Inspection 348749094 OPENED JAN 27, 2026Closed
221 Sw Broadway, Ocala, FL 34475 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 1990, OSHA inspectors have visited Pre-Con Construction, Inc in Florida 7 times.
The most recent inspection opened on Jan 27, 2026 as a planned inspection, in Ocala.
In all, OSHA issued 14 citation items: 8 serious and 6 other-than-serious.
The proposed penalties came to $33,954; today they stand at $23,182, 32% less.
The rule cited most here is 1926.502 (fall protection systems), 3 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Pre-Con Construction, Inc averages $11,021 across 2 cited inspections.
Want to know if OSHA cites Pre-Con Construction, Inc again? Add it to a watchlist and we will email you the morning the citation shows up.
Watch this company221 Sw Broadway, Ocala, FL 34475 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
111 W Oak Ave 2002 Tampa Ave, Tampa, FL 33609 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1655 Prudential Dr, Jacksonville, FL 32207 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(12) · Fall protection in construction |
Other-than-serious | $8,873 | $8,873 | Apr 4, 2017 | Final |
| Citation 1, item 2a 29 CFR 1926.502(g)(1)(ii) · Fall protection systems |
Other-than-serious | $8,873 | $0 | Apr 4, 2017 | Final |
| Citation 1, item 2b 29 CFR 1926.502(g)(3)(i) · Fall protection systems |
Other-than-serious | $0 | $0 | Apr 4, 2017 | Final |
| Citation 1, item 2c 29 CFR 1926.502(g)(3)(ii) · Fall protection systems |
Other-than-serious | $0 | $0 | Apr 4, 2017 | Final |
| Citation 1, item 3 29 CFR 1926.1053(b)(4) · Ladders in construction |
Serious | $6,338 | $3,169 | Apr 4, 2017 | Final |
3800 Nw 115th Avenue, Doral, FL 33166 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 OSH Act Section 5(a)(1) · General Duty Clause |
Serious | $8,730 | $10,000 | Sep 15, 2016 | Final |
4000 Central Florida Blvd, Orlando, FL 32816 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.404(f)(6) · Ground-fault protection on job sites |
Other-than-serious | $0 | $0 | Dec 7, 2012 | Final |
8675 Commodity Circle, Orlando, FL 33457 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 2a 29 CFR 1926.1052(a)(3) · Stairways in construction |
Serious | $900 | $900 | Feb 25, 2003 | Closed |
| Citation 1, item 2b 29 CFR 1926.1052(b)(1) · Stairways in construction |
Serious | $0 | $0 | Feb 25, 2003 | Closed |
| Citation 1, item 2c 29 CFR 1926.1052(c)(1) · Stairways in construction |
Serious | $0 | $0 | Feb 25, 2003 | Closed |
| Citation 1, item 2d 29 CFR 1926.26 · Illumination |
Serious | $0 | $0 | Feb 25, 2003 | Closed |
Orlando International Airport, Orlando, FL 32822 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.59(e)(1) · Hazard communication |
Serious | $120 | $120 | Jul 10, 1990 | Closed |
| Citation 1, item 2 29 CFR 1926.59(g)(1) · Hazard communication |
Serious | $120 | $120 | Jul 10, 1990 | Closed |
| Citation 2, item 1 29 CFR 1926.20(b)(1) · Construction safety programs |
Other-than-serious | $0 | $0 | Jul 10, 1990 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.1052(a)(3)
(3) Riser height and tread depth shall be uniform within each flight of stairs, including any foundation structure used as one or more treads of the stairs. Variations in riser height or tread depth shall not be over 1/4-inch (0.6 cm) in any stairway system.
29 CFR 1926.1052(b)(1)
(1) Except during stairway construction, foot traffic is prohibited on stairways with pan stairs where the treads and/or landings are to be filled in with concrete or other material at a later date, unless the stairs are temporarily fitted with wood or other solid material at least to the top edge of each pan. Such temporary treads and landings shall be replaced when worn below the level of the top edge of the pan.
29 CFR 1926.1052(c)(1)
(1) Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with:
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.