OSHA SearchOSHA records by employer

Rhoads Metal Works, Inc.: OSHA inspections and violations

Pennsauken, New Jersey · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · NAICS 333415

2inspections
7citation items
$9,952current penalties
Jun 26, 2019last inspection

Rhoads Metal Works, Inc. has 2 OSHA inspections on record in New Jersey, the first in 2010.

OSHA's last visit started on Jun 26, 2019 as a planned inspection, in Pennsauken.

Across those inspections OSHA issued 7 citation items: 7 serious.

OSHA proposed $15,108 in penalties. After settlements and reviews the total is $9,952, down 34%.

Most often, OSHA cited 1910.134, respiratory protection (2 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Rhoads Metal Works, Inc. averages $6,577 over 1 cited inspection in that time.

Rhoads Metal Works, Inc.: OSHA citation items per year, 2010 to 2019
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

274employers cited

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch Rhoads Metal Works, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344109897 OPENED JUN 26, 2019Closed

Planned · Complete · Health · 39 employees at the site · Closed May 11, 2022

1551 John Tipton Blvd., Pennsauken, NJ 08110 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Serious$3,978$2,466Oct 23, 2019Final
Citation 1, item 1b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Oct 23, 2019Final
Citation 1, item 2
29 CFR 1910.1026(d)(1) · Hexavalent chromium
Serious$6,630$4,111Oct 23, 2019Final

Inspection 314672577 OPENED JUL 6, 2010Closed

Planned · Complete · Safety · 31 employees at the site · Closed Sep 29, 2010

1551 John Tipton Blvd., Pennsauken, NJ 08110 · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$1,250$938Aug 3, 2010Closed
Citation 1, item 2
29 CFR 1910.178(l) · Forklifts and other powered industrial trucks
Serious$1,250$938Aug 3, 2010Closed
Citation 1, item 3
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$1,250$938Aug 3, 2010Closed
Citation 1, item 4
29 CFR 1910.252(b)(2)(iii) · Welding fire safety
Serious$750$562Aug 3, 2010Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1026 · Hexavalent chromium

29 CFR 1910.1026(d)(1)

(d) Exposure determination—(1) General. Each employer who has a workplace or work operation covered by this section shall determine the 8-hour TWA exposure for each employee exposed to chromium (VI). This determination shall be made in accordance with either paragraph (d)(2) or paragraph (d)(3) of this section.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(2)(ii)

(ii) In addition, the employer must establish and implement those elements of a written respiratory protection program necessary to ensure that any employee using a respirator voluntarily is medically able to use that respirator, and that the respirator is cleaned, stored, and maintained so that its use does not present a health hazard to the user. Exception: Employers are not required to include in a written respiratory protection program those employees whose only use of respirators involves the voluntary use of filtering facepieces (dust masks).

29 CFR 1910.134(e)(1)

(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.252 · Welding fire safety

OSH Act Section 5 · General Duty Clause

Other air-conditioning and warm air heating equipment and commercial and industrial refrigeration equipment manufacturing employers in New Jersey

Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.