OSHA SearchOSHA records by employer

Rabon Enterprises: OSHA inspections and violations

Columbia, South Carolina · Masonry Contractors · NAICS 238140

33inspections
78citation items
$16,330current penalties
Feb 3, 2020last inspection

OSHA has inspected Rabon Enterprises 33 times in South Carolina since 2002.

The latest one began on Feb 3, 2020 as a planned inspection, in Charleston.

Those inspections ended with 78 citation items: 48 serious and 30 other-than-serious.

Penalties were first proposed at $24,850 and now stand at $16,330, 34% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 36 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Rabon Enterprises averages $875 (4 cited inspections).

Rabon Enterprises also files yearly injury logs with OSHA, summarized below.

Rabon Enterprises: OSHA citation items per year, 2002 to 2020
Citation items per year, by inspection date.

South Carolina · latest 90 days of OSHA records

43employers cited

Get notified the morning OSHA posts each new citation in South Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in South Carolina

Checking a subcontractor, a client or your own company? Watch Rabon Enterprises and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344618301 OPENED FEB 3, 2020Closed

Planned · Partial · Safety · 3 employees at the site · Closed Aug 20, 2020

4066 W Wildcat Blvd, Charleston, SC 29414 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$875$875Mar 4, 2020Final
Citation 1, item 2
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$875$875Mar 4, 2020Final

Inspection 343244133 OPENED JUN 19, 2018Closed

Planned · Complete · Safety · 50 employees at the site · Closed Jan 2, 2019

2327 Springvale Rd, Ridgeway, SC 29130 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$750$750Nov 29, 2018Final

Inspection 342143799 OPENED FEB 22, 2017Closed

Planned · Complete · Safety · 20 employees at the site · Closed May 17, 2017

735 Pine Ridge Dr., West Columbia, SC 29172 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1.12(A)
Serious$750$750Apr 21, 2017Final

Inspection 340908664 OPENED AUG 12, 2015Closed

Referral · Partial · Health · 18 employees at the site · Closed Feb 24, 2016

9995 Miles Jamison Rd, Ladson, SC 29456 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(l)(1) · Respiratory protection
Other-than-serious$250$250Dec 2, 2015Final

Inspection 317889574 OPENED DEC 31, 2014Closed

Follow-up · Partial · Safety · 19 employees at the site · Closed Feb 4, 2015

2327 Springvale Rd, Ridgeway, SC 29130 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 317498947 OPENED OCT 1, 2014Closed

Complaint · Partial · Health · 6 employees at the site · Closed Aug 28, 2015

1300 Spratt Street, Fort Mill, SC 29715 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 317498962 OPENED SEP 30, 2014Closed

Planned · Complete · Safety · 19 employees at the site · Closed Feb 4, 2015

2000 Knobcone Avenue, North Augusta, SC 29841 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Oct 14, 2014Closed

Inspection 317493682 OPENED APR 8, 2014Closed

Planned · Complete · Safety · 6 employees at the site · Closed May 20, 2014

2060 Dobys Bridge Road, Fort Mill, SC 29715 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$300$300May 6, 2014Closed
25 older inspections

Inspection 317005056 OPENED APR 23, 2013Closed

Planned · Complete · Safety · 12 employees at the site · Closed Sep 30, 2013

3 Par Drive, Johnston, SC 29832 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$900$450May 17, 2013Closed
Citation 1, item 5a
29 CFR 1926.451(f)(14) · Scaffolds, general requirements
Serious$0$450May 17, 2013Closed
Citation 1, item 5b
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0May 17, 2013Closed

Inspection 316622448 OPENED JAN 8, 2013Closed

Planned · Complete · Safety · 19 employees at the site · Closed Mar 7, 2013

11629 Broad River Rd, Chapin, SC 29036 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.300(b)(2) · Tools—Hand and Power: general requirements
Serious$450$450Feb 5, 2013Closed
Citation 1, item 2
29 CFR 1926.451(f)(4) · Scaffolds, general requirements
Serious$600$600Feb 5, 2013Closed
Citation 1, item 3
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$600$600Feb 5, 2013Closed

Inspection 316622026 OPENED DEC 18, 2012Closed

Planned · Complete · Safety · 11 employees at the site · Closed Feb 28, 2013

449 Rutland Drive Northwest, Aiken, SC 29801 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.300(b)(2) · Tools—Hand and Power: general requirements
Serious$500$500Jan 28, 2013Closed
Citation 2, item 1
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Other-than-serious$0$0Jan 28, 2013Closed

Inspection 316203355 OPENED APR 18, 2012Closed

Planned · Complete · Safety · 25 employees at the site · Closed Aug 28, 2012

916 Mount Vernon Church Rd, Chapin, SC 29036 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(b)(1) · Job-site wiring
Serious$600$300Jun 22, 2012Closed
Citation 1, item 2
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$600$300Jun 22, 2012Closed

Inspection 315184762 OPENED NOV 23, 2010Closed

Planned · Complete · Safety · 6 employees at the site · Closed Jan 18, 2011

449 Rimer Pond Road, Blythewood, SC 29016 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 3, item 1
29 CFR 1926.152(d)(4) · Flammable liquids
Other-than-serious$0$0Jan 5, 2011Closed
Citation 3, item 2
29 CFR 1926.152(g)(9) · Flammable liquids
Other-than-serious$0$0Jan 5, 2011Closed
Citation 3, item 3
29 CFR 1926.602(c)(1)(vi) · Earthmovers and forklifts in construction
Other-than-serious$0$0Jan 5, 2011Closed

Inspection 314696956 OPENED OCT 27, 2010Closed

Planned · Complete · Safety · 4 employees at the site · Closed Dec 6, 2010

2621 Clemson Road, Columbia, SC 29229 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$375$375Nov 23, 2010Closed
Citation 2, item 1
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Other-than-serious$0$0Nov 23, 2010Closed
Citation 2, item 2
29 CFR 1926.602(c)(1)(vi) · Earthmovers and forklifts in construction
Other-than-serious$0$0Nov 23, 2010Closed

Inspection 314084211 OPENED MAY 5, 2010Closed

Planned · Complete · Safety · 2 employees at the site · Closed Sep 20, 2010

692 Mill St, Little Mountain, SC 29075 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 5, item 1
29 CFR 1926.300(b)(2) · Tools—Hand and Power: general requirements
Serious$375$150Jul 16, 2010Closed
Citation 5, item 2
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$625$250Jul 16, 2010Closed
Citation 5, item 3
29 CFR 1926.451(b)(5)(i) · Scaffolds, general requirements
Serious$625$250Jul 16, 2010Closed
Citation 5, item 4
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$625$250Jul 16, 2010Closed
Citation 5, item 5
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$625$250Jul 16, 2010Closed
Citation 5, item 6
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$625$250Jul 16, 2010Closed
Citation 5, item 7a
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$625$250Jul 16, 2010Closed
Citation 5, item 7b
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Jul 16, 2010Closed
Citation 5, item 7c
29 CFR 1926.454(b) · Scaffold training
Serious$0$0Jul 16, 2010Closed
Citation 6, item 1
29 CFR 30040
Other-than-serious$0$0Jul 16, 2010Closed

Inspection 314080391 OPENED MAR 4, 2010Closed

Planned · Complete · Safety · 8 employees at the site · Closed Mar 7, 2012

350 Old Manning Rd, Sumter, SC 29150 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 3, item 1
29 CFR 1926.300(b)(2) · Tools—Hand and Power: general requirements
Serious$675$675Apr 9, 2010Contested
Citation 3, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$600$600Apr 9, 2010Contested
Citation 3, item 3
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$600$600Apr 9, 2010Contested
Citation 4, item 1
29 CFR 30040
Other-than-serious$0$0Apr 9, 2010Contested
Citation 4, item 2
29 CFR 1926.602(c)(1)(vi) · Earthmovers and forklifts in construction
Other-than-serious$0$0Apr 9, 2010Contested

Inspection 313488371 OPENED OCT 27, 2009Closed

Planned · Complete · Safety · 40 employees at the site · Closed Mar 26, 2010

3825 N Jeffries Hwy, Walterboro, SC 29488 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.300(b)(2) · Tools—Hand and Power: general requirements
Serious$675$270Dec 18, 2009Closed
Citation 2, item 1
29 CFR 1926.152(g)(9) · Flammable liquids
Other-than-serious$0$0Dec 18, 2009Closed

Inspection 312171770 OPENED DEC 16, 2008Closed

Planned · Complete · Safety · 4 employees at the site · Closed Mar 9, 2009

450 Old Swamp Rd, Swansea, SC 29160 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.300(b)(2) · Tools—Hand and Power: general requirements
Serious$250$100Jan 15, 2009Closed
Citation 2, item 1
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Jan 15, 2009Closed

Inspection 311509541 OPENED JAN 8, 2008Closed

Planned · Complete · Safety · 14 employees at the site · Closed Feb 8, 2008

377 Cy Shumpert Rd, Prosperity, SC 29129 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 3, item 1
29 CFR 1926.28(a) · Personal protective equipment
Other-than-serious$0$0Jan 24, 2008Closed

Inspection 310973664 OPENED SEP 6, 2007Closed

Planned · Complete · Safety · 11 employees at the site · Closed Dec 19, 2007

1315 Boston Ave, West Columbia, SC 29170 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.95(a) · Criteria for personal protective equipment
Serious$450$180Oct 4, 2007Closed
Citation 1, item 2
29 CFR 1926.300(b)(2) · Tools—Hand and Power: general requirements
Serious$675$270Oct 4, 2007Closed
Citation 1, item 3
29 CFR 1926.451(b)(4) · Scaffolds, general requirements
Serious$900$360Oct 4, 2007Closed
Citation 1, item 4
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$900$360Oct 4, 2007Closed
Citation 1, item 5
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$900$360Oct 4, 2007Closed
Citation 2, item 1
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Oct 4, 2007Closed
Citation 2, item 2
29 CFR 1926.28(a) · Personal protective equipment
Other-than-serious$0$0Oct 4, 2007Closed
Citation 2, item 3
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Other-than-serious$0$0Oct 4, 2007Closed
Citation 2, item 4
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Other-than-serious$0$0Oct 4, 2007Closed

Inspection 310968979 OPENED JUN 22, 2007Closed

Follow-up · Partial · Safety · 13 employees at the site · Closed Jul 9, 2007

7435 Monticello Rd, Columbia, SC 29207 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 310334941 OPENED FEB 28, 2007Closed

Planned · Partial · Safety · 6 employees at the site · Closed Jun 1, 2007

6340 Platt Springs Rd, Lexington, SC 29073 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 3, item 1
29 CFR 10012 A
Serious$750$300Mar 22, 2007Closed
Citation 3, item 5a
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$240Mar 22, 2007Closed
Citation 3, item 5b
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Mar 22, 2007Closed
Citation 3, item 5c
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$0$0Mar 22, 2007Closed

Inspection 310337936 OPENED JAN 23, 2007Closed

Planned · Complete · Safety · 13 employees at the site · Closed Jul 9, 2007

7435 Monticello Rd, Columbia, SC 29207 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$600$240Feb 6, 2007Closed
Citation 1, item 2
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$750$300Feb 6, 2007Closed
Citation 1, item 3
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$750$300Feb 6, 2007Closed
Citation 2, item 1
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Feb 6, 2007Closed
Citation 2, item 2
29 CFR 1910.1200(f)(5) · Hazard communication
Other-than-serious$0$0Feb 6, 2007Closed

Inspection 308234913 OPENED FEB 8, 2005Closed

Follow-up · Partial · Safety · 16 employees at the site · Closed Feb 22, 2005

10901 Wilson Blvd., Blythewood, SC 29016 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 308235530 OPENED JAN 27, 2005Closed

Planned · Complete · Safety · 24 employees at the site · Closed May 4, 2005

1601 Clarkson Road, Hopkins, SC 29601 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 4, item 1
29 CFR 1926.300(b)(2) · Tools—Hand and Power: general requirements
Serious$675$270Feb 22, 2005Closed
Citation 5, item 1
29 CFR 1926.21(b)(2) · Construction safety training
Other-than-serious$0$0Feb 22, 2005Closed

Inspection 308235712 OPENED JAN 27, 2005Closed

Planned · Partial · Safety · 8 employees at the site · Closed Apr 26, 2005

1835 Camden Hwy, Sumter, SC 29151 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 3, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$600$240Feb 7, 2005Closed
Citation 3, item 2
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$600$240Feb 7, 2005Closed

Inspection 308233733 OPENED NOV 2, 2004Closed

Follow-up · Partial · Safety · 14 employees at the site · Closed Nov 10, 2004

1400 Woodruff Road, Greenville, SC 29607 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 308232487 OPENED OCT 21, 2004Closed

Planned · Complete · Safety · 16 employees at the site · Closed Feb 22, 2005

10901 Wilson Blvd., Blythewood, SC 29016 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$500$500Nov 10, 2004Closed
Citation 2, item 1
29 CFR 1926.28(a) · Personal protective equipment
Other-than-serious$0$0Nov 10, 2004Closed

Inspection 307433946 OPENED APR 27, 2004Closed

Planned · Complete · Safety · 14 employees at the site · Closed Nov 10, 2004

1400 Woodruff Road, Greenville, SC 29607 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 2, item 1
29 CFR 1926.28(a) · Personal protective equipment
Other-than-serious$0$0Aug 3, 2004Closed

Inspection 301116547 OPENED MAR 18, 2004Closed

Planned · Complete · Health · 45 employees at the site · Closed Jun 9, 2004

115550 Jenkins Road, Fort Jackson, SC 29207 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$0$0Mar 29, 2004Closed
Citation 1, item 2
29 CFR 1910.134(c)(3) · Respiratory protection
Other-than-serious$0$0Mar 29, 2004Closed
Citation 1, item 3
29 CFR 1910.134(d)(1)(iii) · Respiratory protection
Other-than-serious$0$0Mar 29, 2004Closed
Citation 1, item 4
29 CFR 1910.134(e)(1) · Respiratory protection
Other-than-serious$0$0Mar 29, 2004Closed
Citation 1, item 5
29 CFR 1910.134(f)(2) · Respiratory protection
Other-than-serious$0$0Mar 29, 2004Closed

Inspection 306838749 OPENED FEB 4, 2004Closed

Planned · Partial · Safety · 12 employees at the site · Closed Mar 11, 2004

8921 Two Notch Road, Columbia, SC 29223 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$200$200Feb 26, 2004Closed
Citation 1, item 2
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$250$250Feb 26, 2004Closed

Inspection 303571657 OPENED MAR 14, 2002Closed

Planned · Complete · Safety · 11 employees at the site · Closed Apr 17, 2002

Rt 1, Hwy 151, Jefferson, SC 29718 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 3, item 1
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Other-than-serious$0$0Apr 5, 2002Closed

Inspection 303571681 OPENED MAR 14, 2002Closed

Planned · Complete · Safety · 14 employees at the site · Closed Apr 17, 2002

Hwy 9, Chesterfield, SC 29709 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Apr 5, 2002Closed
Citation 2, item 1
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Other-than-serious$0$0Apr 5, 2002Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2024, the Ridgeway site logged 0 recordable injuries or illnesses among about 32 workers: 0.0 per 100 full-time workers, against a median of 2.8 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Rabon Enterprises
Ridgeway · 2024
32 000.02.8
Rabon Enterprises, Inc.
Ridgeway · 2018
50 1028.02.8

Included with any plan: 3 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.1200(f)(5)

(f) Any organic peroxide which, in laboratory testing, neither detonates in the cavitated state nor deflagrates at all and shows only a low or no effect when heated under confinement as well as low or no explosive power shall be defined as organic peroxide TYPE F;

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1926.152 · Flammable liquids

29 CFR 1926.21 · Construction safety training

29 CFR 1926.28 · Personal protective equipment

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.602 · Earthmovers and forklifts in construction

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

29 CFR 1926.95 · Criteria for personal protective equipment

Other masonry contractors employers in South Carolina

Alert subscribers get notified of each newly cited employer in South Carolina the morning it is posted. See the alert plans.