OSHA SearchOSHA records by employer

Oak Creations, Inc.: OSHA inspections and violations

Columbus, Montana · Wood Kitchen Cabinet and Countertop Manufacturing · NAICS 337110

2inspections
34citation items
$40,000current penalties
Feb 18, 2015last inspection

OSHA has inspected Oak Creations, Inc. 2 times in Montana since 2015.

The latest one began on Feb 18, 2015 on a referral, in Columbus.

Those inspections ended with 34 citation items: 32 serious and 2 other-than-serious.

Penalties were first proposed at $44,400 and now stand at $40,000, 10% lower after settlements or reviews.

Woodworking machinery comes up most often in these citations: 9 items under 1910.213.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Oak Creations, Inc. averages $20,000 (2 cited inspections).

1 inspection on this page followed a fatal incident.

Oak Creations, Inc.: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Montana · latest 90 days of OSHA records

24employers cited

Get notified the morning OSHA posts each new citation in Montana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Montana

Checking a subcontractor, a client or your own company? Watch Oak Creations, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340416684 OPENED FEB 18, 2015Closed

Referral · Partial · Health · 4 employees at the site · Closed Nov 6, 2015

1035 Hwy 10, Columbus, MT 59019 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(d)(1)(iii) · Respiratory protection
Serious$1,200$1,200Jul 20, 2015Final
Citation 1, item 2
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$1,200$1,200Jul 20, 2015Final
Citation 2, item 1
29 CFR 1910.134(k)(6) · Respiratory protection
Other-than-serious$0$0Jul 20, 2015Final

Inspection 340194265 OPENED JAN 22, 2015Closed

Fatality or catastrophe · Complete · Safety · 5 employees at the site · Closed Sep 14, 2018

1035 Hwy 10, Columbus, MT 59019 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Jan 14, 2015 (fatal): Employee dies of respiratory illness after exposure to oak s

At approximately 8:15 p.m., an employee was killed after 15-year exposure to sawdust and silica. The exposure to sawdust and sandpaper came from making cabinets. The coroners report stated that the employee's lungs were filled with oak sawdust and silica from sandpaper.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$2,800$2,800Jul 20, 2015Final
Citation 1, item 2
29 CFR 1910.22(a)(1) · General requirements
Serious$2,800$2,800Jul 20, 2015Final
Citation 1, item 4a
29 CFR 1910.107(c)(3) · Spray painting and finishing
Serious$2,800$2,800Jul 20, 2015Final
Citation 1, item 4b
29 CFR 1910.107(c)(4) · Spray painting and finishing
Serious$0$0Jul 20, 2015Final
Citation 1, item 4c
29 CFR 1910.107(c)(5) · Spray painting and finishing
Serious$0$0Jul 20, 2015Final
Citation 1, item 4d
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$0$0Jul 20, 2015Final
Citation 1, item 4e
29 CFR 1910.107(d)(5) · Spray painting and finishing
Serious$0$0Jul 20, 2015Final
Citation 1, item 6
29 CFR 1910.107(g)(2) · Spray painting and finishing
Serious$2,800$2,800Jul 20, 2015Final
Citation 1, item 7a
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,600$800Jul 20, 2015Final
Citation 1, item 7b
29 CFR 1910.212(b) · Machine guarding
Serious$0$0Jul 20, 2015Final
Citation 1, item 8a
29 CFR 1910.213(a)(9) · Woodworking machinery
Serious$1,600$1,600Jul 20, 2015Final
Citation 1, item 8b
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$0$0Jul 20, 2015Final
Citation 1, item 8c
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Jul 20, 2015Final
Citation 1, item 9a
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$2,800$2,800Jul 20, 2015Final
Citation 1, item 9b
29 CFR 1910.213(c)(2) · Woodworking machinery
Serious$0$0Jul 20, 2015Final
Citation 1, item 9c
29 CFR 1910.213(c)(3) · Woodworking machinery
Serious$0$0Jul 20, 2015Final
Citation 1, item 10a
29 CFR 1910.213(h)(1) · Woodworking machinery
Serious$2,800$2,800Jul 20, 2015Final
Citation 1, item 10b
29 CFR 1910.213(h)(2) · Woodworking machinery
Serious$0$0Jul 20, 2015Final
Citation 1, item 10c
29 CFR 1910.213(h)(4) · Woodworking machinery
Serious$0$0Jul 20, 2015Final
Citation 1, item 11
29 CFR 1910.213(p)(2) · Woodworking machinery
Serious$1,600$1,600Jul 20, 2015Final
Citation 1, item 12
29 CFR 1910.213(s)(6) · Woodworking machinery
Serious$2,800$2,800Jul 20, 2015Final
Citation 1, item 13
29 CFR 1910.242(b) · Hand and power tools
Serious$1,600$1,000Jul 20, 2015Final
Citation 1, item 14
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$2,400$1,200Jul 20, 2015Final
Citation 1, item 15
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Serious$2,800$1,000Jul 20, 2015Final
Citation 1, item 16
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$2,400$2,400Jul 20, 2015Final
Citation 1, item 17a
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$2,800$2,800Jul 20, 2015Final
Citation 1, item 17b
29 CFR 1910.305(b)(2) · Electrical wiring methods
Serious$0$0Jul 20, 2015Final
Citation 1, item 18a
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Serious$2,800$2,800Jul 20, 2015Final
Citation 1, item 18b
29 CFR 1910.305(g)(1)(iv)(d) · Electrical wiring methods
Serious$0$0Jul 20, 2015Final
Citation 1, item 19
29 CFR 1910.307(c) · Hazardous (classified) locations
Serious$2,800$2,800Jul 20, 2015Final
Citation 2, item 1
29 CFR 1910.37(b)(2) · Exit routes
Other-than-serious$0$0Jul 20, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(c)(3)

(3) Hot surfaces. Space-heating appliances, steampipes, or hot surfaces shall not be located in a spraying area where deposits of combustible residues may readily accumulate.

29 CFR 1910.107(c)(4)

(4) Wiring conformance. Electrical wiring and equipment shall conform to the provisions of this paragraph and shall otherwise be in accordance with subpart S of this part.

29 CFR 1910.107(c)(5)

(5) Combustible residues, areas. Unless specifically approved for locations containing both deposits of readily ignitable residue and explosive vapors, there shall be no electrical equipment in any spraying area, whereon deposits of combustible residues may readily accumulate, except wiring in rigid conduit or in boxes or fittings containing no taps, splices, or terminal connections.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.307 · Hazardous (classified) locations

29 CFR 1910.37 · Exit routes

OSH Act Section 5 · General Duty Clause

Other wood kitchen cabinet and countertop manufacturing employers in Montana

Alert subscribers get notified of each newly cited employer in Montana the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.