OSHA SearchOSHA records by employer

Pulau Corporation: OSHA inspections and violations

Fort Cavazos, Texas · Other Electronic and Precision Equipment Repair and Maintenance · NAICS 811219

1inspections
2citation items
$28,962current penalties
Mar 6, 2025last inspection

OSHA has inspected Pulau Corporation once in Texas.

The inspection began on Mar 6, 2025 after a fatality or catastrophe, in Fort Cavazos.

That inspection ended with 2 citation items: 2 serious.

Penalties were first proposed at $33,100 and now stand at $28,962, 12% lower after settlements or reviews.

Lockout/tagout comes up most often in these citations: 2 items under 1910.147.

How that compares: the median penalty per cited inspection for repair and personal services employers since 2015 is $1,200, and Pulau Corporation averages $28,962 (1 cited inspection).

1 inspection on this page followed a fatal incident.

Pulau Corporation: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Pulau Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348099391 OPENED MAR 6, 2025Closed

Fatality or catastrophe · Partial · Safety · 394 employees at the site · Closed Mar 17, 2026

Clabber Creek Range, Fort Cavazos, TX 76544 · Other Electronic and Precision Equipment Repair and Maintenance · OSHA's record · Phone and website on Google Maps

Incident on Mar 6, 2025 (fatal): Falling range target asphyxiates employee

An employee was working to realign a plywood target attached to a stationary armor target lift machine. The stationary armor target lift machine was present, and the plywood target was in the up position for employee to perform maintenance. The stationary armor target lift machine was requested to be offline. While the employee was using a hand impact tool to tighten bolts for the repositioned plywood target, the stationary armor target lift machine arms holding the plywood target came down pinning the employee causing fatal injuries.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Serious$16,550$16,550Aug 22, 2025Final
Citation 1, item 3
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$16,550$12,412Aug 22, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(ii)

(ii) The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:

29 CFR 1910.147(c)(6)(i)

(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.

Other other electronic and precision equipment repair and maintenance employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.