OSHA SearchOSHA records by employer

Nautic Star, LLC: OSHA inspections and violations

Amory, Mississippi · Boat Building · NAICS 336612

4inspections
24citation items
$45,000current penalties
Aug 23, 2016last inspection

Nautic Star, LLC has 4 OSHA inspections on record in Mississippi, the first in 2016.

OSHA's last visit started on Aug 23, 2016 to follow up on an earlier case, in Amory.

Across those inspections OSHA issued 24 citation items: 16 serious and 8 other-than-serious.

OSHA proposed $66,105 in penalties. After settlements and reviews the total is $45,000, down 32%.

Most often, OSHA cited 1910.107, spray painting and finishing (6 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Nautic Star, LLC averages $22,500 over 2 cited inspections in that time.

It reported 1 severe injury to OSHA since 2015.

Nautic Star, LLC: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Mississippi · latest 90 days of OSHA records

16employers cited

Get notified the morning OSHA posts each new citation in Mississippi: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Mississippi

Checking a subcontractor, a client or your own company? Watch Nautic Star, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341724755 OPENED AUG 23, 2016Closed

Follow-up · Partial · Health · 200 employees at the site · Closed Feb 21, 2017

500 Waterway Drive, Amory, MS 38821 · Boat Building · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341680023 OPENED JUL 22, 2016Closed

Monitoring · Complete · Safety · 220 employees at the site · Closed Sep 8, 2016

500 Waterway Drive, Amory, MS 38821 · Boat Building · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341231827 OPENED FEB 5, 2016Closed

Referral · Partial · Health · 200 employees at the site · Closed Jun 29, 2016

500 Waterway Drive, Amory, MS 38821 · Boat Building · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$2,295$1,560Jun 1, 2016Final
Citation 1, item 2
29 CFR 1910.134(g)(1)(i)(a) · Respiratory protection
Serious$2,295$1,560Jun 1, 2016Final
Citation 2, item 1
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Other-than-serious$0$0Jun 1, 2016Final
Citation 2, item 2 Other-than-serious$0$0Jun 1, 2016Final

Inspection 341184588 OPENED JAN 15, 2016Closed

Planned · Complete · Safety · 220 employees at the site · Closed Sep 9, 2016

500 Waterway Drive, Amory, MS 38821 · Boat Building · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(e)(2)(iv)(a) · Flammable liquids
Serious$6,300$4,380Jun 1, 2016Final
Citation 1, item 2
29 CFR 1910.106(e)(3)(v)(a) · Flammable liquids
Serious$6,300$4,380Jun 1, 2016Final
Citation 1, item 3
29 CFR 1910.107(b)(3) · Spray painting and finishing
Serious$6,300$4,380Jun 1, 2016Final
Citation 1, item 4
29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing
Serious$3,825$2,600Jun 1, 2016Final
Citation 1, item 5
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$6,300$4,380Jun 1, 2016Final
Citation 1, item 6
29 CFR 1910.107(c)(9)(i) · Spray painting and finishing
Serious$6,300$4,380Jun 1, 2016Final
Citation 1, item 7
29 CFR 1910.107(g)(2) · Spray painting and finishing
Serious$6,300$4,380Jun 1, 2016Final
Citation 1, item 8
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$3,060$2,080Jun 1, 2016Final
Citation 1, item 9
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$2,295$1,660Jun 1, 2016Final
Citation 1, item 10
29 CFR 1910.305(a)(2)(ix) · Electrical wiring methods
Serious$3,060$2,090Jun 1, 2016Final
Citation 1, item 11
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$3,060$2,090Jun 1, 2016Final
Citation 1, item 12a
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Serious$2,295$1,660Jun 1, 2016Final
Citation 1, item 12b
29 CFR 1910.305(g)(1)(iv)(b) · Electrical wiring methods
Serious$0$0Jun 1, 2016Final
Citation 1, item 13
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$4,590$3,220Jun 1, 2016Final
Citation 2, item 1
29 CFR 1910.159(c)(10) · Automatic sprinkler systems
Other-than-serious$0$0Jun 1, 2016Final
Citation 2, item 2
29 CFR 1910.178(a)(4) · Forklifts and other powered industrial trucks
Other-than-serious$765$100Jun 1, 2016Final
Citation 2, item 3
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Other-than-serious$0$0Jun 1, 2016Final
Citation 2, item 4
29 CFR 1910.304(b)(3)(ii)(c)(3) · Grounding and circuit protection
Other-than-serious$0$0Jun 1, 2016Final
Citation 2, item 5
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Jun 1, 2016Final
Citation 2, item 6
29 CFR 1910.1200(f)(6) · Hazard communication
Other-than-serious$765$100Jun 1, 2016Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Nov 30, 2015, Amory: Hospitalization · fractures · cheek(s)

An employee was attempting to lift a part when the chain/hoist slipped off the part and the chain struck the employee in the face fracturing facial bones on the left side just below the eye.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(2)(iv)(a)

(iv) Handling liquids at point of final use. (a) Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be kept in covered containers when not actually in use.

29 CFR 1910.106(e)(3)(v)(a)

(v) Ventilation—(a) Areas as defined in paragraph (e)(3)(i) of this section using Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be ventilated at a rate of not less than 1 cubic foot per minute per square foot of solid floor area. This shall be accomplished by natural or mechanical ventilation with discharge or exhaust to a safe location outside of the building. Provision shall be made for introduction of makeup air in such a manner as not to short circuit the ventilation. Ventilation shall be arranged to include all floor areas or pits where flammable vapors may collect.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(3)

(3) Floors. The floor surface of a spray booth and operator's working area, if combustible, shall be covered with noncombustible material of such character as to facilitate the safe cleaning and removal of residues.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.141 · Sanitation

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.159 · Automatic sprinkler systems

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.95 · Noise

Other boat building employers in Mississippi

Alert subscribers get notified of each newly cited employer in Mississippi the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.