OSHA SearchOSHA records by employer

Schillinger, Inc.: OSHA inspections and violations

Curtis Bay, Maryland · Electroplating, Plating, Polishing, Anodizing, and Coloring · NAICS 332813

2inspections
13citation items
$1,800current penalties
Oct 5, 2022last inspection

OSHA has inspected Schillinger, Inc. 2 times in Maryland since 2022.

The latest one began on Oct 5, 2022 as a planned inspection, in Curtis Bay.

Those inspections ended with 13 citation items: 3 serious and 10 other-than-serious.

Penalties were first proposed at $1,800 and still stand at $1,800.

Electrical wiring methods comes up most often in these citations: 4 items under 1910.305.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Schillinger, Inc. averages $900 (2 cited inspections).

Schillinger, Inc.: OSHA citation items per year, 2022 to 2022
Citation items per year, by inspection date.

Want to know if OSHA cites Schillinger, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 346263908 OPENED OCT 5, 2022Closed

Planned · Complete · Safety · 10 employees at the site · Closed Feb 2, 2023

7615 Energy Parkway, Curtis Bay, MD 21226 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$750$750Jan 13, 2023Final
Citation 1, item 2
29 CFR 1910.305(j)(1)(i) · Electrical wiring methods
Serious$900$900Jan 13, 2023Final
Citation 2, item 1
29 CFR 1910.28(b)(1)(i) · Fall protection in general industry
Other-than-serious$0$0Jan 13, 2023Final
Citation 2, item 2
29 CFR 1910.29(b)(2)(i) · Fall protection systems in general industry
Other-than-serious$0$0Jan 13, 2023Final
Citation 2, item 3
29 CFR 1910.178(a)(6) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Jan 13, 2023Final
Citation 2, item 4
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Jan 13, 2023Final
Citation 2, item 5
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Other-than-serious$0$0Jan 13, 2023Final
Citation 2, item 6
29 CFR 1910.305(c)(4) · Electrical wiring methods
Other-than-serious$0$0Jan 13, 2023Final
Citation 2, item 7
29 CFR 1910.305(e)(1) · Electrical wiring methods
Other-than-serious$0$0Jan 13, 2023Final
Citation 2, item 8
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Other-than-serious$0$0Jan 13, 2023Final

Inspection 346265044 OPENED OCT 5, 2022Closed

Planned · Complete · Health · 10 employees at the site · Closed Feb 21, 2023

7615 Energy Parkway, Curtis Bay, MD 21226 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1200(g)(1) · Hazard communication
Serious$150$150Jan 31, 2023Final
Citation 2, item 1
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Jan 31, 2023Final
Citation 2, item 2
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$0$0Jan 31, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(g)(1)

(g) Safety data sheets. (1) Chemical manufacturers and importers shall obtain or develop a safety data sheet for each hazardous chemical they produce or import. Employers shall have a safety data sheet in the workplace for each hazardous chemical which they use.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.132(d)(2)

(2) The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(2)(i)

(i) An employer may provide respirators at the request of employees or permit employees to use their own respirators, if the employer determines that such respirator use will not in itself create a hazard. If the employer determines that any voluntary respirator use is permissible, the employer shall provide the respirator users with the information contained in appendix D to this section (“Information for Employees Using Respirators When Not Required Under the Standard”); and

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.28 · Fall protection in general industry

29 CFR 1910.29 · Fall protection systems in general industry

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

Other electroplating, plating, polishing, anodizing, and coloring employers in Maryland