OSHA SearchOSHA records by employer

Nordic Fiberglass Inc: OSHA inspections and violations

Warren, Minnesota · All Other Miscellaneous Electrical Equipment and Component Manufacturing · NAICS 335999

10inspections
50citation items
$8,683current penalties
May 19, 2020last inspection

OSHA has inspected Nordic Fiberglass Inc 10 times in Minnesota since 1989.

The latest one began on May 19, 2020 after a complaint, in Warren.

Those inspections ended with 50 citation items: 22 serious, 2 repeat and 26 other-than-serious.

Penalties were first proposed at $13,158 and now stand at $8,683, 34% lower after settlements or reviews.

Air contaminants comes up most often in these citations: 6 items under 1910.1000.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Nordic Fiberglass Inc averages $1,620 (2 cited inspections).

Nordic Fiberglass Inc also files yearly injury logs with OSHA, summarized below.

Nordic Fiberglass Inc: OSHA citation items per year, 1989 to 2020
Citation items per year, by inspection date.

Minnesota · latest 90 days of OSHA records

370employers cited

Get notified the morning OSHA posts each new citation in Minnesota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Minnesota

Checking a subcontractor, a client or your own company? Watch Nordic Fiberglass Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344759378 OPENED MAY 19, 2020Closed

Complaint · Partial · Health · 50 employees at the site · Closed Dec 21, 2020

21415 Us Hwy 75 Nw, Warren, MN 56762 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.1000(a)(3) · Air contaminants
Repeat$3,000$2,100Jul 9, 2020Final
Citation 1, item 1b
29 CFR 1910.1000(e) · Air contaminants
Repeat$0$0Jul 9, 2020Final
Citation 1, item 2
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$600$420Jul 9, 2020Final

Inspection 343179024 OPENED MAY 22, 2018Closed

Planned · Complete · Health · 50 employees at the site · Closed Apr 30, 2019

21415 Us Hwy 75 Nw, Warren, MN 56762 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.1000(a)(3) · Air contaminants
Serious$600$360Aug 9, 2018Final
Citation 1, item 1b
29 CFR 1910.1000(e) · Air contaminants
Serious$0$0Aug 9, 2018Final
Citation 1, item 2 Serious$600$360Aug 9, 2018Final

Inspection 312950884 OPENED JAN 29, 2009Closed

Planned · Complete · Safety · 50 employees at the site · Closed Mar 31, 2009

21415 Us Hwy 75 Nw, Warren, MN 56762 · All Other Miscellaneous Electrical Equipment and Component Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.101(b) · Compressed gases (general requirements)
Serious$300$210Mar 3, 2009Closed
Citation 1, item 2
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$300$210Mar 3, 2009Closed
Citation 1, item 3
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$300$210Mar 3, 2009Closed
Citation 1, item 4
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$400$280Mar 3, 2009Closed
Citation 1, item 5
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$400$280Mar 3, 2009Closed
Citation 1, item 6
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$400$280Mar 3, 2009Closed
Citation 1, item 7
29 CFR 1910.305(d)(2) · Electrical wiring methods
Serious$400$280Mar 3, 2009Closed
Citation 1, item 8
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Serious$500$350Mar 3, 2009Closed
Citation 1, item 9 Serious$400$280Mar 3, 2009Closed
Citation 2, item 1
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$200$140Mar 3, 2009Closed

Inspection 307135806 OPENED DEC 4, 2003Closed

Planned · Complete · Safety · 66 employees at the site · Closed Feb 3, 2004

21415 Us Hwy 75 Nw, Warren, MN 56762 · All Other Miscellaneous Electrical Equipment and Component Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$450$315Jan 9, 2004Closed
Citation 2, item 1
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Other-than-serious$0$0Jan 9, 2004Closed
Citation 2, item 2a Other-than-serious$300$210Jan 9, 2004Closed
Citation 2, item 2b Other-than-serious$0$0Jan 9, 2004Closed

Inspection 303883482 OPENED NOV 2, 2000Closed

Planned · Complete · Safety · 50 employees at the site · Closed Jan 17, 2001

Hwy. 75 S, Warren, MN 56762 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(b)(2) · Electrical wiring methods
Serious$450$315Dec 6, 2000Closed
Citation 1, item 2
29 CFR 1910.305(d) · Electrical wiring methods
Serious$750$525Dec 6, 2000Closed

Inspection 126590710 OPENED APR 8, 1996Closed

Planned · Complete · Health · 50 employees at the site · Closed Jul 23, 1996

Hwy. 75 S, Warren, MN 56762 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(e)(9)(iii) · Flammable liquids
Serious$600$420May 28, 1996Closed
Citation 1, item 2
29 CFR 1910.119(e)(1) · Process safety management
Serious$900$100May 28, 1996Closed
Citation 1, item 4a
29 CFR 1910.1000(a)(2) · Air contaminants
Serious$600$420May 28, 1996Closed
Citation 1, item 4b
29 CFR 1910.1000(e) · Air contaminants
Serious$0$0May 28, 1996Closed
Citation 2, item 1 Other-than-serious$300$210May 28, 1996Closed

Inspection 111635629 OPENED JUL 2, 1991Closed

Follow-up · Partial · Safety · 23 employees at the site · Closed Jul 12, 1991

Hwy. 75 S, Warren, MN 56762 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 111635157 OPENED FEB 21, 1991Closed

Planned · Complete · Safety · 24 employees at the site · Closed May 10, 1991

Hwy. 75 S, Warren, MN 56762 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.151(c) · First aid and eyewash
Serious$150$150Mar 27, 1991Closed
Citation 1, item 2
29 CFR 1910.304(f)(5)(v) · Grounding and circuit protection
Serious$114$114Mar 27, 1991Closed
Citation 2, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Other-than-serious$0$0Mar 27, 1991Closed
Citation 2, item 2
29 CFR 1910.25(d)(2)(i) · Portable wood ladders
Other-than-serious$0$0Mar 27, 1991Closed
Citation 2, item 3
29 CFR 1910.27(d)(3) · Fixed ladders
Other-than-serious$0$0Mar 27, 1991Closed
Citation 2, item 4
29 CFR 1910.106(d)(2)(i) · Flammable liquids
Other-than-serious$72$72Mar 27, 1991Closed
Citation 2, item 5
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Other-than-serious$0$0Mar 27, 1991Closed
Citation 2, item 6
29 CFR 1910.107(b)(9) · Spray painting and finishing
Other-than-serious$0$0Mar 27, 1991Closed
Citation 2, item 7
29 CFR 1910.107(c)(7) · Spray painting and finishing
Other-than-serious$72$72Mar 27, 1991Closed
Citation 2, item 8
29 CFR 1910.107(e)(9) · Spray painting and finishing
Other-than-serious$0$0Mar 27, 1991Closed
Citation 2, item 9
29 CFR 1910.107(g)(2) · Spray painting and finishing
Other-than-serious$0$0Mar 27, 1991Closed
Citation 2, item 10
29 CFR 1910.147(c)(1) · Lockout/tagout
Other-than-serious$0$0Mar 27, 1991Closed
Citation 2, item 11
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0Mar 27, 1991Closed
Citation 2, item 12
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Mar 27, 1991Closed
Citation 2, item 13
29 CFR 1910.212(b) · Machine guarding
Other-than-serious$0$0Mar 27, 1991Closed
Citation 2, item 14
29 CFR 1910.213(b)(3) · Woodworking machinery
Other-than-serious$0$0Mar 27, 1991Closed
Citation 2, item 15
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Mar 27, 1991Closed
Citation 2, item 16
29 CFR 1910.303(f) · Electrical equipment, general requirements
Other-than-serious$0$0Mar 27, 1991Closed
Citation 2, item 17
29 CFR 1910.141(g)(3) · Sanitation
Other-than-serious$0$0Mar 27, 1991Closed
2 older inspections

Inspection 111683413 OPENED FEB 21, 1991Closed

Complaint · Partial · Health · 24 employees at the site · Closed Aug 13, 1991

Hwy. 75 S, Warren, MN 56762 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0Apr 23, 1991Closed
Citation 1, item 2
29 CFR 1910.134(a)(2) · Respiratory protection
Other-than-serious$0$0Apr 23, 1991Closed

Inspection 107739179 OPENED DEC 15, 1989Closed

Planned · Complete · Safety · 27 employees at the site · Closed Jan 26, 1990

Hwy. 75 S, Warren, MN 56762 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0Jan 23, 1990Closed
Citation 1, item 2
29 CFR 1910.304(f)(5)(vc) · Grounding and circuit protection
Other-than-serious$0$0Jan 23, 1990Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2024, the Warren site logged 5 recordable injuries or illnesses among about 56 workers: 9.9 per 100 full-time workers, against a median of 1.5 for its industry. Those cases cost 16 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Nordic Fiberglass, Inc-Warren
Warren · 2024
56 519.91.5
Nordic Fiberglass, Inc. - Warren, MN
Warren · 2023
63 417.01.5
Nordic Fiberglass Inc. Warren MN
Warren · 2022
68 10415.61.5

Included with any plan: 6 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1000 · Air contaminants

29 CFR 1910.1000(a)(2)

(2) Other substances—8-hour Time Weighted Averages. An employee's exposure to any substance in Table Z-1, the exposure limit of which is not preceded by a “C”, shall not exceed the 8-hour Time Weighted Average given for that substance in any 8-hour work shift of a 40-hour work week.

29 CFR 1910.1000(e)

(e) To achieve compliance with paragraphs (a) through (d) of this section, administrative or engineering controls must first be determined and implemented whenever feasible. When such controls are not feasible to achieve full compliance, protective equipment or any other protective measures shall be used to keep the exposure of employees to air contaminants within the limits prescribed in this section. Any equipment and/or technical measures used for this purpose must be approved for each particular use by a competent industrial hygienist or other technically qualified person. Whenever respirators are used, their use shall comply with 1910.134.

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.101(b)

(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.119 · Process safety management

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.141 · Sanitation

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.25 · Portable wood ladders

29 CFR 1910.27 · Fixed ladders

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.95 · Noise

29 CFR 5205.116

29 CFR 5205.1200

29 CFR 5205.675

Other all other miscellaneous electrical equipment and component manufacturing employers in Minnesota

Alert subscribers get notified of each newly cited employer in Minnesota the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.