Renfrow Hard Chrome Plating Co.: OSHA inspections and violations

Lubbock, Texas · Electroplating, Plating, Polishing, Anodizing, and Coloring · NAICS 332813

3inspections
14citation items
$4,105current penalties
May 17, 2019last inspection

OSHA has inspected Renfrow Hard Chrome Plating Co. 3 times in Texas since 1973.

The latest one began on May 17, 2019 to follow up on an earlier case, in Lubbock.

Those inspections ended with 14 citation items: 9 serious and 5 other-than-serious.

Penalties were first proposed at $8,825 and now stand at $4,105, 53% lower after settlements or reviews.

Overhead and gantry cranes comes up most often in these citations: 3 items under 1910.179.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Renfrow Hard Chrome Plating Co. averages $4,080 (1 cited inspection).

Renfrow Hard Chrome Plating Co.: OSHA citation items per year, 1973 to 2019
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

393employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Renfrow Hard Chrome Plating Co. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344016449 OPENED MAY 17, 2019Closed

Follow-up · Partial · Safety · 3 employees at the site · Closed Oct 25, 2019

13804 Hwy. 87, Lubbock, TX 79423 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341204808 OPENED JAN 27, 2016Closed

Planned · Complete · Safety · 3 employees at the site · Closed Aug 8, 2017

13804 Hwy. 87, Lubbock, TX 79423 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(b)(1) · General requirements
Serious$1,200$720Jun 24, 2016Final
Citation 1, item 2a
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$1,600$960Jun 24, 2016Final
Citation 1, item 2b
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Jun 24, 2016Final
Citation 1, item 2c
29 CFR 1910.134(k)(5) · Respiratory protection
Serious$0$0Jun 24, 2016Final
Citation 1, item 3
29 CFR 1910.151(c) · First aid and eyewash
Other-than-serious$2,000$0Jun 24, 2016Final
Citation 1, item 4a
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Serious$2,000$1,200Jun 24, 2016Final
Citation 1, item 4b
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Serious$0$0Jun 24, 2016Final
Citation 1, item 5a
29 CFR 1910.179(l)(3)(iii)(c) · Overhead and gantry cranes
Serious$2,000$1,200Jun 24, 2016Final
Citation 1, item 5b
29 CFR 1910.179(j)(2)(iii) · Overhead and gantry cranes
Serious$0$0Jun 24, 2016Final
Citation 1, item 5c
29 CFR 1910.179(j)(2)(iv) · Overhead and gantry cranes
Serious$0$0Jun 24, 2016Final

Inspection 16955908 OPENED OCT 11, 1973Closed

Planned · Complete · Health · 5 employees at the site · Closed Mar 10, 1984

Tahoka Hwy And 134 St, Lubbock, TX 79401 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.157(d)(3)(i) · Portable fire extinguishers
Other-than-serious$0$0Oct 26, 1973Closed
Citation 1, item 2
29 CFR 1910.252(a)(2)(iib)(0) · Welding fire safety
Other-than-serious$25$25Oct 26, 1973Closed
Citation 1, item 3 Other-than-serious$0$0Oct 26, 1973Closed
Citation 1, item 4 Other-than-serious$0$0Oct 26, 1973Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(e)(1)

(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.

29 CFR 1910.134(f)(2)

(2) Deep breathing. In a normal standing position, the subject shall breathe slowly and deeply, taking caution so as not to hyperventilate.

29 CFR 1910.134(k)(5)

(5) Retraining shall be administered annually, and when the following situations occur:

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.22 · General requirements

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.309

Other electroplating, plating, polishing, anodizing, and coloring employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.