OSHA SearchOSHA records by employer

Profus Construction Corp.: OSHA inspections and violations

Chicago, Illinois · Masonry Contractors · NAICS 238140

13inspections
59citation items
$121,383current penalties
May 15, 2026last inspection

Since 2000, OSHA inspectors have visited Profus Construction Corp. in Illinois 13 times.

The most recent inspection opened on May 15, 2026, in Chicago and is still open.

In all, OSHA issued 59 citation items: 43 serious, 10 repeat and 6 other-than-serious.

The proposed penalties came to $133,463; today they stand at $121,383, 9% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 11 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,079 penalty. Profus Construction Corp. averages $14,251 across 5 cited inspections.

Profus Construction Corp.: OSHA citation items per year, 2000 to 2026
Citation items per year, by inspection date.

Want to know if OSHA cites Profus Construction Corp. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 348940735 OPENED MAY 15, 2026Open

Inspection · Partial · Safety · 7 employees at the site · Open

2206 W Lawrence Avenue, Chicago, IL 60625 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$5,958$5,958Aug 26, 2026Contested
Citation 1, item 2a
29 CFR 1926.502(d)(1) · Fall protection systems
Serious$5,958$5,958Aug 26, 2026Contested
Citation 1, item 2b
29 CFR 1926.502(d)(17) · Fall protection systems
Serious$0$0Aug 26, 2026Contested
Citation 1, item 3
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$5,107$5,107Aug 26, 2026Contested
Citation 1, item 4a
29 CFR 1926.1052(c)(1)(i) · Stairways in construction
Serious$4,256$4,256Aug 26, 2026Contested
Citation 1, item 4b
29 CFR 1926.1052(c)(12) · Stairways in construction
Serious$0$0Aug 26, 2026Contested
Citation 2, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Repeat$6,809$6,809Aug 26, 2026Contested
Citation 2, item 2a
29 CFR 1926.501(b)(1) · Fall protection in construction
Repeat$11,916$11,916Aug 26, 2026Contested
Citation 2, item 2b
29 CFR 1926.501(b)(3) · Fall protection in construction
Repeat$0$0Aug 26, 2026Contested

Inspection 348941600 OPENED MAY 15, 2026Open

Inspection · Partial · Health · 10 employees at the site · Open

2206 W Lawrence Avenue, Chicago, IL 60625 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.1153(c)(1) · Silica dust in construction
Serious$5,958$5,958Aug 26, 2026Contested
Citation 1, item 1b
29 CFR 1926.1153(d)(2)(i) · Silica dust in construction
Serious$0$0Aug 26, 2026Contested

Inspection 346002934 OPENED JUN 7, 2022Closed

Planned · Partial · Safety · 9 employees at the site · Closed Apr 3, 2025

2816 N Southport Ave, Chicago, IL 60657 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$3,108$3,108Oct 6, 2022Final
Citation 1, item 2a
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$4,351$4,351Oct 6, 2022Final
Citation 1, item 2b
29 CFR 1926.501(b)(3) · Fall protection in construction
Serious$0$0Oct 6, 2022Final
Citation 2, item 1
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Oct 6, 2022Final
Citation 3, item 1
29 CFR 1903.19(c)(1) · Proving cited hazards were fixed
Other-than-serious$349$349Jan 10, 2023Final

Inspection 342907599 OPENED JAN 26, 2018Closed

Planned · Partial · Safety · 6 employees at the site · Closed Oct 13, 2020

216 S. Green St., Chicago, IL 60607 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$2,956$2,956Apr 27, 2018Final
Citation 1, item 2
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$2,956$2,956Apr 27, 2018Final
Citation 1, item 3
29 CFR 1926.1053(a)(1)(ii) · Ladders in construction
Serious$2,956$2,956Apr 27, 2018Final
Citation 2, item 1
29 CFR 1903.19(c)(1) · Proving cited hazards were fixed
Other-than-serious$415$415Sep 5, 2018Final

Inspection 342917184 OPENED JAN 26, 2018Closed

Unprogrammed other · Partial · Health · 6 employees at the site · Closed Oct 11, 2019

216 S. Green St., Chicago, IL 60607 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.95(a) · Criteria for personal protective equipment
Serious$2,956$1,500May 9, 2018Final
Citation 1, item 1b
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$0$0May 9, 2018Final
Citation 1, item 2a
29 CFR 1926.1153(c)(1) · Silica dust in construction
Serious$3,696$6,500May 9, 2018Final
Citation 1, item 2b
29 CFR 1926.1153(d)(2)(i) · Silica dust in construction
Serious$0$0May 9, 2018Final
Citation 1, item 2c
29 CFR 1926.1153(g)(1)(i) · Silica dust in construction
Serious$3,696$0May 9, 2018Final
Citation 1, item 2d
29 CFR 1926.1153(g)(1)(ii) · Silica dust in construction
Serious$0$0May 9, 2018Final
Citation 1, item 2e
29 CFR 1926.1153(i)(1) · Silica dust in construction
Serious$3,696$0May 9, 2018Final
Citation 1, item 2f
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0May 9, 2018Final
Citation 2, item 1
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Other-than-serious$0$0May 9, 2018Final
Citation 2, item 2
29 CFR 1910.1200(g)(1) · Hazard communication
Other-than-serious$414$200May 9, 2018Final

Inspection 338563034 OPENED JAN 29, 2013Closed

Planned · Partial · Safety · 10 employees at the site · Closed Feb 14, 2014

3764 N. Clark Str., Chicago, IL 60613 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$2,200$2,200Mar 25, 2013Final
Citation 2, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Repeat$6,160$6,160Mar 25, 2013Final
Citation 2, item 2
29 CFR 1926.1052(c)(1)(i) · Stairways in construction
Repeat$3,520$3,520Mar 25, 2013Final
Citation 3, item 1
29 CFR 1903.19(c)(1) · Proving cited hazards were fixed
Other-than-serious$440$440Jun 13, 2013Final

Inspection 314604885 OPENED JUN 30, 2010Closed

Planned · Partial · Safety · 4 employees at the site · Closed Dec 2, 2013

2517 N. Southport Ave., Chicago, IL 60614 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Repeat$10,000$10,000Sep 3, 2010Closed

Inspection 312599467 OPENED SEP 17, 2009Closed

Planned · Complete · Safety · 8 employees at the site · Closed Oct 13, 2011

1215 Harlem Ave., Berwyn, IL 60402 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$1,000$1,000Nov 18, 2009Closed
Citation 1, item 1b
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$0$0Nov 19, 2009Closed
Citation 2, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Repeat$4,000$4,000Nov 19, 2009Closed
5 older inspections

Inspection 312592058 OPENED JAN 6, 2009Closed

Unprogrammed other · Complete · Safety · 7 employees at the site · Closed Apr 20, 2009

1254 W. Jackson Bvld, Chicago, IL 60607 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.34(a) · Means of egress
Serious$750$250Feb 25, 2009Closed
Citation 1, item 1b
29 CFR 1926.56(a) · Illumination
Serious$0$0Feb 25, 2009Closed
Citation 1, item 2a
29 CFR 1926.1052(b)(1) · Stairways in construction
Serious$1,050$350Feb 25, 2009Closed
Citation 1, item 2b
29 CFR 1926.1052(c)(1)(i) · Stairways in construction
Serious$0$0Feb 25, 2009Closed
Citation 1, item 2c
29 CFR 1926.1052(c)(12) · Stairways in construction
Serious$0$0Feb 25, 2009Closed
Citation 1, item 3
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,500$500Feb 25, 2009Closed
Citation 2, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Repeat$1,200$400Feb 25, 2009Closed

Inspection 312403850 OPENED JUL 31, 2008Closed

Planned · Partial · Safety · 9 employees at the site · Closed Nov 3, 2008

3554 Paris, Chicago, IL 60634 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$600$420Sep 23, 2008Closed
Citation 1, item 2
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$450$315Sep 23, 2008Closed
Citation 1, item 3a
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$1,500$1,050Sep 23, 2008Closed
Citation 1, item 3b
29 CFR 1926.451(g)(4)(xv) · Scaffolds, general requirements
Serious$0$0Sep 23, 2008Closed
Citation 1, item 4
29 CFR 1926.454(a) · Scaffold training
Serious$750$525Sep 23, 2008Closed

Inspection 305993115 OPENED DEC 13, 2002Closed

Planned · Partial · Safety · 5 employees at the site · Closed Mar 19, 2009

217-221 S. Leavitt, Chicago, IL 60612 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$2,000$2,000Feb 14, 2003Closed
Citation 2, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Repeat$10,000$10,000Feb 14, 2003Closed

Inspection 305216145 OPENED JUL 10, 2002Closed

Planned · Partial · Safety · 9 employees at the site · Closed Jul 23, 2003

1829 West Iowa, Chicago, IL 60622 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(c)(1) · Scaffolds, general requirements
Serious$1,000$1,000Jul 24, 2002Closed
Citation 1, item 2
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Repeat$4,000$4,000Jul 24, 2002Closed

Inspection 303123848 OPENED SEP 21, 2000Closed

Planned · Partial · Safety · 5 employees at the site · Closed Feb 22, 2001

1450 N. Artesian, Chicago, IL 60622 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(1) · Construction safety programs
Serious$450$200Feb 1, 2001Closed
Citation 1, item 2
29 CFR 1926.100(a) · Hard hats in construction
Serious$382$200Feb 1, 2001Closed
Citation 1, item 3
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,500$800Feb 1, 2001Closed
Citation 1, item 4a
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$1,500$800Feb 1, 2001Closed
Citation 1, item 4b
29 CFR 1926.454(a)(1) · Scaffold training
Serious$0$0Feb 1, 2001Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.19 · Proving cited hazards were fixed

29 CFR 1903.19(c)(1)

(c) Abatement certification. (1) Within 10 calendar days after the abatement date, the employer must certify to OSHA (the Agency) that each cited violation has been abated, except as provided in paragraph (c)(2) of this section.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)(i)

(i) A list of the hazardous chemicals known to be present using a product identifier that is referenced on the appropriate safety data sheet (the list may be compiled for the workplace as a whole or for individual work areas); and,

29 CFR 1910.1200(g)(1)

(g) Safety data sheets. (1) Chemical manufacturers and importers shall obtain or develop a safety data sheet for each hazardous chemical they produce or import. Employers shall have a safety data sheet in the workplace for each hazardous chemical which they use.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1153 · Silica dust in construction

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.34 · Means of egress

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.56 · Illumination

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

29 CFR 1926.95 · Criteria for personal protective equipment

Other masonry contractors employers in Illinois

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.