OSHA SearchOSHA records by employer

Palmer Tool, LLC: OSHA inspections and violations

Camden, Tennessee · Power Boiler and Heat Exchanger Manufacturing · NAICS 332410

18inspections
84citation items
$20,364current penalties
Jan 20, 2023last inspection

Palmer Tool, LLC has 18 OSHA inspections on record in Tennessee, the first in 1984.

OSHA's last visit started on Jan 20, 2023 on a referral, in Camden.

Across those inspections OSHA issued 84 citation items: 43 serious, 2 repeat and 39 other-than-serious.

OSHA proposed $24,000 in penalties. After settlements and reviews the total is $20,364, down 15%.

Most often, OSHA cited 1910.134, respiratory protection (8 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Palmer Tool, LLC averages $1,950 over 3 cited inspections in that time.

Palmer Tool, LLC: OSHA citation items per year, 1984 to 2023
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

344employers cited

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch Palmer Tool, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346449184 OPENED JAN 20, 2023Closed

Referral · Partial · Safety · 49 employees at the site · Closed Apr 6, 2023

3385 Us Hwy 70 East, Camden, TN 38320 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$900$900Feb 27, 2023Final
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$900$900Feb 27, 2023Final
Citation 2, item 1
29 CFR 1910.147(c)(7)(iv) · Lockout/tagout
Other-than-serious$0$0Feb 27, 2023Final
Citation 2, item 2
29 CFR 1910.151(b) · First aid and eyewash
Other-than-serious$150$150Feb 27, 2023Final
Citation 2, item 3
29 CFR 1910.1030(g)(2)(ii)(b) · Bloodborne pathogens
Other-than-serious$0$0Feb 27, 2023Final

Inspection 346426273 OPENED JAN 10, 2023Closed

Planned · Partial · Health · 40 employees at the site · Closed Mar 4, 2024

3385 Highway 70 East, Camden, TN 38320 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.252(a)(2)(vii) · Welding fire safety
Other-than-serious$150$150Mar 20, 2023Final

Inspection 342695277 OPENED OCT 11, 2017Closed

Follow-up · Partial · Safety · 55 employees at the site · Closed Oct 19, 2017

3385 Highway 70 East, Camden, TN 38320 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342157765 OPENED MAR 8, 2017Closed

Planned · Complete · Safety · 48 employees at the site · Closed Jun 8, 2017

3385 Highway 70 East, Camden, TN 38320 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR TCA 50-3-105(1)
Serious$1,500$1,500Apr 19, 2017Final
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,500$1,500Apr 19, 2017Final
Citation 2, item 1
29 CFR 1910.242(b) · Hand and power tools
Repeat$300$300Apr 19, 2017Final
Citation 3, item 1
29 CFR 1910.157(g)(2) · Portable fire extinguishers
Other-than-serious$300$300Apr 19, 2017Final
Citation 3, item 2
29 CFR TDLWD RULE 800-01-09-.07(4)
Other-than-serious$150$150Apr 19, 2017Final

Inspection 317145993 OPENED APR 24, 2013Closed

Planned · Complete · Safety · 65 employees at the site · Closed Jun 14, 2013

3385 Highway 70e, Camden, TN 38320 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$750$750May 13, 2013Closed
Citation 1, item 1b Serious$0$0May 13, 2013Closed
Citation 2, item 1
29 CFR 1910.179(g)(1)(v) · Overhead and gantry cranes
Other-than-serious$0$0May 13, 2013Closed
Citation 2, item 2
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0May 13, 2013Closed
Citation 2, item 3
29 CFR 1910.242(b) · Hand and power tools
Other-than-serious$150$150May 13, 2013Closed
Citation 2, item 4
29 CFR 1910.1200(f)(6)(ii) · Hazard communication
Other-than-serious$0$0May 13, 2013Closed
Citation 2, item 5
29 CFR 9000602
Other-than-serious$0$0May 13, 2013Closed

Inspection 316389899 OPENED FEB 15, 2012Closed

Planned · Complete · Health · 65 employees at the site · Closed May 30, 2012

3385 Highway 70e, Camden, TN 38320 · Power Boiler and Heat Exchanger Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(h)(2)(i) · Respiratory protection
Serious$800$600May 1, 2012Closed
Citation 1, item 1b
29 CFR 1910.134(i)(7) · Respiratory protection
Serious$0$0May 1, 2012Closed
Citation 2, item 1 Other-than-serious$0$0May 1, 2012Closed
Citation 2, item 2
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0May 1, 2012Closed
Citation 2, item 3
29 CFR 3000403 B 3
Other-than-serious$200$150May 1, 2012Closed

Inspection 314393380 OPENED MAR 18, 2010Closed

Planned · Partial · Safety · 47 employees at the site · Closed Apr 29, 2010

3385 Highway 70e, Camden, TN 38320 · Power Boiler and Heat Exchanger Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(f)(2) · Respiratory protection
Other-than-serious$0$0Apr 1, 2010Closed
Citation 1, item 2
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Other-than-serious$0$0Apr 1, 2010Closed

Inspection 310706742 OPENED FEB 8, 2007Closed

Planned · Complete · Safety · 70 employees at the site · Closed May 21, 2007

3385 Highway 70e, Camden, TN 38320 · Power Boiler and Heat Exchanger Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$800$600Mar 14, 2007Closed
Citation 1, item 2
29 CFR 1910.37(a)(2) · Exit routes
Serious$800$600Mar 14, 2007Closed
Citation 1, item 3
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Serious$1,000$750Mar 14, 2007Closed
Citation 1, item 4
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,000$750Mar 14, 2007Closed
Citation 2, item 1
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$100$100Mar 14, 2007Closed
Citation 2, item 2
29 CFR 1910.23(a)(8) · Guarding floor and wall openings and holes
Other-than-serious$0$0Mar 14, 2007Closed
Citation 2, item 3
29 CFR 1910.37(b)(2) · Exit routes
Other-than-serious$0$0Mar 14, 2007Closed
Citation 2, item 4a
29 CFR 1910.101(b) · Compressed gases (general requirements)
Other-than-serious$100$100Mar 14, 2007Closed
Citation 2, item 4b
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Other-than-serious$0$0Mar 14, 2007Closed
Citation 2, item 5
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Mar 14, 2007Closed
Citation 2, item 6
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$100$100Mar 14, 2007Closed
10 older inspections

Inspection 308704048 OPENED FEB 16, 2005Closed

Planned · Complete · Health · 55 employees at the site · Closed Oct 28, 2005

3385 Highway 70e, Camden, TN 38320 · Power Boiler and Heat Exchanger Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(e)(2) · Spray painting and finishing
Serious$1,500$1,125Aug 1, 2005Closed
Citation 1, item 2a
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Serious$1,750$1,313Aug 1, 2005Closed
Citation 1, item 2b
29 CFR 1910.134(h)(1)(i) · Respiratory protection
Serious$0$0Aug 1, 2005Closed
Citation 1, item 2c
29 CFR 1910.134(h)(2)(i) · Respiratory protection
Serious$0$0Aug 1, 2005Closed
Citation 1, item 3a
29 CFR 1910.146(c)(1) · Permit-required confined spaces
Serious$2,000$1,500Aug 1, 2005Closed
Citation 1, item 3b
29 CFR 1910.146(c)(4) · Permit-required confined spaces
Serious$0$0Aug 1, 2005Closed
Citation 1, item 3c
29 CFR 1910.146(h)(1) · Permit-required confined spaces
Serious$0$0Aug 1, 2005Closed
Citation 1, item 3d
29 CFR 1910.146(i)(1) · Permit-required confined spaces
Serious$0$0Aug 1, 2005Closed
Citation 1, item 3e
29 CFR 1910.146(k)(2)(i) · Permit-required confined spaces
Serious$0$0Aug 1, 2005Closed
Citation 1, item 3f
29 CFR 1910.146(k)(2)(iii) · Permit-required confined spaces
Serious$0$0Aug 1, 2005Closed
Citation 1, item 3g
29 CFR 1910.146(k)(3)(i) · Permit-required confined spaces
Serious$0$0Aug 1, 2005Closed
Citation 1, item 4a
29 CFR 1910.303(g)(1)(i) · Electrical equipment, general requirements
Serious$1,750$1,313Aug 1, 2005Closed
Citation 1, item 4b
29 CFR 1910.305(a)(1)(i) · Electrical wiring methods
Serious$0$0Aug 1, 2005Closed
Citation 1, item 4c
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$0$0Aug 1, 2005Closed
Citation 1, item 4d
29 CFR 1910.305(b)(2) · Electrical wiring methods
Serious$0$0Aug 1, 2005Closed
Citation 1, item 5a
29 CFR 1000702 B 01
Serious$2,000$1,500Aug 1, 2005Closed
Citation 1, item 5b
29 CFR 1000702 D
Serious$0$0Aug 1, 2005Closed
Citation 1, item 5c
29 CFR 1910.134(a)(2) · Respiratory protection
Serious$0$0Aug 1, 2005Closed
Citation 2, item 1
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Repeat$200$150Aug 1, 2005Closed
Citation 3, item 1
29 CFR 1910.133(a)(5) · Eye and face protection
Other-than-serious$125$94Aug 1, 2005Closed
Citation 3, item 2
29 CFR 1910.179(b)(5) · Overhead and gantry cranes
Other-than-serious$250$188Aug 1, 2005Closed
Citation 3, item 3a
29 CFR 1910.1200(f)(5)(ii) · Hazard communication
Other-than-serious$375$281Aug 1, 2005Closed
Citation 3, item 3b
29 CFR 9000602
Other-than-serious$0$0Aug 1, 2005Closed

Inspection 306127309 OPENED JAN 21, 2003Closed

Planned · Complete · Safety · 52 employees at the site · Closed Apr 2, 2003

3385 Highway 70e, Camden, TN 38320 · Power Boiler and Heat Exchanger Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$500$500Feb 6, 2003Closed
Citation 1, item 1b
29 CFR 1910.305(b)(2) · Electrical wiring methods
Serious$0$0Feb 6, 2003Closed
Citation 2, item 1
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Other-than-serious$0$0Feb 6, 2003Closed
Citation 2, item 2
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Other-than-serious$0$0Feb 6, 2003Closed

Inspection 114482755 OPENED MAY 1, 1997Closed

Complaint · Partial · Health · 60 employees at the site · Closed Nov 11, 1997

3385 Highway 70e, Camden, TN 38320 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$300$300Jul 9, 1997Closed
Citation 1, item 2a
29 CFR 1910.1030(c)(1)(i) · Bloodborne pathogens
Serious$400$400Jul 9, 1997Closed
Citation 1, item 2b
29 CFR 1910.1030(g)(2)(i) · Bloodborne pathogens
Serious$0$0Jul 9, 1997Closed
Citation 1, item 3a
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Serious$400$400Jul 9, 1997Closed
Citation 1, item 3b
29 CFR 1910.1200(g)(1) · Hazard communication
Serious$0$0Jul 9, 1997Closed
Citation 1, item 3c
29 CFR 1910.1200(g)(8) · Hazard communication
Serious$0$0Jul 9, 1997Closed
Citation 1, item 3d
29 CFR 90007
Serious$0$0Jul 9, 1997Closed
Citation 2, item 1
29 CFR 1910.38(a)(1) · Emergency action plans
Other-than-serious$100$100Jul 9, 1997Closed
Citation 2, item 2a
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Serious$100$100Jul 9, 1997Closed
Citation 2, item 2b
29 CFR 1910.132(f)(1) · Personal protective equipment, general requirements
Other-than-serious$0$0Jul 9, 1997Closed
Citation 2, item 3 Serious$0$0Jul 9, 1997Closed
Citation 2, item 4
29 CFR 1910.215(a)(1) · Grinders and abrasive wheels
Other-than-serious$100$100Jul 9, 1997Closed
Citation 2, item 5
29 CFR 1910.253(b)(4)(i) · Gas welding and cutting
Other-than-serious$0$0Jul 9, 1997Closed

Inspection 114495211 OPENED SEP 1, 1992Closed

Planned · Complete · Safety · 100 employees at the site · Closed Nov 24, 1992

3385 Highway 70e, Camden, TN 38320 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1910.23(d)(1)(ii) · Guarding floor and wall openings and holes
Serious$300$300Sep 22, 1992Closed
Citation 2, item 1
29 CFR 1910.106(e)(2)(ivd) · Flammable liquids
Other-than-serious$0$0Sep 22, 1992Closed
Citation 2, item 2
29 CFR 1910.252(b)(2)(iii) · Welding fire safety
Other-than-serious$0$0Sep 22, 1992Closed
Citation 2, item 3
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Sep 22, 1992Closed
Citation 2, item 4
29 CFR 1910.254(d)(9)(iii) · Arc welding and cutting
Other-than-serious$0$0Sep 22, 1992Closed

Inspection 105509442 OPENED MAR 3, 1988Closed

Follow-up · Partial · Safety · 75 employees at the site · Closed Mar 3, 1988

3385 Highway 70e, Camden, TN 38320 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 105509319 OPENED JAN 21, 1988Closed

Planned · Complete · Safety · 75 employees at the site · Closed Mar 7, 1988

3385 Highway 70e, Camden, TN 38320 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$200$200Jan 26, 1988Closed
Citation 2, item 1
29 CFR 1910.303(f) · Electrical equipment, general requirements
Other-than-serious$0$0Jan 26, 1988Closed
Citation 2, item 2
29 CFR 1910.303(g)(1)(iii) · Electrical equipment, general requirements
Other-than-serious$0$0Jan 26, 1988Closed

Inspection 18408229 OPENED MAY 5, 1987Closed

Planned · Complete · Health · 68 employees at the site · Closed May 22, 1987

3385 Highway 70e, Camden, TN 38320 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 18424929 OPENED SEP 9, 1986Closed

Planned · Complete · Safety · 45 employees at the site · Closed Sep 9, 1986

3385 Highway 70e, Camden, TN 38320 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 3257797 OPENED AUG 8, 1985Closed

Planned · Complete · Safety · 45 employees at the site · Closed Aug 8, 1985

3385 Highway 70e, Camden, TN 38320 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 15180524 OPENED JUL 12, 1984Closed

Planned · Complete · Safety · 45 employees at the site · Closed Jul 12, 1984

3385 Highway 70e, Camden, TN 38320 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.101(b)

(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.

29 CFR 1910.1030 · Bloodborne pathogens

29 CFR 1910.1030(c)(1)(i)

(c) Exposure control—(1) Exposure Control Plan. (i) Each employer having an employee(s) with occupational exposure as defined by paragraph (b) of this section shall establish a written Exposure Control Plan designed to eliminate or minimize employee exposure.

29 CFR 1910.1030(g)(2)(i)

(2) Information and Training. (i) The employer shall train each employee with occupational exposure in accordance with the requirements of this section. Such training must be provided at no cost to the employee and during working hours. The employer shall institute a training program and ensure employee participation in the program.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.141 · Sanitation

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.184 · Slings

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.254 · Arc welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes

29 CFR 1910.38 · Emergency action plans

29 CFR 1910.95 · Noise

Other power boiler and heat exchanger manufacturing employers in Tennessee

Alert subscribers get notified of each newly cited employer in Tennessee the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.