OSHA SearchOSHA records by employer

Productive Plastics, Inc.: OSHA inspections and violations

Mount Laurel, New Jersey · Unlaminated Plastics Profile Shape Manufacturing · NAICS 326121

6inspections
21citation items
$16,255current penalties
Nov 13, 2024last inspection

OSHA has inspected Productive Plastics, Inc. 6 times in New Jersey since 1986.

The latest one began on Nov 13, 2024 as a planned inspection, in Mount Laurel.

Those inspections ended with 21 citation items: 16 serious and 5 other-than-serious.

Penalties were first proposed at $25,638 and now stand at $16,255, 37% lower after settlements or reviews.

Lockout/tagout comes up most often in these citations: 5 items under 1910.147.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Productive Plastics, Inc. averages $3,350 (2 cited inspections).

Productive Plastics, Inc. also files yearly injury logs with OSHA, summarized below.

Productive Plastics, Inc.: OSHA citation items per year, 1986 to 2024
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

269employers cited

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch Productive Plastics, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347875031 OPENED NOV 13, 2024Closed

Planned · Complete · Safety · 67 employees at the site · Closed Feb 6, 2025

103 W. Park Drive, Mount Laurel, NJ 08054 · Unlaminated Plastics Profile Shape Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 2, item 1
29 CFR 1910.1200(f)(5) · Hazard communication
Other-than-serious$0$0Jan 29, 2025Final

Inspection 346389877 OPENED DEC 13, 2022Closed

Referral · Partial · Safety · 68 employees at the site · Closed Jan 7, 2025

103 W. Park Drive, Mount Laurel, NJ 08054 · Unlaminated Plastics Profile Shape Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(d)(2) · Lockout/tagout
Serious$10,938$6,700May 16, 2023Final

Inspection 338855232 OPENED FEB 13, 2013Closed

Planned · Complete · Safety · 33 employees at the site · Closed Nov 3, 2014

103 W. Park Drive, Mount Laurel, NJ 08054 · Unlaminated Plastics Profile Shape Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$2,100$1,470Mar 22, 2013Final
Citation 1, item 1b
29 CFR 1910.147(c)(7)(i)(a) · Lockout/tagout
Serious$0$0Mar 22, 2013Final
Citation 1, item 2
29 CFR 1910.178(g)(2) · Forklifts and other powered industrial trucks
Serious$2,100$1,470Mar 22, 2013Final

Inspection 310364427 OPENED NOV 6, 2006Closed

Planned · Complete · Safety · 55 employees at the site · Closed Oct 3, 2007

103-105 West Park Drive, Mt Laurel, NJ 08054 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.133(b)(1) · Eye and face protection
Serious$1,250$788Dec 8, 2006Closed
Citation 1, item 2
29 CFR 1910.146(c)(1) · Permit-required confined spaces
Serious$1,250$788Dec 8, 2006Closed
Citation 1, item 3
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$1,250$788Dec 8, 2006Closed
Citation 1, item 4
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$1,250$788Dec 8, 2006Closed
Citation 1, item 5
29 CFR 1910.157(g)(2) · Portable fire extinguishers
Serious$750$472Dec 8, 2006Closed
Citation 1, item 6
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$1,250$788Dec 8, 2006Closed
Citation 1, item 7
29 CFR 1910.212(b) · Machine guarding
Serious$750$472Dec 8, 2006Closed
Citation 1, item 8
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$1,250$788Dec 8, 2006Closed
Citation 1, item 9a
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Serious$750$472Dec 8, 2006Closed
Citation 1, item 9b
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$0$0Dec 8, 2006Closed
Citation 1, item 10a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$750$472Dec 8, 2006Closed
Citation 1, item 10b
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Dec 8, 2006Closed
Citation 2, item 1
29 CFR 1904.32(b)(2) · Yearly injury summary
Other-than-serious$0$0Dec 8, 2006Closed
Citation 2, item 2
29 CFR 1910.23(d)(1)(iv) · Guarding floor and wall openings and holes
Other-than-serious$0$0Dec 8, 2006Closed
Citation 2, item 3
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Dec 8, 2006Closed
Citation 2, item 4
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Dec 8, 2006Closed

Inspection 310020326 OPENED JUN 13, 2006Closed

Planned · No inspection · Safety · 60 employees at the site · Closed Jun 13, 2006

103-105 West Park Drive, Mt Laurel, NJ 08054 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 100166214 OPENED MAY 5, 1986Closed

Planned · Complete · Safety · 40 employees at the site · Closed May 5, 1986

14 Roland Avenue, Mt. Laurel, NJ 08054 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Mt. Laurel site logged 3 recordable injuries or illnesses among about 47 workers: 5.1 per 100 full-time workers, against a median of 2.6 for its industry. Those cases cost 195 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Productive Plastics, Inc.
Mt. Laurel · 2025
47 315.12.6
Productive Plastics, Inc.
Mount Laurel · 2017
56 12217.82.6

Included with any plan: 4 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.32 · Yearly injury summary

29 CFR 1904.32(b)(2)

(2) How do I complete the annual summary? You must:

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.1200(f)(5)

(f) Any organic peroxide which, in laboratory testing, neither detonates in the cavitated state nor deflagrates at all and shows only a low or no effect when heated under confinement as well as low or no explosive power shall be defined as organic peroxide TYPE F;

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

Other unlaminated plastics profile shape manufacturing employers in New Jersey

Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.