Scott Builders, LLC: OSHA inspections and violations

Scituate, Rhode Island · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

1inspections
8citation items
$4,800current penalties
Sep 3, 2015last inspection

Scott Builders, LLC has one OSHA inspection on record in Rhode Island.

OSHA opened it on Sep 3, 2015 on a referral, in Scituate.

From that inspection OSHA issued 8 citation items: 7 serious and 1 other-than-serious.

OSHA proposed $9,600 in penalties. After settlements and reviews the total is $4,800, down 50%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Scott Builders, LLC averages $4,800 over 1 cited inspection in that time.

Scott Builders, LLC: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Want to know if OSHA cites Scott Builders, LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 340894906 OPENED SEP 3, 2015Closed

Referral · Partial · Safety · 4 employees at the site · Closed Sep 21, 2016

16 Institute Lane, Scituate, RI 02857 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$2,800$1,400Feb 17, 2016Final
Citation 1, item 2
29 CFR 1926.100(a) · Hard hats in construction
Serious$2,000$1,000Feb 17, 2016Final
Citation 1, item 3a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$2,000$1,000Feb 17, 2016Final
Citation 1, item 3b
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$0$0Feb 17, 2016Final
Citation 1, item 3c
29 CFR 1926.452(g)(1) · Rules for each type of scaffold
Serious$0$0Feb 17, 2016Final
Citation 1, item 4a
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$2,800$1,400Feb 17, 2016Final
Citation 1, item 4b
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$0$0Feb 17, 2016Final
Citation 2, item 1
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Feb 17, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(l)(4)(iii)

(iii) An evaluation of each powered industrial truck operator's performance shall be conducted at least once every three years.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.501 · Fall protection in construction

OSH Act Section 5 · General Duty Clause

Other new single-family housing construction (except for-sale builders) employers in Rhode Island