OSHA SearchOSHA records by employer

Norco, Inc.: OSHA inspections and violations

Boise, Idaho · Welding and Soldering Equipment Manufacturing · NAICS 333992

4inspections
6citation items
$50,010current penalties
Aug 15, 2019last inspection

Since 1974, OSHA inspectors have visited Norco, Inc. in Idaho 4 times.

The most recent inspection opened on Aug 15, 2019 on a referral, in Boise.

In all, OSHA issued 6 citation items: 3 serious, 1 repeat and 2 other-than-serious.

The proposed penalties came to $84,690; today they stand at $50,010, 41% less.

The rule cited most here is Section 5(a)(1) (the General Duty Clause), 2 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Norco, Inc. averages $24,990 across 2 cited inspections.

Norco, Inc. also files yearly injury logs with OSHA, summarized below.

It reported 2 severe injuries to OSHA since 2015.

Norco, Inc.: OSHA citation items per year, 1974 to 2019
Citation items per year, by inspection date.

Want to know if OSHA cites Norco, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 344244256 OPENED AUG 15, 2019Closed

Referral · Partial · Safety · 55 employees at the site · Closed Nov 12, 2019

850 West Gowen Rd., Boise, ID 83705 · Industrial Gas Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Aug 16, 2019: Employee is burned while blowing down acetylene cylinder

At approximately 5:15 a.m. on August 16, 2019, an employee was blowing down acetylene cylinders. Then, the acetylene gas ignited and caused burns to the employee on their arms and legs. The employee was hospitalized for these injuries.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Serious$13,260$6,630Oct 8, 2019Final
Citation 1, item 1b
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Serious$0$0Oct 8, 2019Final
Citation 2, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Repeat$66,300$39,780Oct 8, 2019Final

Inspection 340791375 OPENED JUL 22, 2015Closed

Referral · Partial · Safety · 3 employees at the site · Closed Oct 21, 2015

850 West Gowen Road, Boise, ID 83705 · Welding and Soldering Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$5,100$3,570Oct 2, 2015Final

Inspection 218319689 OPENED APR 2, 1974Closed

Follow-up · Complete · Safety · 23 employees at the site · Closed Mar 10, 1984

1522 River Street, Boise, ID 83707 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 218319226 OPENED JAN 15, 1974Closed

Planned · Complete · Safety · 23 employees at the site · Closed Mar 10, 1984

1522 River Street, Boise, ID 83707 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(e)(1) · Forklifts and other powered industrial trucks
Other-than-serious$30$30Jan 30, 1974Closed
Citation 1, item 2
29 CFR 1910.157(d)(3)(iv) · Portable fire extinguishers
Other-than-serious$0$0Jan 30, 1974Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Boise site logged 1 recordable injury or illness among about 123 workers: 0.8 per 100 full-time workers, against a median of 1.4 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Boise Main Office
Boise · 2025
123 100.81.4
Boise Fill Plant
Boise · 2025
83 414.70.7
Boise Industrial
Boise · 2025
16 000.01.4
Boise Medical
Boise · 2025
6 000.02.4
Boise Main Office
Boise · 2022
128 100.81.4
Main Office
Boise · 2021
128 201.51.4
Boise-Fuel and Fill Gas Plant
Boise · 2021
70 618.10.7
Fuel and Fill Gas Plant
Boise · 2019
61 416.90.7

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.

Aug 15, 2019, Boise: Hospitalization · heat (thermal) burns, unspecified · upper and lower limb(s)

An employee was blowing down acetylene bottles. The acetylene ignited and the employee's arms and legs were burned.

Jul 21, 2015, Boise: Hospitalization · heat (thermal) burns, unspecified · shoulder(s) and arm(s)

A flash fire at the acetylene filling plant burned an employee's arm and shoulder, resulting in hospitalization.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.132(a)

(a) Application. Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, shall be provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact.

29 CFR 1910.132(d)(1)

(d) Hazard assessment and equipment selection. (1) The employer shall assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE). If such hazards are present, or likely to be present, the employer shall:

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(d)(3)(iv)

(3) The employer may use uniformly spaced standpipe systems or hose stations connected to a sprinkler system installed for emergency use by employees instead of Class A portable fire extinguishers, provided that such systems meet the respective requirements of § 1910.158 or § 1910.159, that they provide total coverage of the area to be protected, and that employees are trained at least annually in their use.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

OSH Act Section 5 · General Duty Clause

Other welding and soldering equipment manufacturing employers in Idaho

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.