OSHA SearchOSHA records by employer

Peterson Products, Inc.: OSHA inspections and violations

Dayton, Nevada · All Other Plastics Product Manufacturing · NAICS 326199

12inspections
39citation items
$55,310current penalties
Jul 25, 2025last inspection

OSHA has inspected Peterson Products, Inc. 12 times in Nevada since 2017.

The latest one began on Jul 25, 2025 on a referral, in Dayton.

Those inspections ended with 39 citation items: 18 serious, 4 repeat and 17 other-than-serious.

Penalties were first proposed at $70,110 and now stand at $55,310, 21% lower after settlements or reviews.

Respiratory protection comes up most often in these citations: 10 items under 1910.134.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Peterson Products, Inc. averages $5,028 (11 cited inspections).

Peterson Products, Inc.: OSHA citation items per year, 2017 to 2025
Citation items per year, by inspection date.

Nevada · latest 90 days of OSHA records

112employers cited

Get notified the morning OSHA posts each new citation in Nevada: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Nevada

Checking a subcontractor, a client or your own company? Watch Peterson Products, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348398009 OPENED JUL 25, 2025Closed

Referral · Partial · Safety · 11 employees at the site · Closed May 14, 2026

10 West Airpark Vista Blvd., Dayton, NV 89403 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Other-than-serious$2,837$0Dec 9, 2025Final

Inspection 348398082 OPENED JUL 25, 2025Closed

Referral · Partial · Health · 11 employees at the site · Closed May 14, 2026

10 West Airpark Vista Blvd., Dayton, NV 89403 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.138(a) · Gloves and hand protection
Serious$3,783$3,783Dec 9, 2025Final
Citation 2, item 1
29 CFR 1910.134(h)(2)(i) · Respiratory protection
Repeat$378$378Dec 9, 2025Final
Citation 2, item 2
29 CFR 1910.134(f)(2) · Respiratory protection
Repeat$944$944Dec 9, 2025Final
Citation 3, item 1
29 CFR 1910.1200(f)(6)(ii) · Hazard communication
Other-than-serious$0$0Dec 9, 2025Final

Inspection 347283087 OPENED FEB 15, 2024Closed

Planned · Complete · Safety · 20 employees at the site · Closed May 14, 2026

10 West Airpark Vista Blvd., Dayton, NV 89403 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.36(d)(1) · Exit route design
Serious$3,687$2,950Aug 2, 2024Final
Citation 1, item 2
29 CFR 1910.303(b)(7)(i) · Electrical equipment, general requirements
Serious$3,687$2,950Aug 2, 2024Final
Citation 2, item 1
29 CFR 1904.32(a)(4) · Yearly injury summary
Other-than-serious$1,000$800Aug 2, 2024Final
Citation 2, item 2
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Other-than-serious$0$0Aug 2, 2024Final
Citation 2, item 3
29 CFR 1910.305(g)(1)(iv) · Electrical wiring methods
Other-than-serious$0$0Aug 2, 2024Final

Inspection 347285934 OPENED FEB 15, 2024Closed

Planned · Complete · Health · 21 employees at the site · Closed May 14, 2026

10 West Airpark Vista Blvd., Dayton, NV 89403 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$6,452$5,162Aug 2, 2024Final
Citation 1, item 2
29 CFR LCB FILE NO. R069-20 (APPROVED AP
Serious$4,465$3,572Aug 2, 2024Final
Citation 2, item 1
29 CFR 1910.134(f)(2) · Respiratory protection
Repeat$368$294Aug 2, 2024Final
Citation 3, item 1
29 CFR 1910.106(a)(29) · Flammable liquids
Other-than-serious$0$0Aug 2, 2024Final

Inspection 345222749 OPENED MAR 24, 2021Closed

Complaint · Partial · Safety · 24 employees at the site · Closed Jun 30, 2022

10 West Airpark Vista Blvd., Dayton, NV 89403 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(d)(1)(iii) · Respiratory protection
Serious$3,901$3,901Jun 23, 2021Final
Citation 1, item 2
29 CFR 1910.1200(h)(3)(iii) · Hazard communication
Serious$5,461$5,461Jun 23, 2021Final
Citation 2, item 1
29 CFR 1910.134(f)(2) · Respiratory protection
Other-than-serious$0$0Jun 23, 2021Final
Citation 2, item 2
29 CFR 1910.134(h)(2)(i) · Respiratory protection
Other-than-serious$0$0Jun 23, 2021Final

Inspection 344456777 OPENED NOV 19, 2019Closed

Referral · Partial · Health · 15 employees at the site · Closed Oct 29, 2020

10 West Airpark Vista Blvd., Dayton, NV 89403 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$3,543$3,543Feb 4, 2020Final
Citation 1, item 2
29 CFR 1910.107(g)(2) · Spray painting and finishing
Serious$2,834$2,834Feb 4, 2020Final
Citation 2, item 1
29 CFR 1910.305(g)(1)(iv)(b) · Electrical wiring methods
Other-than-serious$0$0Feb 4, 2020Final

Inspection 344431747 OPENED NOV 6, 2019Closed

Complaint · Partial · Safety · 24 employees at the site · Closed Sep 2, 2020

10 West Airpark Vista Blvd., Dayton, NV 89403 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.333(a)(1) · Working near live electrical parts
Serious$3,220$2,254Dec 9, 2019Final
Citation 1, item 2
29 CFR 1910.335(a)(1)(i) · Safeguards for personnel protection
Serious$3,220$2,254Dec 9, 2019Final

Inspection 344313457 OPENED SEP 17, 2019Closed

Referral · Partial · Health · 26 employees at the site · Closed Nov 26, 2019

10 West Airpark Vista Blvd., Dayton, NV 89403 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(k)(6) · Respiratory protection
Other-than-serious$0$0Oct 23, 2019Final
Citation 1, item 2
29 CFR 1910.134(m)(2)(i)(c) · Respiratory protection
Other-than-serious$0$0Oct 23, 2019Final
4 older inspections

Inspection 343920534 OPENED APR 10, 2019Closed

Complaint · Partial · Health · 24 employees at the site · Closed Jul 9, 2019

10 West Airpark Vista Blvd., Dayton, NV 89403 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343923819 OPENED APR 10, 2019Closed

Complaint · Partial · Safety · 24 employees at the site · Closed Jan 24, 2020

10 West Airpark Vista Blvd., Dayton, NV 89403 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.304(b)(3)(ii)(c)(3) · Grounding and circuit protection
Serious$2,975$2,082Jul 15, 2019Final
Citation 1, item 2
29 CFR 1910.304(b)(4) · Grounding and circuit protection
Serious$2,380$1,666Jul 15, 2019Final
Citation 1, item 3
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$4,165$2,916Jul 15, 2019Final
Citation 2, item 1
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Repeat$100$70Jul 15, 2019Final
Citation 3, item 1
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Other-than-serious$0$0Jul 15, 2019Final
Citation 3, item 2
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Other-than-serious$0$0Jul 15, 2019Final

Inspection 342855558 OPENED DEC 28, 2017Closed

Referral · Complete · Safety · 49 employees at the site · Closed May 9, 2018

10 West Air Park Vista Blvd., Dayton, NV 89403 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$3,150$2,205Mar 19, 2018Final
Citation 1, item 1b
29 CFR 1910.213(d)(1) · Woodworking machinery
Serious$0$0Mar 19, 2018Final
Citation 2, item 1
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Other-than-serious$0$0Mar 19, 2018Final
Citation 2, item 2
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Other-than-serious$0$0Mar 19, 2018Final

Inspection 342812740 OPENED NOV 30, 2017Closed

Complaint · Complete · Health · 45 employees at the site · Closed Aug 22, 2018

10 West Airpark Vista Blvd., Dayton, NV 89403 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$3,780$2,646Mar 19, 2018Final
Citation 1, item 2
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$3,150$2,205Mar 19, 2018Final
Citation 2, item 1
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Mar 19, 2018Final
Citation 3, item 1
29 CFR NEVADA REVISED STATUTES 618.383(1
Other-than-serious$630$441Mar 19, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.32 · Yearly injury summary

29 CFR 1904.32(a)(4)

(4) Post the annual summary.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(a)(29)

(29) Safety can shall mean an approved container, of not more than 5 gallons capacity, having a spring-closing lid and spout cover and so designed that it will safely relieve internal pressure when subjected to fire exposure.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.138 · Gloves and hand protection

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.333 · Working near live electrical parts

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.335 · Safeguards for personnel protection

29 CFR 1910.36 · Exit route design

Other all other plastics product manufacturing employers in Nevada

Alert subscribers get notified of each newly cited employer in Nevada the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.