OSHA SearchOSHA records by employer

Orleans Casket Company, Inc.: OSHA inspections and violations

Mandeville, Louisiana · All Other Miscellaneous Wood Product Manufacturing · NAICS 321999

7inspections
43citation items
$16,675current penalties
Nov 21, 2023last inspection

OSHA has inspected Orleans Casket Company, Inc. 7 times in Louisiana since 1984.

The latest one began on Nov 21, 2023 after a complaint, in Mandeville.

Those inspections ended with 43 citation items: 23 serious and 20 other-than-serious.

Penalties were first proposed at $34,072 and now stand at $16,675, 51% lower after settlements or reviews.

Woodworking machinery comes up most often in these citations: 6 items under 1910.213.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Orleans Casket Company, Inc. averages $6,053 (2 cited inspections).

Orleans Casket Company, Inc.: OSHA citation items per year, 1984 to 2023
Citation items per year, by inspection date.

Louisiana · latest 90 days of OSHA records

18employers cited

Get notified the morning OSHA posts each new citation in Louisiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Louisiana

Checking a subcontractor, a client or your own company? Watch Orleans Casket Company, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347117962 OPENED NOV 21, 2023Closed

Complaint · Partial · Safety · 5 employees at the site · Closed Dec 13, 2023

1760 South Lane, Mandeville, LA 70471 · All Other Miscellaneous Wood Product Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343909719 OPENED APR 1, 2019Closed

Follow-up · Partial · Safety · 17 employees at the site · Closed Jul 2, 2019

1760 South Lane, Mandeville, LA 70471 · All Other Miscellaneous Wood Product Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342027562 OPENED JAN 10, 2017Closed

Complaint · Partial · Health · 14 employees at the site · Closed Mar 9, 2017

1760 South Lane, Mandeville, LA 70471 · All Other Miscellaneous Wood Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$2,173$1,304Feb 17, 2017Final
Citation 1, item 2
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$2,173$1,304Feb 17, 2017Final
Citation 1, item 3
29 CFR 1910.134(f)(1) · Respiratory protection
Serious$2,173$1,304Feb 17, 2017Final

Inspection 341823722 OPENED OCT 6, 2016Closed

Complaint · Partial · Safety · 12 employees at the site · Closed Jul 25, 2017

1760 South Lane, Mandeville, LA 70471 · All Other Miscellaneous Wood Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$2,138$1,069Jan 9, 2017Final
Citation 1, item 2
29 CFR 1910.213(d)(1) · Woodworking machinery
Serious$3,563$1,782Jan 9, 2017Final
Citation 1, item 3a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$4,988$2,494Jan 9, 2017Final
Citation 1, item 3b
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Jan 9, 2017Final
Citation 1, item 3c
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$0$0Jan 9, 2017Final
Citation 1, item 4 Other-than-serious$3,563$0Jan 9, 2017Final
Citation 1, item 5
29 CFR 1910.303(b)(1) · Electrical equipment, general requirements
Serious$3,563$1,782Jan 9, 2017Final
Citation 1, item 6
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$2,138$1,069Jan 9, 2017Final

Inspection 110346335 OPENED MAY 3, 1994Closed

Planned · Complete · Safety · 32 employees at the site · Closed Sep 27, 1994

1750 S. Lane, Mandeville, LA 70445 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.151(b) · First aid and eyewash
Serious$750$503May 27, 1994Closed
Citation 1, item 2
29 CFR 1910.212(a)(5) · Machine guarding
Serious$750$503May 27, 1994Closed
Citation 1, item 3
29 CFR 1910.213(i)(1) · Woodworking machinery
Serious$1,000$500May 27, 1994Closed
Citation 1, item 4
29 CFR 1910.217(b)(4)(i) · Mechanical power presses
Serious$1,250$625May 27, 1994Closed
Citation 1, item 5
29 CFR 1910.217(c)(1)(i) · Mechanical power presses
Serious$1,250$625May 27, 1994Closed
Citation 1, item 6
29 CFR 1910.303(b)(1) · Electrical equipment, general requirements
Serious$1,250$838May 27, 1994Closed
Citation 1, item 7
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$750$375May 27, 1994Closed
Citation 2, item 1
29 CFR 1910.107(b)(9) · Spray painting and finishing
Other-than-serious$0$0May 27, 1994Closed
Citation 2, item 2
29 CFR 1910.134(a)(2) · Respiratory protection
Other-than-serious$0$0May 27, 1994Closed
Citation 2, item 3
29 CFR 1910.134(e)(5)(i) · Respiratory protection
Other-than-serious$0$0May 27, 1994Closed
Citation 2, item 4
29 CFR 1910.147(c)(1) · Lockout/tagout
Other-than-serious$0$0May 27, 1994Closed
Citation 2, item 5
29 CFR 1910.217(b)(4)(ii) · Mechanical power presses
Other-than-serious$0$0May 27, 1994Closed
Citation 2, item 6
29 CFR 1910.217(e)(1)(i) · Mechanical power presses
Other-than-serious$0$0May 27, 1994Closed
Citation 2, item 7
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0May 27, 1994Closed
Citation 2, item 8
29 CFR 1910.305(b)(2) · Electrical wiring methods
Other-than-serious$0$0May 27, 1994Closed
Citation 2, item 9
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0May 27, 1994Closed

Inspection 1924869 OPENED FEB 27, 1985Closed

Planned · Complete · Safety · 48 employees at the site · Closed Apr 12, 1985

Pine Grove Industrial Park Hwy 59, Mandeville, LA 70448 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$180$180Mar 12, 1985Closed
Citation 1, item 2
29 CFR 1910.213(h)(1) · Woodworking machinery
Serious$180$180Mar 12, 1985Closed
Citation 2, item 1
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Other-than-serious$0$0Mar 12, 1985Closed
Citation 2, item 2
29 CFR 1910.305(b)(2) · Electrical wiring methods
Other-than-serious$0$0Mar 12, 1985Closed

Inspection 1622471 OPENED SEP 17, 1984Closed

Planned · Complete · Health · 49 employees at the site · Closed Dec 4, 1984

Hwy 59 Pine Grove Industrial Park, Mandeville, LA 70448 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$160$160Sep 27, 1984Closed
Citation 1, item 1b
29 CFR 1910.213(c)(2) · Woodworking machinery
Serious$0$0Sep 27, 1984Closed
Citation 1, item 1c
29 CFR 1910.213(c)(3) · Woodworking machinery
Serious$0$0Sep 27, 1984Closed
Citation 1, item 2
29 CFR 1910.243(c)(3) · Guarding of portable powered tools
Serious$80$80Sep 27, 1984Closed
Citation 2, item 1
29 CFR 1903.2(a)(1) · Posting of notice; availability of the Act, regulations and applicable standards
Other-than-serious$0$0Sep 27, 1984Closed
Citation 2, item 2 Other-than-serious$0$0Sep 27, 1984Closed
Citation 2, item 3a
29 CFR 1910.106(f)(6) · Flammable liquids
Other-than-serious$0$0Sep 27, 1984Closed
Citation 2, item 3b
29 CFR 1910.107(g)(7) · Spray painting and finishing
Other-than-serious$0$0Sep 27, 1984Closed
Citation 2, item 4
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Other-than-serious$0$0Sep 27, 1984Closed
Citation 2, item 5
29 CFR 1910.107(e)(9) · Spray painting and finishing
Other-than-serious$0$0Sep 27, 1984Closed
Citation 2, item 6
29 CFR 1910.215(a)(2) · Grinders and abrasive wheels
Other-than-serious$0$0Sep 27, 1984Closed
Citation 2, item 7
29 CFR 1910.252(a)(2) · Welding fire safety
Other-than-serious$0$0Sep 27, 1984Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.2 · Posting of notice; availability of the Act, regulations and applicable standards

29 CFR 1903.2(a)(1)

(a)(1) Each employer shall post and keep posted a notice or notices, to be furnished by the Occupational Safety and Health Administration, U.S. Department of Labor, informing employees of the protections and obligations provided for in the Act, and that for assistance and information, including copies of the Act and of specific safety and health standards, employees should contact the employer or the nearest office of the Department of Labor. Such notice or notices shall be posted by the employer in each establishment in a conspicuous place or places where notices to employees are customarily posted. Each employer shall take steps to insure that such notices are not altered, defaced, or covered by other material.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(f)(6)

(6) Sources of ignition. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be handled, drawn, or dispensed where flammable vapors may reach a source of ignition. Smoking shall be prohibited except in designated localities. “No Smoking” signs shall be conspicuously posted where hazard from flammable liquid vapors is normally present.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.217 · Mechanical power presses

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.265 · Sawmills

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.95 · Noise

Other all other miscellaneous wood product manufacturing employers in Louisiana