Inspection 341567584 OPENED JUN 21, 2016Closed
455 Racetrack Road, Washington, PA 15301 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Pittsburgh, Pennsylvania · Commercial and Institutional Building Construction · NAICS 236220
Since 1978, OSHA inspectors have visited Repal Construction Co., Inc. in Pennsylvania 44 times.
The most recent inspection opened on Jun 21, 2016 as a planned inspection, in Washington.
In all, OSHA issued 97 citation items: 57 serious, 2 repeat and 38 other-than-serious.
The proposed penalties came to $22,365; today they stand at $16,944, 24% less.
The rule cited most here is 1926.500 (scope, application, and definitions applicable to this subpart), 9 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Repal Construction Co., Inc. averages $0 across 1 cited inspection.
Pennsylvania · latest 90 days of OSHA records
285employers cited
4 of them in the same industry
Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Pennsylvania
Checking a subcontractor, a client or your own company? Watch Repal Construction Co., Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company455 Racetrack Road, Washington, PA 15301 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
4800 Penn Avenue, Pittsburgh, PA 15224 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.153(o) · Liquefied petroleum gas (LP-Gas) |
Other-than-serious | $0 | $0 | Mar 9, 2016 | Final |
| Citation 1, item 1b 29 CFR 1926.602(d) · Earthmovers and forklifts in construction |
Other-than-serious | $0 | $0 | Mar 9, 2016 | Final |
| Citation 1, item 2 29 CFR 1926.404(f)(6) · Ground-fault protection on job sites |
Other-than-serious | $0 | $0 | Mar 9, 2016 | Final |
420 Wood Street, Pittsburgh, PA 15222 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
6022 Glades Pike Suite 100, Somerset, PA 15501 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2021 James Street, Latrobe, PA 15650 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.417(b) · Lockout and tagging of circuits |
Serious | $1,000 | $700 | Jan 16, 2009 | Final |
Second East Hills Apartments, Pittsburgh, PA 15221 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Second East Hills Apartments, Pittsburgh, PA 15221 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Springfield Township Shopping Center, Huntingdon, PA 16652 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
640 California Avenue, Pittsburgh, PA 15202 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.1200(e)(4) · Hazard communication |
Other-than-serious | $0 | $0 | Nov 2, 2005 | Closed |
2021 Clay Pike Road, Irwin, PA 15642 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
400 Cornell Road, Blairsville, PA 15717 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
5290 Rt. 30 East, Greensburg, PA 15601 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2021 Clay Pike Road, Irwin, PA 15642 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.651(c)(2) · Excavations |
Serious | $900 | $630 | Jul 7, 2004 | Closed |
| Citation 1, item 2 29 CFR 1926.651(i)(1) · Excavations |
Serious | $2,100 | $1,470 | Jul 7, 2004 | Closed |
| Citation 1, item 3 29 CFR 1926.651(k)(1) · Excavations |
Serious | $900 | $630 | Jul 7, 2004 | Closed |
| Citation 1, item 4a 29 CFR 1926.652(a)(1) · Trench protection |
Serious | $2,100 | $1,470 | Jul 7, 2004 | Closed |
| Citation 1, item 4b 29 CFR 1926.652(b)(2) · Trench protection |
Serious | $0 | $0 | Jul 7, 2004 | Closed |
| Citation 1, item 5a 29 CFR 1926.703(a)(1) · Requirements for cast-in-place concrete |
Serious | $1,500 | $1,050 | Jul 7, 2004 | Closed |
| Citation 1, item 5b 29 CFR 1926.703(a)(2) · Requirements for cast-in-place concrete |
Serious | $0 | $0 | Jul 7, 2004 | Closed |
Foxburg Medical Center, Route 58, Foxburg, PA 16036 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Wal Mart Rt. 22, Blairsville, PA 15717 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 3 29 CFR 1926.652(a)(1) · Trench protection |
Serious | $1,000 | $750 | Nov 5, 2003 | Final |
Wal Mart Rt. 22, Blairsville, PA 15717 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Camp Allegheny, Ellwood City, PA 16117 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(13) · Fall protection in construction |
Serious | $375 | $244 | May 4, 1999 | Closed |
Rochester Manor & Villa, 174 Virginia Avenue, Rochester, PA 15074 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.20(b)(2) · Construction safety programs |
Serious | $165 | $165 | Aug 1, 1995 | Closed |
| Citation 1, item 1b 29 CFR 1926.95(a) · Criteria for personal protective equipment |
Serious | $0 | $0 | Aug 1, 1995 | Closed |
| Citation 1, item 1c 29 CFR 1926.405(a)(2)(iic) · Job-site wiring |
Serious | $0 | $0 | Aug 1, 1995 | Closed |
| Citation 1, item 1d 29 CFR 1926.405(a)(2)(iif) · Job-site wiring |
Serious | $0 | $0 | Aug 1, 1995 | Closed |
| Citation 1, item 2 29 CFR 1926.501(b)(14) · Fall protection in construction |
Serious | $165 | $165 | Aug 1, 1995 | Closed |
| Citation 2, item 1 29 CFR 1926.850(a) · Preparatory operations |
Other-than-serious | $0 | $0 | Aug 1, 1995 | Closed |
| Citation 2, item 2 29 CFR 1926.405(a)(2)(iib) · Job-site wiring |
Other-than-serious | $0 | $0 | Aug 1, 1995 | Closed |
| Citation 2, item 3 29 CFR 1926.350(a)(1) · Gas welding and cutting |
Other-than-serious | $0 | $0 | Aug 1, 1995 | Closed |
| Citation 2, item 4 29 CFR 1926.350(j) · Gas welding and cutting |
Other-than-serious | $0 | $0 | Aug 1, 1995 | Closed |
110 Fredonia Road, Greenville, PA 16125 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.403(i)(2)(i) · Electrical equipment on job sites |
Serious | $100 | $100 | Jul 12, 1995 | Closed |
| Citation 1, item 1b 29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites |
Serious | $0 | $0 | Jul 12, 1995 | Closed |
Otterman And Pennsylvania Streets, Greensburg, PA 15601 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.405(a)(2)(iij) · Job-site wiring |
Serious | $1,000 | $650 | Apr 30, 1992 | Closed |
| Citation 1, item 2 29 CFR 1926.651(i)(1) · Excavations |
Serious | $1,000 | $650 | Apr 30, 1992 | Closed |
| Citation 1, item 3 29 CFR 1926.651(l)(1) · Excavations |
Serious | $1,000 | $650 | Apr 30, 1992 | Closed |
| Citation 1, item 4 29 CFR 1926.651(l)(2) · Excavations |
Serious | $1,000 | $650 | Apr 30, 1992 | Closed |
| Citation 1, item 5 29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements |
Serious | $1,000 | $650 | Apr 30, 1992 | Closed |
Fayette Plaza, Route 51, Uniontown, PA 15401 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Clair Boyce Office Space, Upper St. Clair, PA 15228 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
240-250 Executive Drive, Mars, PA 16046 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.350(j) · Gas welding and cutting |
Serious | $300 | $300 | Jul 26, 1990 | Closed |
| Citation 2, item 1 29 CFR 1926.500(e)(1)(i) · Scope, application, and definitions applicable to this subpart |
Other-than-serious | $0 | $0 | Jul 26, 1990 | Closed |
Old Wm. Penn Highway, Dialysis Clinic, Monroeville, PA 15146 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.100(a) · Hard hats in construction |
Serious | $320 | $320 | Sep 5, 1989 | Closed |
| Citation 2, item 1 29 CFR 1926.20(b)(1) · Construction safety programs |
Repeat | $320 | $320 | Sep 5, 1989 | Closed |
| Citation 3, item 1 29 CFR 1903.2(a)(1) · Posting of notice; availability of the Act, regulations and applicable standards |
Other-than-serious | $0 | $0 | Sep 5, 1989 | Closed |
| Citation 3, item 2 29 CFR 1926.20(b)(2) · Construction safety programs |
Other-than-serious | $0 | $0 | Sep 5, 1989 | Closed |
| Citation 3, item 3 29 CFR 1926.50(f) · Medical services and first aid |
Other-than-serious | $0 | $0 | Sep 5, 1989 | Closed |
| Citation 3, item 4 29 CFR 1926.59(e)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Sep 5, 1989 | Closed |
| Citation 3, item 5 29 CFR 1926.59(h) · Hazard communication |
Other-than-serious | $0 | $0 | Sep 5, 1989 | Closed |
K-mart, Route 19 South, Cranberry Township, PA 16046 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(e)(10) · Scaffolds, general requirements |
Serious | $300 | $300 | Jul 26, 1989 | Closed |
| Citation 2, item 1 | Other-than-serious | $0 | $0 | Jul 26, 1989 | Closed |
| Citation 2, item 2 | Other-than-serious | $0 | $0 | Jul 26, 1989 | Closed |
| Citation 2, item 3 | Other-than-serious | $0 | $0 | Jul 26, 1989 | Closed |
| Citation 2, item 4 29 CFR 1926.59(e)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Jul 26, 1989 | Closed |
| Citation 2, item 5 29 CFR 1926.59(g)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Jul 26, 1989 | Closed |
| Citation 2, item 6 29 CFR 1926.59(h) · Hazard communication |
Other-than-serious | $0 | $0 | Jul 26, 1989 | Closed |
| Citation 2, item 7 29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites |
Other-than-serious | $0 | $0 | Jul 26, 1989 | Closed |
| Citation 2, item 8 29 CFR 1926.451(e)(4) · Scaffolds, general requirements |
Other-than-serious | $0 | $0 | Jul 26, 1989 | Closed |
| Citation 2, item 9 29 CFR 1926.451(e)(5) · Scaffolds, general requirements |
Other-than-serious | $0 | $0 | Jul 26, 1989 | Closed |
| Citation 2, item 10 29 CFR 1926.451(e)(8) · Scaffolds, general requirements |
Other-than-serious | $0 | $0 | Jul 26, 1989 | Closed |
Warehouse Building #503, I79 North Industrial Park, Sewickley, PA 15143 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.500(g)(1) · Scope, application, and definitions applicable to this subpart |
Serious | $560 | $560 | Dec 6, 1988 | Closed |
| Citation 1, item 1b 29 CFR 1926.500(g)(6)(i) · Scope, application, and definitions applicable to this subpart |
Serious | $0 | $0 | Dec 6, 1988 | Closed |
| Citation 2, item 1 29 CFR 1926.20(b)(1) · Construction safety programs |
Repeat | $160 | $160 | Dec 6, 1988 | Closed |
79 North Industrial Park, Aleppo Twp., PA 15143 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1401 Forbes Avenue, Pittsburgh, PA 15219 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites |
Serious | $480 | $480 | May 27, 1988 | Closed |
| Citation 1, item 1b 29 CFR 1926.20(b)(1) · Construction safety programs |
Serious | $0 | $0 | May 27, 1988 | Closed |
| Citation 1, item 1c 29 CFR 1926.20(b)(2) · Construction safety programs |
Serious | $0 | $0 | May 27, 1988 | Closed |
| Citation 1, item 1e 29 CFR 1926.21(b)(2) · Construction safety training |
Serious | $0 | $0 | May 27, 1988 | Closed |
| Citation 1, item 2 29 CFR 1926.405(a)(2)(iij) · Job-site wiring |
Serious | $400 | $400 | May 27, 1988 | Closed |
| Citation 2, item 1 29 CFR 1926.50(d)(1) · Medical services and first aid |
Other-than-serious | $0 | $0 | May 27, 1988 | Closed |
4700 Mcknight Road, Pittsburgh, PA 15237 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.25(a) · Housekeeping |
Serious | $480 | $300 | Apr 19, 1988 | Closed |
| Citation 1, item 1b 29 CFR 1926.25(b) · Housekeeping |
Serious | $0 | $0 | Apr 19, 1988 | Closed |
| Citation 1, item 2 29 CFR 1926.102(a)(1) · Eye and face protection in construction |
Serious | $480 | $300 | Apr 19, 1988 | Closed |
| Citation 1, item 3a 29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites |
Serious | $400 | $300 | Apr 19, 1988 | Closed |
| Citation 1, item 3b 29 CFR 1926.405(a)(2)(iij) · Job-site wiring |
Serious | $0 | $0 | Apr 19, 1988 | Closed |
| Citation 1, item 4 29 CFR 1926.405(b)(1) · Job-site wiring |
Serious | $400 | $300 | Apr 19, 1988 | Closed |
| Citation 1, item 5a 29 CFR 1926.500(d)(1) · Scope, application, and definitions applicable to this subpart |
Serious | $480 | $300 | Apr 19, 1988 | Closed |
| Citation 1, item 5b 29 CFR 1926.20(b)(1) · Construction safety programs |
Serious | $0 | $0 | Apr 19, 1988 | Closed |
| Citation 1, item 5c 29 CFR 1926.20(b)(2) · Construction safety programs |
Serious | $0 | $0 | Apr 19, 1988 | Closed |
| Citation 1, item 5d 29 CFR 1926.21(b)(2) · Construction safety training |
Serious | $0 | $0 | Apr 19, 1988 | Closed |
| Citation 2, item 1 29 CFR 1904.2(b)(2) · Partial exemption for establishments in certain industries |
Other-than-serious | $0 | $0 | Apr 19, 1988 | Closed |
| Citation 2, item 2 29 CFR 1926.350(a)(9) · Gas welding and cutting |
Other-than-serious | $0 | $0 | Apr 19, 1988 | Closed |
| Citation 2, item 3 29 CFR 1926.500(c)(1)(iv) · Scope, application, and definitions applicable to this subpart |
Other-than-serious | $0 | $0 | Apr 19, 1988 | Closed |
4700 Mcknight Road, Pittsburgh, PA 15237 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
4700 Mcknight Road, Pittsburgh, PA 15237 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1026 Fifth Avenue, Pittsburgh, PA 15222 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.401(a)(1) · [Reserved] |
Serious | $240 | $240 | Dec 4, 1985 | Closed |
| Citation 1, item 1b 29 CFR 1926.400(h)(1) · Introduction |
Serious | $0 | $0 | Dec 4, 1985 | Closed |
| Citation 1, item 2 29 CFR 1926.500(b)(1) · Scope, application, and definitions applicable to this subpart |
Serious | $180 | $180 | Dec 3, 1985 | Closed |
| Citation 1, item 3 29 CFR 1926.56(a) · Illumination |
Serious | $240 | $240 | Dec 4, 1985 | Closed |
245 North Craig Street, Pittsburgh, PA 15213 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
R.d. L, Mcdonald, PA 15057 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Freeport Road O'hara Township, Pittsburgh, PA 15238 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1000 California Ave, Pittsburgh, PA 15212 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
5541 Walnut St Shadyside, Pittsburgh, PA 15206 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.450(a)(10) · Scope, application and definitions applicable to this subpart |
Serious | $150 | $150 | Nov 9, 1983 | Closed |
| Citation 1, item 1b 29 CFR 1926.450(a)(9) · Scope, application and definitions applicable to this subpart |
Serious | $0 | $0 | Nov 9, 1983 | Closed |
| Citation 1, item 2 29 CFR 1926.451(d)(10) · Scaffolds, general requirements |
Serious | $200 | $200 | Nov 9, 1983 | Closed |
| Citation 1, item 3 29 CFR 1926.500(c)(1) · Scope, application, and definitions applicable to this subpart |
Serious | $200 | $200 | Nov 9, 1983 | Closed |
| Citation 1, item 4 29 CFR 1926.500(e)(1)(ii) · Scope, application, and definitions applicable to this subpart |
Serious | $150 | $150 | Nov 9, 1983 | Closed |
| Citation 1, item 5 29 CFR 1926.501(f) · Fall protection in construction |
Serious | $200 | $200 | Nov 9, 1983 | Closed |
| Citation 1, item 6 29 CFR 1926.500(d)(1) · Scope, application, and definitions applicable to this subpart |
Serious | $200 | $200 | Nov 9, 1983 | Closed |
| Citation 2, item 1 29 CFR 1926.350(a)(9) · Gas welding and cutting |
Other-than-serious | $0 | $0 | Nov 9, 1983 | Closed |
United Plate Glass Bldg Anders, Pittsburgh, PA 15233 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.401(f) · [Reserved] |
Serious | $50 | $50 | Jun 24, 1983 | Closed |
| Citation 1, item 1b 29 CFR 1926.400(h)(1) · Introduction |
Serious | $0 | $0 | Jun 24, 1983 | Closed |
| Citation 1, item 2 29 CFR 1926.451(a)(13) · Scaffolds, general requirements |
Serious | $50 | $50 | Jun 24, 1983 | Closed |
| Citation 2, item 1 29 CFR 1926.21(b)(2) · Construction safety training |
Other-than-serious | $0 | $0 | Jun 24, 1983 | Closed |
| Citation 2, item 2 29 CFR 1926.302(b)(7) · Power-operated hand tools |
Other-than-serious | $0 | $0 | Jun 24, 1983 | Closed |
Pitt Bldg 3rd Smithfield St, Pittsburgh, PA 15220 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.50(f) · Medical services and first aid |
Other-than-serious | $0 | $0 | Sep 29, 1982 | Closed |
| Citation 1, item 2 29 CFR 1926.402(a)(5) · Applicability |
Other-than-serious | $0 | $0 | Sep 29, 1982 | Closed |
Medical Professional Bldg Linc, Mckeesport, PA 15132 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.650(e) · Scope, application, and definitions applicable to this subpart |
Serious | $120 | $120 | Sep 1, 1982 | Closed |
| Citation 2, item 1 29 CFR 1903.2(a)(1) · Posting of notice; availability of the Act, regulations and applicable standards |
Other-than-serious | $0 | $0 | Sep 1, 1982 | Closed |
| Citation 2, item 2 29 CFR 1926.300(b)(2) · Tools—Hand and Power: general requirements |
Other-than-serious | $0 | $0 | Sep 1, 1982 | Closed |
Nesbit Building 718 Fifth Aven, Pittsburgh, PA 15219 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1016 Greentree Road, Green Tree, PA 15205 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Walnut Commons Aspen 1300 1312, Wilkinsburg, PA 15221 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1903.2(a)(1) · Posting of notice; availability of the Act, regulations and applicable standards |
Other-than-serious | $0 | $0 | Oct 24, 1979 | Closed |
| Citation 1, item 2 29 CFR 1926.50(f) · Medical services and first aid |
Other-than-serious | $0 | $0 | Oct 24, 1979 | Closed |
| Citation 1, item 3 29 CFR 1926.400(h)(1) · Introduction |
Other-than-serious | $0 | $0 | Oct 24, 1979 | Closed |
Saniel Dr, West Mifflin, PA 15122 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1903.2(a)(1)
(a)(1) Each employer shall post and keep posted a notice or notices, to be furnished by the Occupational Safety and Health Administration, U.S. Department of Labor, informing employees of the protections and obligations provided for in the Act, and that for assistance and information, including copies of the Act and of specific safety and health standards, employees should contact the employer or the nearest office of the Department of Labor. Such notice or notices shall be posted by the employer in each establishment in a conspicuous place or places where notices to employees are customarily posted. Each employer shall take steps to insure that such notices are not altered, defaced, or covered by other material.
29 CFR 1904.2(b)(2)
(2) How do I determine the correct NAICS code for my company or for individual establishments? You can determine your NAICS code by using one of three methods, or you may contact your nearest OSHA office or State agency for help in determining your NAICS code:
29 CFR 1910.1200(e)(4)
(4) The employer shall make the written hazard communication program available, upon request, to employees, their designated representatives, the Assistant Secretary and the Director, in accordance with the requirements of § 1910.1020(e).
Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.