements
Serious$7,000$3,500Apr 3, 1996Closed

Inspection 103593513 OPENED OCT 10, 1995Closed

Planned · Partial · Safety · 5 employees at the site · Closed Nov 21, 1995

1232 W. North Avenue, Chicago, IL 60622 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Serious$1,250$1,250Oct 19, 1995Closed

Inspection 122103757 OPENED SEP 15, 1994Closed

Complaint · Complete · Safety · 26 employees at the site · Closed Sep 16, 1994

501 Randall Road, Batavia, IL 60501 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 103305637 OPENED OCT 23, 1991Closed

Planned · Complete · Safety · 4 employees at the site · Closed Jan 4, 1994

3205 60th Street, Moline, IL 61265 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.59(e)(1) · Hazard communication
Serious$750$525Nov 1, 1991Closed
Citation 1, item 2
29 CFR 1926.300(b)(2) · Tools—Hand and Power: general requirements
Serious$600$420Nov 1, 1991Closed
Citation 1, item 3
29 CFR 1926.304(f) · Woodworking tools
Serious$750$525Nov 1, 1991Closed

Inspection 103073201 OPENED AUG 20, 1991Closed

Planned · Complete · Safety · 8 employees at the site · Closed Feb 6, 1992

Mark Twain Elementary School, Wheeling, IL 60090 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$675$450Sep 20, 1991Closed
Citation 1, item 1b
29 CFR 1926.404(f)(7)(ivc) · Ground-fault protection on job sites
Serious$0$0Sep 20, 1991Closed

Inspection 103071148 OPENED MAY 2, 1991Closed

Referral · Complete · Safety · 12 employees at the site · Closed Jan 24, 1992

Greater Round Lake Area Post Office, Round Lake, IL 60073 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$375$250Jun 10, 1991Closed

Inspection 103328613 OPENED APR 5, 1991Closed

Referral · Partial · Health · 2 employees at the site · Closed Mar 26, 1993

3139 North Lincoln Avenue, Chicago, IL 60657 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.59(e)(1) · Hazard communication
Serious$1,200$750Jul 18, 1991Final
Citation 1, item 2a
29 CFR 1926.200(a) · Accident prevention signs and tags
Serious$1,500$725Jul 18, 1991Final
Citation 1, item 2b
29 CFR 1926.200(i) · Accident prevention signs and tags
Serious$0$0Jul 18, 1991Final
Citation 1, item 3
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$1,200$725Jul 18, 1991Final
Citation 1, item 4
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$1,200$725Jul 18, 1991Final
Citation 1, item 5
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$3,000$725Jul 18, 1991Final
Citation 1, item 6
29 CFR 1926.451(e)(6) · Scaffolds, general requirements
Serious$1,200$725Jul 18, 1991Final
Citation 1, item 7
29 CFR 1926.451(e)(4) · Scaffolds, general requirements
Serious$1,500$725Jul 18, 1991Final
Citation 1, item 8
29 CFR 1926.451(e)(6) · Scaffolds, general requirements
Serious$1,500$725Jul 18, 1991Final
Citation 1, item 9
29 CFR 1926.451(e)(8) · Scaffolds, general requirements
Serious$1,500$725Jul 18, 1991Final
Citation 1, item 10
29 CFR 1926.451(e)(10) · Scaffolds, general requirements
Serious$1,500$725Jul 18, 1991Final
Citation 1, item 11
29 CFR 1926.951(b)(1) · Medical services and first aid
Serious$1,500$725Jul 18, 1991Final

Inspection 103068458 OPENED MAR 7, 1991Closed

Planned · Complete · Safety · 10 employees at the site · Closed Jul 2, 1991

200 Rockland Rd(rt 176)-water Treatment Facility, Lake Bluff, IL 60044 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.300(b)(2) · Tools—Hand and Power: general requirements
Serious$375$250Apr 9, 1991Closed

Inspection 103197471 OPENED JUL 26, 1990Closed

Unprogrammed other · Complete · Safety · 15 employees at the site · Closed Dec 10, 1990

Warrenville & North Mill Road, Naperville, IL 60540 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(a)(4) · Scaffolds, general requirements
Serious$640$640Aug 14, 1990Closed
Citation 2, item 1
29 CFR 1926.500(b)(2) · Scope, application, and definitions applicable to this subpart
Other-than-serious$0$0Aug 14, 1990Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Mundelein site logged 0 recordable injuries or illnesses among about 62 workers: 0.0 per 100 full-time workers, against a median of 2.8 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Midwest Masonry, Inc.
Mundelein · 2025
62 000.02.8

Included with any plan: 9 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.2 · Partial exemption for establishments in certain industries

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(1)

(b) Accident prevention responsibilities. (1) It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part.

29 CFR 1926.20(b)(2)

(2) Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.

29 CFR 1926.200 · Accident prevention signs and tags

29 CFR 1926.21 · Construction safety training

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.304 · Woodworking tools

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.50 · Medical services and first aid

29 CFR 1926.500 · Scope, application, and definitions applicable to this subpart

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.59 · Hazard communication

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

29 CFR 1926.702 · Requirements for equipment and tools

29 CFR 1926.706 · Requirements for masonry construction

29 CFR 1926.951 · Medical services and first aid

OSH Act Section 5 · General Duty Clause

Other masonry contractors employers in Illinois

Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.