OSHA SearchOSHA records by employer

Rock Energy Cooperative: OSHA inspections and violations

Janesville, Wisconsin · Electric Power Distribution · NAICS 221122

1inspections
1citation items
$16,550current penalties
Oct 19, 2024last inspection

OSHA inspectors have visited Rock Energy Cooperative in Wisconsin one time.

It opened on Oct 19, 2024 after a fatality or catastrophe, in Janesville.

In all, OSHA issued 1 citation item: 1 serious.

The penalties, $16,550 in total, stand where OSHA first set them.

Among utility employers, the typical cited inspection since 2015 ends with a $0 penalty. Rock Energy Cooperative averages $16,550 across 1 cited inspection.

1 inspection on this page followed a fatal incident.

Rock Energy Cooperative also files yearly injury logs with OSHA, summarized below.

Rock Energy Cooperative: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

218employers cited

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch Rock Energy Cooperative and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347827354 OPENED OCT 19, 2024Closed

Fatality or catastrophe · Partial · Safety · 22 employees at the site · Closed Feb 21, 2025

Rock County Fairgrounds 1301 Craig Avenue, Janesville, WI 53545 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps

Incident on Oct 19, 2024 (fatal): Employee dies of blunt trauma in fall from bucket truck boom

At 10:45 a.m. on October 19, 2024, an employee working for an electric power distribution company was giving rides to attendees of a customer appreciation event . The employee was operating a the bucket of an International Electrical Bucket Truck equipped with a Versalift telescoping aerial lift. The employee was descending within the insulated bucket of aerial lift when the bucket unexpectedly tipped downward. This caused the plastic, insulated dielectric lining to slide out of the bucket dropping the employee to the ground. The employee fell approximately 10 feet and impacted the ground below. The employee died from blunt force trauma to head, torso and extremities.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.67(c)(2)(v) · Vehicle-mounted elevating and rotating work platforms
Serious$16,550$16,550Jan 31, 2025Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Janesville site logged 1 recordable injury or illness among about 23 workers: 5.4 per 100 full-time workers, against a median of 1.0 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Janesville Headquarters
Janesville · 2025
23 105.41.0

Included with any plan: 4 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.67 · Vehicle-mounted elevating and rotating work platforms

29 CFR 1910.67(c)(2)(v)

(v) A personal fall arrest or travel restraint system that meets the requirements in subpart I of this part shall be worn and attached to the boom or basket when working from an aerial lift.

Other electric power distribution employers in Wisconsin

Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.