OSHA SearchOSHA records by employer

Oklaunion Power Station: OSHA inspections and violations

Vernon, Texas · Electric Power Generation · NAICS 221119

1inspections
4citation items
$14,586current penalties
Aug 21, 2019last inspection

OSHA inspectors have visited Oklaunion Power Station in Texas one time.

It opened on Aug 21, 2019 on a referral, in Vernon.

In all, OSHA issued 4 citation items: 4 other-than-serious.

The proposed penalties came to $19,890; today they stand at $14,586, 27% less.

The rule cited most here is 1910.269 (electric power generation, transmission, and distribution), 4 times.

Among utility employers, the typical cited inspection since 2015 ends with a $0 penalty. Oklaunion Power Station averages $14,586 across 1 cited inspection.

It reported 1 severe injury to OSHA since 2015.

Oklaunion Power Station: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

399employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Oklaunion Power Station and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344250170 OPENED AUG 21, 2019Closed

Referral · Partial · Safety · 69 employees at the site · Closed Mar 26, 2020

12567 Fm 3430, Vernon, TX 76384 · Electric Power Generation · OSHA's record · Phone and website on Google Maps

Incident on Aug 6, 2019: Employee is burned in electrical arc flash

At 2:00 p.m. an employee was checking fuses inside an electrical panel box. The employee was struck by an arc flash. The employee was hospitalized to treat burns to the hands and face.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.269(a)(2)(iv) · Electric power generation, transmission, and distribution
Other-than-serious$5,304$9,282Sep 3, 2019Final
Citation 1, item 1b
29 CFR 1910.269(c)(5) · Electric power generation, transmission, and distribution
Other-than-serious$9,282$0Sep 3, 2019Final
Citation 1, item 4a
29 CFR 1910.269(a)(2)(v)(a) · Electric power generation, transmission, and distribution
Other-than-serious$5,304$5,304Sep 3, 2019Final
Citation 1, item 4b
29 CFR 1910.269(a)(2)(vii) · Electric power generation, transmission, and distribution
Other-than-serious$0$0Sep 3, 2019Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Aug 6, 2019, Vernon: Hospitalization · electrical burns, unspecified · multiple body parts, n.e.c.

An employee was checking fuses at a 480-volt control panel when a flash fire occurred burning the employees face, left hand, and right forearm.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.269 · Electric power generation, transmission, and distribution

29 CFR 1910.269(a)(2)(iv)

(iv) The employer shall determine, through regular supervision and through inspections conducted on at least an annual basis, that each employee is complying with the safety-related work practices required by this section.

29 CFR 1910.269(a)(2)(v)(a)

(A) If the supervision or annual inspections required by paragraph (a)(2)(iv) of this section indicate that the employee is not complying with the safety-related work practices required by this section, or

29 CFR 1910.269(a)(2)(vii)

(vii) The training shall establish employee proficiency in the work practices required by this section and shall introduce the procedures necessary for compliance with this section.

Other electric power generation employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.