OSHA SearchOSHA records by employer

Olde World Masonry Inc: OSHA inspections and violations

Indianapolis, Indiana · Masonry Contractors · NAICS 238140

6inspections
19citation items
$8,912current penalties
Mar 20, 2015last inspection

Since 2007, OSHA inspectors have visited Olde World Masonry Inc in Indiana 6 times.

The most recent inspection opened on Mar 20, 2015 as part of a related case, in Indianapolis.

In all, OSHA issued 19 citation items: 19 serious.

The proposed penalties came to $16,600; today they stand at $8,912, 46% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 6 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Olde World Masonry Inc averages $2,850 across 1 cited inspection.

Olde World Masonry Inc: OSHA citation items per year, 2007 to 2015
Citation items per year, by inspection date.

Indiana · latest 90 days of OSHA records

84employers cited

Get notified the morning OSHA posts each new citation in Indiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Indiana

Checking a subcontractor, a client or your own company? Watch Olde World Masonry Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 317863728 OPENED MAR 20, 2015Closed

Unprogrammed related · Partial · Safety · 1 employee at the site · Closed Dec 4, 2015

617 North College Avenue, Indianapolis, IN 46204 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$450$450Jul 7, 2015Closed
Citation 1, item 2
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$600$600Jul 7, 2015Closed
Citation 1, item 3
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$600$600Jul 7, 2015Closed
Citation 1, item 4
29 CFR 1926.452(c)(5)(iii) · Rules for each type of scaffold
Serious$750$750Jul 7, 2015Closed
Citation 1, item 5a
29 CFR 1926.454(a) · Scaffold training
Serious$450$450Jul 7, 2015Closed
Citation 1, item 6b
29 CFR 1926.454(b) · Scaffold training
Serious$0$0Jul 7, 2015Closed

Inspection 315050237 OPENED AUG 1, 2011Closed

Unprogrammed other · Partial · Safety · 8 employees at the site · Closed Oct 5, 2011

701 North College Ave., Bloomington, IN 47407 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$500$325Sep 16, 2011Closed
Citation 1, item 2a
29 CFR 1926.21(b)(2) · Construction safety training
Serious$500$325Sep 16, 2011Closed
Citation 1, item 2b
29 CFR 1910.178(l)(4)(i) · Forklifts and other powered industrial trucks
Serious$0$0Sep 16, 2011Closed
Citation 1, item 2c
29 CFR 1926.454(c)(3) · Scaffold training
Serious$0$0Sep 16, 2011Closed
Citation 1, item 3
29 CFR 1926.451(c)(2)(iv) · Scaffolds, general requirements
Serious$500$325Sep 16, 2011Closed

Inspection 315048587 OPENED JUL 27, 2011Closed

Planned · Complete · Safety · 8 employees at the site · Closed Aug 10, 2011

860 W. 10th Street, Indianapolis, IN 46204 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 314271610 OPENED MAY 28, 2010Closed

Complaint · Partial · Safety · 1 employee at the site · Closed Aug 18, 2010

10th & Morton Street, Bloomington, IN 47401 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$375$244Jul 16, 2010Closed
Citation 1, item 2
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$375$244Jul 16, 2010Closed

Inspection 312653181 OPENED APR 20, 2009Closed

Complaint · Partial · Safety · 12 employees at the site · Closed Sep 17, 2009

602 N. Morton Street, Bloomington, IN 47404 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$750$450Jun 30, 2009Closed
Citation 1, item 2
29 CFR 1926.451(c)(1) · Scaffolds, general requirements
Serious$2,500$925Jun 30, 2009Closed
Citation 1, item 3
29 CFR 1926.452(c)(5)(iii) · Rules for each type of scaffold
Serious$2,500$925Jun 30, 2009Closed
Citation 1, item 4
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$2,500$925Jun 30, 2009Closed
Citation 1, item 5
29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements
Serious$750$450Jun 30, 2009Closed
Citation 1, item 6
29 CFR 1926.452(c)(4) · Rules for each type of scaffold
Serious$2,500$925Jun 30, 2009Closed

Inspection 310369459 OPENED JAN 9, 2007Closed

Planned · Partial · Safety · 6 employees at the site · Closed Feb 7, 2007

5702 West Washington Street, Indianapolis, IN 46219 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.1200(h)(1)

(h) Employee information and training. (1) Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.21 · Construction safety training

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

Other masonry contractors employers in Indiana

Alert subscribers get notified of each newly cited employer in Indiana the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.