Robinson Concrete Inc: OSHA inspections and violations
Auburn, New York · Ready-Mix Concrete Manufacturing · NAICS 327320
5inspections
14citation items
$5,210current penalties
May 13, 2016last inspection
OSHA has inspected Robinson Concrete Inc 5 times in New York since 1979.
The latest one began on May 13, 2016 as a planned inspection, in Auburn.
Those inspections ended with 14 citation items: 9 serious and 5 other-than-serious.
Penalties were first proposed at $12,490 and now stand at $5,210, 58% lower after settlements or reviews.
Respiratory protection comes up most often in these citations: 4 items under 1910.134.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Robinson Concrete Inc averages $0 (1 cited inspection).
Robinson Concrete Inc also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
New York · latest 90 days of OSHA records
362employers cited
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious
$0
$0
Dec 26, 1979
Closed
Injury and illness logs
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Auburn site logged 2 recordable injuries or illnesses among about 30 workers: 5.4 per 100 full-time workers, against a median of 3.4 for its industry. Those cases cost 64 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Robinson Concrete Inc.
Auburn · 2025
30
2
1
5.4
3.4
Auburn Ready Mix Facility
Auburn · 2017
95
1
1
0.9
3.4
Auburn Ready Mix Facility, Custom Concrete Pumping, Robinson Roll Off, Red Creek Ready Mix Facility
Auburn · 2016
106
5
4
4.0
3.4
Included with any plan: 5 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(2) Minimum separation. There shall be no open flame or spark producing equipment in any spraying area nor within 20 feet thereof, unless separated by a partition.
29 CFR 1910.107(c)(6)
(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.
29 CFR 1910.107(g)(2)
(2) Cleaning. All spraying areas shall be kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary. Scrapers, spuds, or other such tools used for cleaning purposes shall be of nonsparking material.
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.