OSHA SearchOSHA records by employer

Progressive Service Die Company: OSHA inspections and violations

Jacksonville, North Carolina · Special Die and Tool, Die Set, Jig, and Fixture Manufacturing · NAICS 333514

5inspections
64citation items
$26,750current penalties
Feb 18, 2015last inspection

Progressive Service Die Company has 5 OSHA inspections on record in North Carolina, the first in 1994.

OSHA's last visit started on Feb 18, 2015 after a complaint, in Jacksonville.

Across those inspections OSHA issued 64 citation items: 45 serious and 19 other-than-serious.

OSHA proposed $26,750 in penalties and the amount has not been reduced.

Most often, OSHA cited 1910.215, grinders and abrasive wheels (14 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Progressive Service Die Company averages $4,950 over 1 cited inspection in that time.

Progressive Service Die Company: OSHA citation items per year, 1994 to 2015
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

226employers cited

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Progressive Service Die Company and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 317947356 OPENED FEB 18, 2015Closed

Complaint · Partial · Safety · 18 employees at the site · Closed Jul 17, 2015

217 White Street, Jacksonville, NC 28456 · Special Die and Tool, Die Set, Jig, and Fixture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$2,100$2,100May 13, 2015Closed
Citation 1, item 2
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$1,500$1,500May 13, 2015Closed
Citation 1, item 3
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$450$450May 13, 2015Closed
Citation 1, item 4
29 CFR 1910.215(a)(2) · Grinders and abrasive wheels
Serious$900$900May 13, 2015Closed
Citation 2, item 1
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0May 13, 2015Closed

Inspection 305726374 OPENED OCT 21, 2002Closed

Planned · Complete · Safety · 30 employees at the site · Closed Dec 10, 2002

217 White St., Jacksonville, NC 28546 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$500$500Oct 31, 2002Closed
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$250$250Oct 31, 2002Closed
Citation 1, item 3a
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Serious$700$700Oct 31, 2002Closed
Citation 1, item 3b
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$0$0Oct 31, 2002Closed
Citation 1, item 3c
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Serious$0$0Oct 31, 2002Closed
Citation 1, item 3d
29 CFR 1910.334(a)(3)(i) · Using electrical equipment
Serious$0$0Oct 31, 2002Closed
Citation 1, item 3e
29 CFR 1910.334(a)(3)(iii) · Using electrical equipment
Serious$0$0Oct 31, 2002Closed
Citation 1, item 4
29 CFR 1910.307(b) · Hazardous (classified) locations
Serious$500$500Oct 31, 2002Closed
Citation 2, item 1
29 CFR 1910.147(c)(1) · Lockout/tagout
Other-than-serious$0$0Oct 31, 2002Closed
Citation 2, item 2
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Oct 31, 2002Closed
Citation 2, item 3
29 CFR 1910.178(q)(7) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Oct 31, 2002Closed
Citation 2, item 4
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Oct 31, 2002Closed
Citation 2, item 5
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Oct 31, 2002Closed

Inspection 302868542 OPENED JUL 6, 1999Closed

Planned · Complete · Safety · 16 employees at the site · Closed Aug 24, 1999

217 White St., Jacksonville, NC 28546 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$350$350Aug 3, 1999Closed
Citation 1, item 2a
29 CFR 1910.215(a)(2) · Grinders and abrasive wheels
Serious$250$250Aug 3, 1999Closed
Citation 1, item 2b
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$0$0Aug 3, 1999Closed
Citation 1, item 2c
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Aug 3, 1999Closed
Citation 1, item 2d
29 CFR 1910.215(d)(1) · Grinders and abrasive wheels
Serious$0$0Aug 3, 1999Closed
Citation 1, item 3a
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Serious$125$125Aug 3, 1999Closed
Citation 2, item 1
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Aug 3, 1999Closed
Citation 2, item 2
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Aug 3, 1999Closed
Citation 2, item 3a
29 CFR 1910.304(a)(2) · Grounding and circuit protection
Other-than-serious$0$0Aug 3, 1999Closed
Citation 2, item 3b
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Other-than-serious$0$0Aug 3, 1999Closed
Citation 2, item 3c
29 CFR 1910.305(b)(2) · Electrical wiring methods
Other-than-serious$0$0Aug 3, 1999Closed

Inspection 111111365 OPENED DEC 21, 1994Closed

Referral · Partial · Safety · 30 employees at the site · Closed Jul 25, 1995

217 White St., Jacksonville, NC 28546 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$2,250$2,250Feb 2, 1995Closed
Citation 1, item 2a
29 CFR 1910.215(a)(2) · Grinders and abrasive wheels
Serious$1,350$1,350Feb 2, 1995Closed
Citation 1, item 2b
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$0$0Feb 2, 1995Closed
Citation 1, item 2c
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$0$0Feb 1, 1995Closed
Citation 1, item 2d
29 CFR 1910.215(b)(3) · Grinders and abrasive wheels
Serious$0$0Feb 2, 1995Closed
Citation 1, item 3a
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$2,250$2,250Feb 2, 1995Closed
Citation 1, item 3b
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Feb 2, 1995Closed
Citation 1, item 3c
29 CFR 1910.215(d)(1) · Grinders and abrasive wheels
Serious$0$0Feb 2, 1995Closed
Citation 1, item 4
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$1,575$1,575Feb 2, 1995Closed

Inspection 125286567 OPENED OCT 27, 1994Closed

Complaint · Partial · Health · 30 employees at the site · Closed Oct 27, 1995

217 White St., Jacksonville, NC 28546 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$4,200$4,200Mar 10, 1995Closed
Citation 1, item 1b Serious$0$0Mar 10, 1995Closed
Citation 1, item 1c Serious$0$0Mar 10, 1995Closed
Citation 1, item 1d Serious$0$0Mar 10, 1995Closed
Citation 1, item 1e Serious$0$0Mar 10, 1995Closed
Citation 1, item 1f Serious$0$0Mar 10, 1995Closed
Citation 1, item 1g Serious$0$0Mar 10, 1995Closed
Citation 1, item 2a
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Serious$2,100$2,100Mar 10, 1995Closed
Citation 1, item 2b
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Serious$0$0Mar 10, 1995Closed
Citation 1, item 2c
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Serious$0$0Mar 10, 1995Closed
Citation 1, item 2d
29 CFR 1910.106(d)(4)(iv) · Flammable liquids
Serious$0$0Mar 10, 1995Closed
Citation 1, item 2e
29 CFR 1910.106(d)(4)(v) · Flammable liquids
Serious$0$0Mar 10, 1995Closed
Citation 1, item 2f
29 CFR 1910.106(d)(6)(iv) · Flammable liquids
Serious$0$0Mar 10, 1995Closed
Citation 1, item 3a
29 CFR 1910.107(e)(2) · Spray painting and finishing
Serious$900$900Mar 10, 1995Closed
Citation 1, item 3b
29 CFR 1910.107(g)(2) · Spray painting and finishing
Serious$0$0Mar 10, 1995Closed
Citation 1, item 4
29 CFR 1910.110(b)(6)(vi) · Storage and handling of liquefied petroleum gases
Serious$2,100$2,100Mar 10, 1995Closed
Citation 1, item 5
29 CFR 1910.138(a) · Gloves and hand protection
Serious$900$900Mar 10, 1995Closed
Citation 1, item 6
29 CFR 1910.252(a)(2)(ix) · Welding fire safety
Serious$900$900Mar 10, 1995Closed
Citation 2, item 1
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$600$600Mar 10, 1995Closed
Citation 2, item 2a
29 CFR 1910.134(b)(3) · Respiratory protection
Other-than-serious$0$0Mar 10, 1995Closed
Citation 2, item 2b
29 CFR 1910.134(b)(1) · Respiratory protection
Other-than-serious$0$0Mar 10, 1995Closed
Citation 2, item 2c
29 CFR 1910.134(b)(10) · Respiratory protection
Other-than-serious$0$0Mar 10, 1995Closed
Citation 2, item 2d
29 CFR 1910.134(b)(11) · Respiratory protection
Other-than-serious$0$0Mar 10, 1995Closed
Citation 2, item 3a
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Other-than-serious$0$0Mar 10, 1995Closed
Citation 2, item 3b
29 CFR 1910.1200(f)(5)(ii) · Hazard communication
Other-than-serious$0$0Mar 10, 1995Closed
Citation 2, item 3c
29 CFR 1910.1200(g)(1) · Hazard communication
Other-than-serious$0$0Mar 10, 1995Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.2 · Partial exemption for establishments in certain industries

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.106(d)(4)(iv)

(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.

29 CFR 1910.106(d)(4)(v)

(v) Storage in inside storage rooms. In every inside storage room there shall be maintained one clear aisle at least 3 feet wide. Containers over 30 gallons capacity shall not be stacked one upon the other. Dispensing shall be by approved pump or self-closing faucet only.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.138 · Gloves and hand protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.22 · General requirements

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.307 · Hazardous (classified) locations

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.95 · Noise

Other special die and tool, die set, jig, and fixture manufacturing employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.