4inspections
8citation items
$6,725current penalties
Sep 6, 2018last inspection

OSHA has inspected Randall Manufacturing LLC 4 times in Illinois since 2008.

The latest one began on Sep 6, 2018 to follow up on an earlier case, in Elmhurst.

Those inspections ended with 8 citation items: 6 serious and 2 other-than-serious.

Penalties were first proposed at $10,873 and now stand at $6,725, 38% lower after settlements or reviews.

Hazard communication comes up most often in these citations: 3 items under 1910.1200.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Randall Manufacturing LLC averages $5,325 (1 cited inspection).

Randall Manufacturing LLC also files yearly injury logs with OSHA, summarized below.

Randall Manufacturing LLC: OSHA citation items per year, 2008 to 2018
Citation items per year, by inspection date.

Illinois · latest 90 days of OSHA records

423employers cited

Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Illinois

Checking a subcontractor, a client or your own company? Watch Randall Manufacturing LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343443495 OPENED SEP 6, 2018Closed

Follow-up · Partial · Safety · 70 employees at the site · Closed Sep 6, 2018

722 N. Church Rd., Elmhurst, IL 60126 · Other Motor Vehicle Parts Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342815529 OPENED DEC 7, 2017Closed

Complaint · Partial · Safety · 70 employees at the site · Closed Jan 17, 2018

722 N. Church Rd., Elmhurst, IL 60126 · Other Motor Vehicle Parts Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$8,873$5,325Dec 27, 2017Final
Citation 2, item 1
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0Dec 27, 2017Final

Inspection 312725799 OPENED MAY 8, 2009Closed

Complaint · Partial · Health · 50 employees at the site · Closed Jun 8, 2009

722 North Church Rd., Elmhurst, IL 60126 · Unlaminated Plastics Profile Shape Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(q)(7) · Forklifts and other powered industrial trucks
Other-than-serious$250$175May 20, 2009Closed

Inspection 311252415 OPENED SEP 4, 2008Closed

Complaint · Partial · Health · 75 employees at the site · Closed Nov 5, 2008

722 N. Church Rd., Elmhurst, IL 60126 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(b)(1) · Spray painting and finishing
Serious$1,000$700Oct 3, 2008Closed
Citation 1, item 1b
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$0$0Oct 3, 2008Closed
Citation 1, item 2a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$750$525Oct 3, 2008Closed
Citation 1, item 2b
29 CFR 1910.1200(g)(8) · Hazard communication
Serious$0$0Oct 3, 2008Closed
Citation 1, item 2c
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Oct 3, 2008Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Elmhurst site logged 0 recordable injuries or illnesses among about 53 workers: 0.0 per 100 full-time workers, against a median of 2.4 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Randall Manufacturing
Elmhurst · 2025
53 000.02.4
Randall Manufacturing LLC-Church Location
Elmhurst · 2021
52 102.35.2
Randall Manufacturing LLC-Spangler Location
Elmhurst · 2019
13 118.05.2
Randall Manufacturing LLC
Elmhurst · 2017
71 212.62.7

Included with any plan: 8 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(1)

(b) Spray booths—(1) Construction. Spray booths shall be substantially constructed of steel, securely and rigidly supported, or of concrete or masonry except that aluminum or other substantial noncombustible material may be used for intermittent or low volume spraying. Spray booths shall be designed to sweep air currents toward the exhaust outlet.

29 CFR 1910.107(c)(6)

(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.303 · Electrical equipment, general requirements