OSHA SearchOSHA records by employer

Northeastern Electronics Co., Inc: OSHA inspections and violations

Elbridge, New York · Electronic Connector Manufacturing · NAICS 334417

4inspections
7citation items
$9,481current penalties
Aug 21, 2025last inspection

OSHA has inspected Northeastern Electronics Co., Inc 4 times in New York since 1987.

The latest one began on Aug 21, 2025 as a planned inspection, in Elbridge.

Those inspections ended with 7 citation items: 7 serious.

Penalties were first proposed at $14,586 and now stand at $9,481, 35% lower after settlements or reviews.

Lead in general industry comes up most often in these citations: 3 items under 1910.1025.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Northeastern Electronics Co., Inc averages $9,481 (1 cited inspection).

Northeastern Electronics Co., Inc: OSHA citation items per year, 1987 to 2025
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

356employers cited

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Northeastern Electronics Co., Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348456583 OPENED AUG 21, 2025Closed

Planned · No inspection · Safety · 1 employee at the site · Closed Aug 21, 2025

102 State Route 5 West, Elbridge, NY 13060 · Electronic Connector Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343617718 OPENED NOV 20, 2018Closed

Complaint · Partial · Safety · 40 employees at the site · Closed Feb 19, 2021

102 State Route 5 West, Elbridge, NY 13060 · Electronic Connector Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$6,630$4,309Mar 12, 2019Final
Citation 1, item 2
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$3,978$2,586Mar 12, 2019Final
Citation 1, item 3a
29 CFR 1910.1025(h)(1) · Lead in general industry
Serious$3,978$2,586Mar 12, 2019Final
Citation 1, item 3b
29 CFR 1910.1025(l)(1)(i) · Lead in general industry
Serious$0$0Mar 12, 2019Final
Citation 1, item 3c
29 CFR 1910.1025(m)(1)(iii) · Lead in general industry
Serious$0$0Mar 12, 2019Final
Citation 1, item 3d
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$0$0Mar 12, 2019Final
Citation 1, item 3e
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Mar 12, 2019Final

Inspection 309378040 OPENED DEC 13, 2005Closed

Planned · No inspection · Safety · 35 employees at the site · Closed Dec 22, 2005

102 Rte. 5 West, Elbridge, NY 13060 · Other Electronic Component Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 100528538 OPENED JUL 14, 1987Closed

Complaint · Partial · Safety · 20 employees at the site · Closed Jul 14, 1987

101 Pickard Drive, Syracuse, NY 13211 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1025 · Lead in general industry

29 CFR 1910.1025(h)(1)

(h) Housekeeping—(1) Surfaces. All surfaces shall be maintained as free as practicable of accumulations of lead.

29 CFR 1910.1025(l)(1)(i)

(l) Employee information and training—(1) Training program. (i) Each employer who has a workplace in which there is a potential exposure to airborne lead at any level shall inform employees of the content of Appendices A and B of this regulation.

29 CFR 1910.1025(m)(1)(iii)

(iii) Employers shall include lead in the hazard communication program established to comply with the HCS (§ 1910.1200). Employers shall ensure that each employee has access to labels on containers of lead and to safety data sheets, and is trained in accordance with the requirements of HCS and paragraph (l) of this section.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.212 · Machine guarding

29 CFR 1910.303 · Electrical equipment, general requirements

Other electronic connector manufacturing employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.