OSHA SearchOSHA records by employer

Northwest Auto Body, Inc.: OSHA inspections and violations

Fargo, North Dakota · Automotive Body, Paint, and Interior Repair and Maintenance · NAICS 811121

6inspections
21citation items
$2,783current penalties
Jan 16, 2019last inspection

OSHA has inspected Northwest Auto Body, Inc. 6 times in North Dakota since 1976.

The latest one began on Jan 16, 2019 as a planned inspection, in Fargo.

Those inspections ended with 21 citation items: 1 serious, 1 repeat and 19 other-than-serious.

Penalties were first proposed at $4,469 and now stand at $2,783, 38% lower after settlements or reviews.

Spray painting and finishing comes up most often in these citations: 6 items under 1910.107.

How that compares: the median penalty per cited inspection for repair and personal services employers since 2015 is $1,200, and Northwest Auto Body, Inc. averages $1,264 (2 cited inspections).

Northwest Auto Body, Inc.: OSHA citation items per year, 1976 to 2019
Citation items per year, by inspection date.

North Dakota · latest 90 days of OSHA records

29employers cited

Get notified the morning OSHA posts each new citation in North Dakota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Dakota

Checking a subcontractor, a client or your own company? Watch Northwest Auto Body, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343717666 OPENED JAN 16, 2019Closed

Planned · Complete · Health · 19 employees at the site · Closed Jan 30, 2020

1534 Main Avenue, Fargo, ND 58103 · Automotive Body, Paint, and Interior Repair and Maintenance · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$3,789$2,273Jun 19, 2019Final

Inspection 343734067 OPENED JAN 16, 2019Closed

Planned · Complete · Safety · 19 employees at the site · Closed Dec 16, 2022

1534 Main Avenue, Fargo, ND 58103 · Automotive Body, Paint, and Interior Repair and Maintenance · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Other-than-serious$425$255Mar 29, 2019Final
Citation 1, item 1b
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Mar 29, 2019Final

Inspection 313043127 OPENED APR 15, 2009Closed

Planned · No inspection · Safety · Closed May 12, 2009

1522 Main Avenue, Fargo, ND 58103 · Automotive Body, Paint, and Interior Repair and Maintenance · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 217806116 OPENED JAN 5, 1978Closed

Follow-up · Complete · Safety · 9 employees at the site · Closed Mar 10, 1984

1522 Main, Fargo, ND 58102 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 217812429 OPENED JAN 17, 1977Closed

Complaint · Complete · Safety · 9 employees at the site · Closed Jan 10, 1978

1522 Main, Fargo, ND 58102 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 3, item 1
29 CFR 1910.22(a)(1) · General requirements
Repeat$90$90Jan 25, 1977Closed
Citation 4, item 1
29 CFR 1910.106(d)(4)(iv) · Flammable liquids
Other-than-serious$0$0Jan 25, 1977Closed
Citation 4, item 2
29 CFR 1910.106(e)(2)(ivd) · Flammable liquids
Other-than-serious$0$0Feb 18, 1977Closed
Citation 4, item 3
29 CFR 1910.107(d)(2) · Spray painting and finishing
Other-than-serious$0$0Feb 18, 1977Closed
Citation 4, item 4
29 CFR 1910.107(e)(2) · Spray painting and finishing
Other-than-serious$0$0Jan 25, 1977Closed
Citation 4, item 5
29 CFR 1910.107(e)(4) · Spray painting and finishing
Other-than-serious$30$30Jan 25, 1977Closed
Citation 4, item 6
29 CFR 1910.107(e)(9) · Spray painting and finishing
Other-than-serious$0$0Jan 25, 1977Closed
Citation 4, item 7
29 CFR 1910.134(b)(1) · Respiratory protection
Other-than-serious$50$50Jan 25, 1977Closed
Citation 4, item 8
29 CFR 1910.134(b)(4) · Respiratory protection
Other-than-serious$0$0Jan 25, 1977Closed
Citation 4, item 9
29 CFR 1910.134(b)(6) · Respiratory protection
Other-than-serious$0$0Jan 25, 1977Closed
Citation 4, item 10
29 CFR 1910.107(c)(6) · Spray painting and finishing
Other-than-serious$50$50Feb 18, 1977Closed

Inspection 217804251 OPENED JAN 29, 1976Closed

Planned · Complete · Safety · 6 employees at the site · Closed Mar 10, 1976

1522 Main Avenue, Fargo, ND 58102 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 2, item 1
29 CFR 1910.157(d)(3)(i) · Portable fire extinguishers
Other-than-serious$0$0Feb 4, 1976Closed
Citation 2, item 2
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Other-than-serious$0$0Feb 4, 1976Closed
Citation 2, item 3
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Feb 4, 1976Closed
Citation 2, item 4
29 CFR 1910.157(a)(5) · Portable fire extinguishers
Other-than-serious$0$0Feb 4, 1976Closed
Citation 2, item 5 Other-than-serious$0$0Feb 4, 1976Closed
Citation 2, item 6
29 CFR 1910.107(a)(6) · Spray painting and finishing
Other-than-serious$35$35Feb 4, 1976Closed
Citation 2, item 7
29 CFR 1910.22(a)(1) · General requirements
Other-than-serious$0$0Feb 4, 1976Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(iv)

(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.

29 CFR 1910.106(e)(2)(ivd)

(iv) Handling liquids at point of final use. (a) Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be kept in covered containers when not actually in use.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(a)(6)

(6) Fluidized bed. A container holding powder coating material which is aerated from below so as to form an air-supported expanded cloud of such material through which the preheated object to be coated is immersed and transported.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.22 · General requirements

29 CFR 1910.309

Other automotive body, paint, and interior repair and maintenance employers in North Dakota

Alert subscribers get notified of each newly cited employer in North Dakota the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.