OSHA has inspected Peterson Company once in Colorado.

The inspection began on Jan 9, 2024 after a complaint, in Wheat Ridge.

That inspection ended with 17 citation items: 11 serious and 6 other-than-serious.

Penalties were first proposed at $38,717 and now stand at $19,360, 50% lower after settlements or reviews.

Welding fire safety comes up most often in these citations: 4 items under 1910.252.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Peterson Company averages $19,360 (1 cited inspection).

Peterson Company: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

136employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch Peterson Company and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347202772 OPENED JAN 9, 2024Closed

Complaint · Partial · Health · 25 employees at the site · Closed Oct 10, 2024

10700 50th Ave., Wheat Ridge, CO 80033 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$4,839$2,420Jun 26, 2024Final
Citation 1, item 2
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$8,067$4,040Jun 26, 2024Final
Citation 1, item 3a
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$4,839$2,420Jun 26, 2024Final
Citation 1, item 3b
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Serious$0$0Jun 26, 2024Final
Citation 1, item 4
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$9,680$4,840Jun 26, 2024Final
Citation 1, item 5a
29 CFR 1910.252(a)(1)(i) · Welding fire safety
Serious$6,453$3,220Jun 26, 2024Final
Citation 1, item 5b
29 CFR 1910.252(a)(2)(ix) · Welding fire safety
Serious$0$0Jun 26, 2024Final
Citation 1, item 5c
29 CFR 1910.252(a)(2)(xiii)(a) · Welding fire safety
Serious$0$0Jun 26, 2024Final
Citation 1, item 6a
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Serious$4,839$2,420Jun 26, 2024Final
Citation 1, item 6b
29 CFR 1910.253(b)(5)(ii)(i) · Gas welding and cutting
Serious$0$0Jun 26, 2024Final
Citation 1, item 6c
29 CFR 1910.253(b)(5)(ii)(g) · Gas welding and cutting
Serious$0$0Jun 26, 2024Final
Citation 2, item 1a
29 CFR 1910.134(c) · Respiratory protection
Other-than-serious$0$0Jun 26, 2024Final
Citation 2, item 1b
29 CFR 1910.134(g)(1)(i)(a) · Respiratory protection
Other-than-serious$0$0Jun 26, 2024Final
Citation 2, item 1c
29 CFR 1910.134(k) · Respiratory protection
Other-than-serious$0$0Jun 26, 2024Final
Citation 2, item 2
29 CFR 1910.212(b) · Machine guarding
Other-than-serious$0$0Jun 26, 2024Final
Citation 2, item 3a
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Jun 26, 2024Final
Citation 2, item 3b
29 CFR 1910.252(c)(1)(iv) · Welding fire safety
Other-than-serious$0$0Jun 26, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)

(c) After completing the test exercises, the test administrator must question each test subject regarding the comfort of the respirator. When a test subject states that the respirator is unacceptable, the employer must ensure that the test administrator repeats the protocol using another respirator model.

29 CFR 1910.134(g)(1)(i)(a)

(A) Facial hair that comes between the sealing surface of the facepiece and the face or that interferes with valve function; or

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.253 · Gas welding and cutting

OSH Act Section 5 · General Duty Clause

Other fabricated structural metal manufacturing employers in Colorado

Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.