Colchester, Vermont · Structural Steel and Precast Concrete Contractors · NAICS 238120

5inspections
18citation items
$1,655current penalties
Oct 27, 2015last inspection

Reliance Steel has 5 OSHA inspections on record in Vermont, the first in 1991.

OSHA's last visit started on Oct 27, 2015 on a referral, in Colchester.

Across those inspections OSHA issued 18 citation items: 13 serious and 5 other-than-serious.

OSHA proposed $2,055 in penalties. After settlements and reviews the total is $1,655, down 19%.

Most often, OSHA cited 1910.252, welding fire safety (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Reliance Steel averages $600 over 1 cited inspection in that time.

Reliance Steel also files yearly injury logs with OSHA, summarized below.

Reliance Steel: OSHA citation items per year, 1991 to 2015
Citation items per year, by inspection date.

Vermont · latest 90 days of OSHA records

25employers cited

Get notified the morning OSHA posts each new citation in Vermont: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Vermont

Checking a subcontractor, a client or your own company? Watch Reliance Steel and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341017655 OPENED OCT 27, 2015Closed

Referral · Partial · Safety · 23 employees at the site · Closed Jul 18, 2016

94 South Oak Circle, Colchester, VT 05446 · Iron and Steel Pipe and Tube Manufacturing from Purchased Steel · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1910.243(c)(3) · Guarding of portable powered tools
Serious$1,000$600Dec 22, 2015Final
Citation 2, item 1
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Dec 22, 2015Final

Inspection 305538290 OPENED JUN 1, 2005Closed

Planned · Partial · Health · 23 employees at the site · Closed Aug 2, 2005

One Main Street, Winooski, VT 05404 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$450$450Jul 15, 2005Closed
Citation 1, item 1b
29 CFR 1910.134(g)(1)(ia) · Respiratory protection
Serious$0$0Jul 15, 2005Closed
Citation 1, item 1c
29 CFR 1910.134(a)(1) · Respiratory protection
Serious$0$0Jul 15, 2005Closed
Citation 2, item 1a
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Other-than-serious$0$0Jul 15, 2005Closed
Citation 2, item 1b
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Jul 15, 2005Closed

Inspection 303449979 OPENED SEP 25, 2000Closed

Follow-up · Partial · Health · 14 employees at the site · Closed Sep 29, 2000

62 Oak Circle Drive, Colchester, VT 05446 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 302367941 OPENED DEC 3, 1999Closed

Planned · Complete · Health · 14 employees at the site · Closed Jul 12, 2000

62 Oak Circle Drive, Colchester, VT 05446 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$125$125May 12, 2000Closed
Citation 1, item 1b
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0May 12, 2000Closed
Citation 1, item 2a
29 CFR 1910.252(b)(2)(ia) · Welding fire safety
Serious$100$100May 12, 2000Closed
Citation 1, item 2b
29 CFR 1910.252(b)(2)(iii) · Welding fire safety
Serious$0$0May 12, 2000Closed
Citation 1, item 2c
29 CFR 1910.252(b)(3) · Welding fire safety
Serious$0$0May 12, 2000Closed
Citation 1, item 3a
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Serious$100$100May 12, 2000Closed
Citation 2, item 1
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Other-than-serious$0$0May 12, 2000Closed
Citation 2, item 2
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0May 12, 2000Closed

Inspection 111726147 OPENED MAR 18, 1991Closed

Planned · Complete · Safety · 10 employees at the site · Closed Apr 22, 1991

62 Oak Circle Drive, Colchester, VT 05446 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$120$120Apr 3, 1991Closed
Citation 1, item 2
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$80$80Apr 3, 1991Closed
Citation 1, item 3
29 CFR 1910.305(g)(1)(i) · Electrical wiring methods
Serious$80$80Apr 3, 1991Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2017, the Colchester site logged 2 recordable injuries or illnesses among about 24 workers: 7.5 per 100 full-time workers, against a median of 3.6 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Reliance Steel Inc.
Colchester · 2017
24 207.53.6

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.132(d)(1)

(d) Hazard assessment and equipment selection. (1) The employer shall assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE). If such hazards are present, or likely to be present, the employer shall:

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.22 · General requirements

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

Other structural steel and precast concrete contractors employers in Vermont

Alert subscribers get notified of each newly cited employer in Vermont the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.