OSHA SearchOSHA records by employer

National Roof Coaters LLC: OSHA inspections and violations

St. Albans, West Virginia · Roofing Contractors · NAICS 238160

3inspections
17citation items
$3,508current penalties
Feb 14, 2019last inspection

OSHA has inspected National Roof Coaters LLC 3 times in West Virginia since 1988.

The latest one began on Feb 14, 2019 as a planned inspection, in Ona.

Those inspections ended with 17 citation items: 14 serious and 3 other-than-serious.

Penalties were first proposed at $5,020 and now stand at $3,508, 30% lower after settlements or reviews.

Spray painting and finishing comes up most often in these citations: 4 items under 1910.107.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and National Roof Coaters LLC averages $2,558 (1 cited inspection).

National Roof Coaters LLC: OSHA citation items per year, 1988 to 2019
Citation items per year, by inspection date.

West Virginia · latest 90 days of OSHA records

27employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in West Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in West Virginia

Checking a subcontractor, a client or your own company? Watch National Roof Coaters LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343786075 OPENED FEB 14, 2019Closed

Planned · Partial · Safety · 4 employees at the site · Closed Jun 6, 2019

3254 U.s. Route 60, Ona, WV 25545 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$3,410$2,558Mar 28, 2019Final

Inspection 341819522 OPENED OCT 6, 2016Closed

Complaint · Partial · Safety · 20 employees at the site · Closed Oct 12, 2016

1266 Greenbrier Street, Charleston, WV 25311 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 720623 OPENED SEP 7, 1988Closed

Complaint · Complete · Safety · 35 employees at the site · Closed Nov 1, 1988

1018 Oliver Street, St. Albans, WV 25177 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.106(d)(2)(iii) · Flammable liquids
Serious$280$160Sep 20, 1988Closed
Citation 1, item 1b
29 CFR 1910.106(d)(3)(ii) · Flammable liquids
Serious$0$0Sep 20, 1988Closed
Citation 1, item 2a
29 CFR 1910.107(c)(5) · Spray painting and finishing
Serious$280$160Sep 20, 1988Closed
Citation 1, item 2b
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$0$0Sep 20, 1988Closed
Citation 1, item 2c
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$0$0Sep 20, 1988Closed
Citation 1, item 2d
29 CFR 1910.107(d)(2) · Spray painting and finishing
Serious$0$0Sep 20, 1988Closed
Citation 1, item 3
29 CFR 1910.212(a)(1) · Machine guarding
Serious$210$150Sep 20, 1988Closed
Citation 1, item 4a
29 CFR 1910.215(a)(1) · Grinders and abrasive wheels
Serious$280$160Sep 20, 1988Closed
Citation 1, item 4b
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Sep 20, 1988Closed
Citation 1, item 5a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$280$160Sep 20, 1988Closed
Citation 1, item 5b
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Sep 20, 1988Closed
Citation 1, item 6a
29 CFR 1910.252(a)(2)(iib) · Welding fire safety
Serious$280$160Sep 20, 1988Closed
Citation 1, item 6b
29 CFR 1910.252(a)(2)(ivc) · Welding fire safety
Serious$0$0Sep 20, 1988Closed
Citation 2, item 1
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Other-than-serious$0$0Sep 20, 1988Closed
Citation 2, item 2
29 CFR 1910.305(a)(2)(iiig) · Electrical wiring methods
Other-than-serious$0$0Sep 20, 1988Closed
Citation 2, item 3
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Sep 20, 1988Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(2)(iii)

(iii) Size. Flammable liquid containers shall be in accordance with Table H-12, except that glass or plastic containers of no more than 1-gallon capacity may be used for a Category 1 or 2 flammable liquid if:

29 CFR 1910.106(d)(3)(ii)

(ii) Fire resistance. Storage cabinets shall be designed and constructed to limit the internal temperature to not more than 325 °F. when subjected to a 10-minute fire test using the standard time-temperature curve as set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969, which is incorporated by reference as specified in § 1910.6. All joints and seams shall remain tight and the door shall remain securely closed during the fire test. Cabinets shall be labeled in conspicuous lettering, “Flammable—Keep Fire Away.”

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(c)(5)

(5) Combustible residues, areas. Unless specifically approved for locations containing both deposits of readily ignitable residue and explosive vapors, there shall be no electrical equipment in any spraying area, whereon deposits of combustible residues may readily accumulate, except wiring in rigid conduit or in boxes or fittings containing no taps, splices, or terminal connections.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1926.501 · Fall protection in construction

Other roofing contractors employers in West Virginia

Alert subscribers get notified of each newly cited employer in West Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.