OSHA SearchOSHA records by employer

Quasar Energy Group: OSHA inspections and violations

Sheffield Village, Ohio · All Other Basic Organic Chemical Manufacturing · NAICS 325199

2inspections
4citation items
$25,726current penalties
Jun 15, 2022last inspection

Since 2015, OSHA inspectors have visited Quasar Energy Group in Ohio 2 times.

The most recent inspection opened on Jun 15, 2022 on a referral, in Wooster.

In all, OSHA issued 4 citation items: 3 serious and 1 other-than-serious.

The proposed penalties came to $34,302; today they stand at $25,726, 25% less.

The rule cited most here is 1910.132 (personal protective equipment, general requirements), 2 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Quasar Energy Group averages $12,863 across 2 cited inspections.

1 inspection on this page followed a fatal incident.

Quasar Energy Group: OSHA citation items per year, 2015 to 2022
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

265employers cited

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch Quasar Energy Group and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346022627 OPENED JUN 15, 2022Closed

Referral · Partial · Safety · 2 employees at the site · Closed Feb 12, 2023

2072 Secrest Road, Wooster, OH 44691 · Other Electric Power Generation · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$10,151$7,613Dec 5, 2022Final
Citation 1, item 3
29 CFR 1910.307(c) · Hazardous (classified) locations
Serious$10,151$7,613Dec 5, 2022Final

Inspection 340622398 OPENED MAY 11, 2015Closed

Fatality or catastrophe · Partial · Safety · 85 employees at the site · Closed Mar 4, 2016

2350 Abbe Rd., Sheffield Village, OH 44054 · All Other Basic Organic Chemical Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on May 9, 2015 (fatal): Employee dies from fall off of an elevated tank rim

At 9:00 a.m. on May 9, 2015, an employee was working alone and had accessed the upper rim of a 30 foot methane producing digester tank to inspect and repair the tanks deflated rubber roof membrane. While using a portable ladder, the employee either slipped or lost their balance near the unguarded north side of the narrow tank rim and fell approximately 30 feet to the ground below. The employee died at the hospital several hours later.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Serious$7,000$7,000Jul 22, 2015Final
Citation 1, item 2
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Other-than-serious$7,000$3,500Jul 22, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.132(a)

(a) Application. Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, shall be provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact.

29 CFR 1910.132(d)(1)

(d) Hazard assessment and equipment selection. (1) The employer shall assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE). If such hazards are present, or likely to be present, the employer shall:

29 CFR 1910.307 · Hazardous (classified) locations

29 CFR 1910.307(c)

(c) Electrical installations. Equipment, wiring methods, and installations of equipment in hazardous (classified) locations shall be intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location. Requirements for each of these options are as follows:

OSH Act Section 5 · General Duty Clause

Other all other basic organic chemical manufacturing employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.