Inspection 341677318 OPENED AUG 8, 2016Closed
3980 Jennings Rd, Cleveland, OH 44109 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 2016, OSHA inspectors have visited Northwest Services, Inc. in Ohio 2 times.
The most recent inspection opened on Aug 8, 2016 on a referral, in Cleveland.
In all, OSHA issued 12 citation items: 7 serious and 5 other-than-serious.
The proposed penalties came to $15,677; today they stand at $6,414, 59% less.
The rule cited most here is 1910.134 (respiratory protection), 4 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Northwest Services, Inc. averages $6,414 across 1 cited inspection.
Ohio · latest 90 days of OSHA records
267employers cited
3 of them in the same industry
Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Ohio
Checking a subcontractor, a client or your own company? Watch Northwest Services, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company3980 Jennings Rd, Cleveland, OH 44109 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
3980 Jennings Rd, Cleveland, OH 44109 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.95(g)(1) · Noise |
Serious | $3,563 | $2,138 | Nov 30, 2016 | Final |
| Citation 1, item 2a 29 CFR 1910.107(c)(5) · Spray painting and finishing |
Serious | $2,850 | $1,710 | Nov 30, 2016 | Final |
| Citation 1, item 2b 29 CFR 1910.107(g)(2) · Spray painting and finishing |
Serious | $2,850 | $0 | Nov 30, 2016 | Final |
| Citation 1, item 4a 29 CFR 1910.134(c)(1)(vi) · Respiratory protection |
Serious | $2,138 | $1,283 | Nov 30, 2016 | Final |
| Citation 1, item 4b 29 CFR 1910.134(i)(1)(ii) · Respiratory protection |
Serious | $0 | $0 | Nov 30, 2016 | Final |
| Citation 1, item 4c 29 CFR 1910.134(i)(7) · Respiratory protection |
Serious | $0 | $0 | Nov 30, 2016 | Final |
| Citation 1, item 5a 29 CFR 1910.157(e)(2) · Portable fire extinguishers |
Other-than-serious | $2,138 | $0 | Nov 30, 2016 | Final |
| Citation 1, item 5b 29 CFR 1910.157(e)(3) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Nov 30, 2016 | Final |
| Citation 1, item 6 29 CFR 1910.252(b)(2)(iii) · Welding fire safety |
Serious | $2,138 | $1,283 | Nov 30, 2016 | Final |
| Citation 2, item 1 29 CFR 1910.107(b)(5)(i) · Spray painting and finishing |
Other-than-serious | $0 | $0 | Nov 30, 2016 | Final |
| Citation 2, item 2 29 CFR 1910.107(g)(7) · Spray painting and finishing |
Other-than-serious | $0 | $0 | Nov 30, 2016 | Final |
| Citation 2, item 3 29 CFR 1910.134(f)(1) · Respiratory protection |
Other-than-serious | $0 | $0 | Nov 30, 2016 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.107(b)(5)(i)
(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.
29 CFR 1910.107(c)(5)
(5) Combustible residues, areas. Unless specifically approved for locations containing both deposits of readily ignitable residue and explosive vapors, there shall be no electrical equipment in any spraying area, whereon deposits of combustible residues may readily accumulate, except wiring in rigid conduit or in boxes or fittings containing no taps, splices, or terminal connections.
29 CFR 1910.107(g)(2)
(2) Cleaning. All spraying areas shall be kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary. Scrapers, spuds, or other such tools used for cleaning purposes shall be of nonsparking material.
Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.