OSHA SearchOSHA records by employer

Panel Systems, Inc.: OSHA inspections and violations

Richmond, Virginia · Prefabricated Metal Building and Component Manufacturing · NAICS 332311

17inspections
33citation items
$12,162current penalties
Jul 26, 2021last inspection

Since 1984, OSHA inspectors have visited Panel Systems, Inc. in Virginia 17 times.

The most recent inspection opened on Jul 26, 2021 as a planned inspection, in Woodbridge.

In all, OSHA issued 33 citation items: 17 serious, 1 repeat and 15 other-than-serious.

The proposed penalties came to $15,755; today they stand at $12,162, 23% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 4 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Panel Systems, Inc. averages $2,955 across 1 cited inspection.

Panel Systems, Inc.: OSHA citation items per year, 1984 to 2021
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

248employers cited

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Panel Systems, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345415186 OPENED JUL 26, 2021Closed

Planned · Complete · Safety · 40 employees at the site · Closed Jan 10, 2022

14869 Persistence Drive, Woodbridge, VA 22191 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$2,955$2,955Sep 27, 2021Final
Citation 1, item 1b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Sep 27, 2021Final
Citation 1, item 1c
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Sep 27, 2021Final
Citation 1, item 1d
29 CFR 1910.134(k)(1) · Respiratory protection
Serious$0$0Sep 27, 2021Final
Citation 2, item 1
29 CFR 1910.305(g)(1)(iv)(c) · Electrical wiring methods
Other-than-serious$0$0Sep 27, 2021Final
Citation 2, item 2
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Sep 27, 2021Final

Inspection 317802494 OPENED JUL 9, 2014Closed

Planned · No inspection · Safety · Closed Jul 9, 2014

7900 Kincannon Place, Suite 200, Lorton, VA 22079 · Prefabricated Metal Building and Component Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 335432407 OPENED JUL 25, 2012Closed

Unprogrammed other · Partial · Safety · 6 employees at the site · Closed Sep 12, 2012

3077 Epperson Street, Quantico, VA 22134 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Other-than-serious$0$0Aug 16, 2012Final

Inspection 316103977 OPENED OCT 25, 2011Closed

Planned · Complete · Safety · 10 employees at the site · Closed Jan 9, 2012

302 N. Market St., Salem, VA 24153 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.502(b)(4) · Fall protection systems
Serious$1,225$857Dec 13, 2011Closed

Inspection 314118142 OPENED FEB 16, 2010Closed

Planned · No inspection · Safety · Closed Feb 16, 2010

14869 Persistence Drive, Woodbridge, VA 22191 · Prefabricated Metal Building and Component Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 312332364 OPENED AUG 4, 2008Closed

Planned · Complete · Safety · 30 employees at the site · Closed Oct 8, 2008

7900 Kincannon Place, Suite 200, Lorton, VA 22079 · Prefabricated Metal Building and Component Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.36(d)(1) · Exit route design
Serious$1,125$700Sep 4, 2008Closed
Citation 1, item 1b
29 CFR 1910.37(a)(3) · Exit routes
Serious$0$0Sep 4, 2008Closed
Citation 2, item 1
29 CFR 1910.37(b)(6) · Exit routes
Other-than-serious$0$0Sep 4, 2008Closed
Citation 2, item 2
29 CFR 1910.101(b) · Compressed gases (general requirements)
Other-than-serious$0$0Sep 4, 2008Closed
Citation 2, item 3
29 CFR 1910.157(c)(4) · Portable fire extinguishers
Other-than-serious$0$0Sep 4, 2008Closed

Inspection 310178173 OPENED JUL 7, 2006Closed

Planned · Partial · Safety · 43 employees at the site · Closed Aug 11, 2006

1135 Millwood Pike, Winchester, VA 22602 · Other Foundation, Structure, and Building Exterior Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$1,125$800Jul 17, 2006Closed

Inspection 306818063 OPENED OCT 28, 2003Closed

Planned · Complete · Safety · 42 employees at the site · Closed Dec 11, 2003

7900 Kincannon Place, Suite 200, Lorton, VA 22079 · Prefabricated Metal Building and Component Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Serious$500$300Nov 3, 2003Closed
Citation 1, item 1b
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Serious$0$0Nov 3, 2003Closed
Citation 2, item 1
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Nov 3, 2003Closed
9 older inspections

Inspection 300195740 OPENED AUG 6, 2003Closed

Unprogrammed related · Partial · Safety · 3 employees at the site · Closed Sep 29, 2003

Marine Marathon Facility, Bldg 3399, Quantico, VA 22134 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.50(c) · Medical services and first aid
Serious$525$350Aug 19, 2003Final
Citation 1, item 1b
29 CFR 1926.50(d)(1) · Medical services and first aid
Serious$0$0Aug 19, 2003Final

Inspection 303243752 OPENED MAR 1, 2000Closed

Unprogrammed related · Complete · Safety · 40 employees at the site · Closed Feb 1, 2001

4502 Ford Ave., Arlington, VA 22202 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1910.178(i)(1)(i) · Forklifts and other powered industrial trucks
Serious$7,000$4,900Aug 25, 2000Final

Inspection 105724306 OPENED NOV 28, 1990Closed

Planned · Complete · Safety · 2 employees at the site · Closed Dec 12, 1990

24050 Woodbridge Parkway, Leesburg, VA 22075 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 105726772 OPENED JUL 5, 1990Closed

Planned · Partial · Safety · 4 employees at the site · Closed Sep 3, 1990

1980 Daniel Stuart Square (market At Opitz Cross.), Woodbridge, VA 22191 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(8) · Scaffolds, general requirements
Other-than-serious$0$0Aug 30, 1990Closed

Inspection 18736348 OPENED NOV 16, 1987Closed

Planned · Complete · Safety · 6 employees at the site · Closed Jan 29, 1988

8180 Greensboro Drive, Mclean, VA 22102 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.150(c)(1) · Fire protection
Other-than-serious$0$0Dec 29, 1987Closed

Inspection 15239403 OPENED DEC 21, 1984Closed

Follow-up · No inspection · Safety · Closed Dec 26, 1984

7th & Marshall Sts, Richmond, VA 23219 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 17387150 OPENED SEP 26, 1984Closed

Planned · Complete · Safety · 12 employees at the site · Closed Jan 4, 1985

7th & Marshall Sts, Richmond, VA 23219 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.350(j) · Gas welding and cutting
Repeat$160$160Nov 5, 1984Closed

Inspection 15234362 OPENED MAY 24, 1984Closed

Referral · Complete · Safety · 22 employees at the site · Closed Nov 28, 1988

500 E Broad St, Richmond, VA 23219 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$200$200Jun 21, 1984Closed
Citation 1, item 2
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Serious$640$640Jun 21, 1984Closed
Citation 1, item 3a
29 CFR 1926.451(e)(10) · Scaffolds, general requirements
Serious$300$300Jun 21, 1984Closed
Citation 1, item 3b
29 CFR 1926.451(e)(4) · Scaffolds, general requirements
Serious$0$0Jun 21, 1984Closed
Citation 2, item 1
29 CFR 1926.104(c) · Safety belts, lifelines, and lanyards
Other-than-serious$0$0Jun 21, 1984Closed
Citation 2, item 2
29 CFR 1926.153(j) · Liquefied petroleum gas (LP-Gas)
Other-than-serious$0$0Jun 21, 1984Closed
Citation 2, item 3
29 CFR 1926.350(a)(9) · Gas welding and cutting
Other-than-serious$0$0Jun 21, 1984Closed
Citation 2, item 4
29 CFR 1926.350(j) · Gas welding and cutting
Other-than-serious$0$0Jun 21, 1984Closed
Citation 2, item 5
29 CFR 1926.401(j)(1) · [Reserved]
Other-than-serious$0$0Jun 21, 1984Closed

Inspection 12618294 OPENED JAN 4, 1984Closed

Planned · Complete · Health · 22 employees at the site · Closed Apr 8, 1984

7764 G Fullerton Road, Springfield, VA 22122 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.1025(d)(2) · Lead in general industry
Other-than-serious$0$0Mar 29, 1984Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.101(b)

(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.

29 CFR 1910.1025 · Lead in general industry

29 CFR 1910.1025(d)(2)

(2) Initial determination. Each employer who has a workplace or work operation covered by this standard shall determine if any exployee may be exposed to lead at or above the action level.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.22 · General requirements

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.36 · Exit route design

29 CFR 1910.37 · Exit routes

29 CFR 1926.104 · Safety belts, lifelines, and lanyards

29 CFR 1926.150 · Fire protection

29 CFR 1926.153 · Liquefied petroleum gas (LP-Gas)

29 CFR 1926.350 · Gas welding and cutting

29 CFR 1926.401 · [Reserved]

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.50 · Medical services and first aid

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

Other prefabricated metal building and component manufacturing employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.