OSHA SearchOSHA records by employer

Morrow Cabinets and Millworks: OSHA inspections and violations

Lewisville, Texas · Wood Kitchen Cabinet and Countertop Manufacturing · NAICS 337110

3inspections
8citation items
$12,376current penalties
Mar 22, 2017last inspection

OSHA has inspected Morrow Cabinets and Millworks 3 times in Texas since 2015.

The latest one began on Mar 22, 2017 to follow up on an earlier case, in Lewisville.

Those inspections ended with 8 citation items: 6 serious and 2 other-than-serious.

Penalties were first proposed at $20,626 and now stand at $12,376, 40% lower after settlements or reviews.

Electrical wiring methods comes up most often in these citations: 3 items under 1910.305.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Morrow Cabinets and Millworks averages $4,125 (3 cited inspections).

Morrow Cabinets and Millworks: OSHA citation items per year, 2015 to 2017
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

401employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Morrow Cabinets and Millworks and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342188380 OPENED MAR 22, 2017Closed

Follow-up · Partial · Safety · 48 employees at the site · Closed Apr 10, 2017

136 E. College St., Lewisville, TX 75057 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$5,926$3,556Mar 24, 2017Final

Inspection 341120020 OPENED DEC 14, 2015Closed

Complaint · Partial · Health · 40 employees at the site · Closed Jun 7, 2016

136 E. College St., Lewisville, TX 75057 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$3,500$2,100Apr 18, 2016Final
Citation 1, item 2
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$3,500$2,100Apr 18, 2016Final

Inspection 341025237 OPENED NOV 2, 2015Closed

Complaint · Partial · Safety · 30 employees at the site · Closed Dec 29, 2015

136 E. College St., Lewisville, TX 75057 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(d)(1) · General requirements
Serious$2,100$1,260Dec 15, 2015Final
Citation 1, item 2a
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$2,800$1,680Dec 15, 2015Final
Citation 1, item 2b
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$0$0Dec 15, 2015Final
Citation 1, item 3
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Serious$2,100$1,260Dec 15, 2015Final
Citation 2, item 1
29 CFR 1904.32(a)(2) · Yearly injury summary
Other-than-serious$700$420Dec 15, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.32 · Yearly injury summary

29 CFR 1904.32(a)(2)

(2) Create an annual summary of injuries and illnesses recorded on the OSHA 300 Log;

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.22 · General requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(b)(2)(i)

(2) Covers and canopies. (i) All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

29 CFR 1910.334 · Using electrical equipment

OSH Act Section 5 · General Duty Clause

Other wood kitchen cabinet and countertop manufacturing employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.