Inspection 348651555 OPENED DEC 18, 2025Closed
6176 East Molloy Road, East Syracuse, NY 13057 · Electronic Connector Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
East Syracuse, New York · Electronic Connector Manufacturing · NAICS 334417
Since 2015, OSHA inspectors have visited PPC Broadband in New York 3 times.
The most recent inspection opened on Dec 18, 2025 on a referral, in East Syracuse.
In all, OSHA issued 7 citation items: 6 serious and 1 other-than-serious.
The proposed penalties came to $38,148; today they stand at $26,704, 30% less.
The rule cited most here is 1910.147 (lockout/tagout), 4 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. PPC Broadband averages $13,352 across 2 cited inspections.
PPC Broadband also files yearly injury logs with OSHA, summarized below.
It reported 1 severe injury to OSHA since 2015.
Want to know if OSHA cites PPC Broadband again? Add it to a watchlist and we will email you the morning the citation shows up.
Watch this company6176 East Molloy Road, East Syracuse, NY 13057 · Electronic Connector Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
6176 East Molloy Road, East Syracuse, NY 13057 · Electronic Connector Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Serious | $8,287 | $5,801 | Aug 26, 2022 | Final |
| Citation 1, item 2a 29 CFR 1910.147(c)(6)(i) · Lockout/tagout |
Serious | $8,287 | $5,801 | Aug 26, 2022 | Final |
| Citation 1, item 2b 29 CFR 1910.147(c)(6)(i)(c) · Lockout/tagout |
Serious | $0 | $0 | Aug 26, 2022 | Final |
| Citation 1, item 3 29 CFR 1910.147(c)(7)(i)(a) · Lockout/tagout |
Serious | $8,287 | $5,801 | Aug 26, 2022 | Final |
| Citation 1, item 4 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $8,287 | $5,801 | Aug 26, 2022 | Final |
| Citation 2, item 1 29 CFR 1904.41(a)(1) · Electronic submission of Employer Identification Number (EIN) and injury and illness records to OSHA |
Other-than-serious | $0 | $0 | Aug 26, 2022 | Final |
6176 East Molloy Road, East Syracuse, NY 13057 · Electronic Connector Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $5,000 | $3,500 | Mar 11, 2015 | Final |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2020, the East Syracuse site logged 1 recordable injury or illness among about 359 workers: 0.3 per 100 full-time workers, against a median of 0.5 for its industry. Those cases cost 43 days away from work.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| PPC Broadband East Syracuse · 2020 | 359 | 1 | 1 | 0.3 | 0.5 |
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.
Jan 30, 2015, East Syracuse: Amputation · amputations · finger(s), fingernail(s), n.e.c.
An employee was polishing a spindle on a lathe using an emery cloth. A keyway slot on the shaft caught his right index finger, resulting in an amputation of the finger. There was no bone loss.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1904.41(a)(1)
(a) Basic requirements—(1) Annual electronic submission of information from OSHA Form 300A Summary of Work-Related Injuries and Illnesses. (i) If your establishment had 20-249 employees at any time during the previous calendar year, and your establishment is classified in an industry listed in appendix A to subpart E of this part, then you must electronically submit information from OSHA Form 300A Summary of Work-Related Injuries and Illnesses to OSHA or OSHA's designee. You must submit the information once a year, no later than the date listed in paragraph (c) of this section of the year after the calendar year covered by the form.
29 CFR 1910.147(c)(4)(i)
(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.
29 CFR 1910.147(c)(6)(i)
(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.