OSHA SearchOSHA records by employer

Mountain River Plumbing: OSHA inspections and violations

Pocatello, Idaho · Water and Sewer Line and Related Structures Construction · NAICS 237110

1inspections
6citation items
$5,976current penalties
May 10, 2017last inspection

Mountain River Plumbing has one OSHA inspection on record in Idaho.

OSHA opened it on May 10, 2017 on a referral, in Pocatello.

From that inspection OSHA issued 6 citation items: 6 serious.

OSHA proposed $5,976 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.652, trench protection (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Mountain River Plumbing averages $5,976 over 1 cited inspection in that time.

Mountain River Plumbing: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Idaho · latest 90 days of OSHA records

62employers cited

Get notified the morning OSHA posts each new citation in Idaho: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Idaho

Checking a subcontractor, a client or your own company? Watch Mountain River Plumbing and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342319449 OPENED MAY 10, 2017Closed

Referral · Partial · Safety · 3 employees at the site · Closed Mar 4, 2019

603 S 10th, Pocatello, ID 83202 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Serious$2,173$2,173May 17, 2017Final
Citation 1, item 2a
29 CFR 1926.651(j)(2) · Excavations
Serious$3,803$3,803May 17, 2017Final
Citation 1, item 2b
29 CFR 1926.651(k)(1) · Excavations
Serious$0$0May 17, 2017Final
Citation 1, item 2c
29 CFR 1926.652(a)(1) · Trench protection
Serious$0$0May 17, 2017Final
Citation 1, item 2d
29 CFR 1926.652(c)(2)(iii) · Trench protection
Serious$0$0May 17, 2017Final
Citation 1, item 2e
29 CFR 1926.652(g)(1)(ii) · Trench protection
Serious$0$0May 17, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.651(j)(2)

(2) Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.

29 CFR 1926.651(k)(1)

(k) Inspections. (1) Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.

29 CFR 1926.652 · Trench protection

Other water and sewer line and related structures construction employers in Idaho

Alert subscribers get notified of each newly cited employer in Idaho the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.