Parts Authority, LLC: OSHA inspections and violations
Bangor, Maine · Automotive Parts and Accessories Stores · NAICS 441310
1inspections
8citation items
$29,688current penalties
Jul 11, 2023last inspection
Parts Authority, LLC has one OSHA inspection on record in Maine.
OSHA opened it on Jul 11, 2023 on a referral, in Bangor.
From that inspection OSHA issued 8 citation items: 7 serious and 1 other-than-serious.
OSHA proposed $42,412 in penalties. After settlements and reviews the total is $29,688, down 30%.
Most often, OSHA cited 1910.157, portable fire extinguishers (4 items).
For context, across all retail employers the median penalty per cited inspection since 2015 is $1,750. Parts Authority, LLC averages $29,688 over 1 cited inspection in that time.
Parts Authority, LLC also files yearly injury logs with OSHA, summarized below.
It reported 1 severe injury to OSHA since 2015.
Citation items per year, by inspection date.
Maine · latest 90 days of OSHA records
34employers cited
Get notified the morning OSHA posts each new citation in Maine: the employer, the site address, the rules broken and the penalty.
OSHA records show Parts Authority, LLC at 15 sites in 6 states. Together they've had 24 inspections and $209,712 in current penalties.
We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.
Included with any plan: the site-by-site record for all 15 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Bangor site logged 0 recordable injuries or illnesses among about 19 workers: 0.0 per 100 full-time workers, against a median of 3.7 for its industry.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Parts Authority - ME - 361 - Bangor
Bangor · 2025
19
0
0
0.0
3.7
ME-Bangor
Bangor · 2023
27
2
2
10.9
3.7
Included with any plan: 1 more yearly log from these sites, back to 2023, with each site's average rate over its latest three years. Already a subscriber? Sign in.
An employee was using a chop saw to cut a one-eighth inch wire cable. The wire became entangled with the saw and the cable was pulled in. The employee's fingers were caught in the cable, resulting in partial amputations to the left index, ring, and little finger.
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
(c) General requirements. (1) The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury.
29 CFR 1910.157(e)(2)
(2) Portable extinguishers or hose used in lieu thereof under paragraph (d)(3) of this section shall be visually inspected monthly.
29 CFR 1910.157(e)(3)
(3) The employer shall assure that portable fire extinguishers are subjected to an annual maintenance check. Stored pressure extinguishers do not require an internal examination. The employer shall record the annual maintenance date and retain this record for one year after the last entry or the life of the shell, whichever is less. The record shall be available to the Assistant Secretary upon request.
29 CFR 1910.178 · Forklifts and other powered industrial trucks
Alert subscribers get notified of each newly cited employer in Maine the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.