OSHA SearchOSHA records by employer

Seconn Fabrication: OSHA inspections and violations

Waterford, Connecticut · Sheet Metal Work Manufacturing · NAICS 332322

4inspections
27citation items
$23,503current penalties
Feb 19, 2019last inspection

Seconn Fabrication has 4 OSHA inspections on record in Connecticut, the first in 2010.

OSHA's last visit started on Feb 19, 2019 as a planned inspection, in Waterford.

Across those inspections OSHA issued 27 citation items: 24 serious and 3 other-than-serious.

OSHA proposed $39,850 in penalties. After settlements and reviews the total is $23,503, down 41%.

Most often, OSHA cited 1910.107, spray painting and finishing (8 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Seconn Fabrication averages $5,522 over 1 cited inspection in that time.

Seconn Fabrication also files yearly injury logs with OSHA, summarized below.

Seconn Fabrication: OSHA citation items per year, 2010 to 2019
Citation items per year, by inspection date.

Connecticut · latest 90 days of OSHA records

86employers cited

Get notified the morning OSHA posts each new citation in Connecticut: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Connecticut

Checking a subcontractor, a client or your own company? Watch Seconn Fabrication and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343793550 OPENED FEB 19, 2019Closed

Planned · Partial · Safety · 55 employees at the site · Closed Mar 1, 2019

180 Cross Road, Waterford, CT 06385 · Sheet Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$4,508$3,156Feb 22, 2019Final
Citation 1, item 2
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$3,381$2,367Feb 22, 2019Final

Inspection 316008275 OPENED MAR 15, 2012Closed

Planned · Partial · Health · 40 employees at the site · Closed Jun 3, 2013

180 Cross Road, Waterford, CT 06385 · Sheet Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1b
29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing
Serious$0$2,000Jun 6, 2012Final
Citation 1, item 1c
29 CFR 1910.107(b)(10) · Spray painting and finishing
Serious$0$0Jun 6, 2012Final
Citation 1, item 2a
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$4,000$2,000Jun 6, 2012Final
Citation 1, item 2c
29 CFR 1910.107(i)(8) · Spray painting and finishing
Serious$0$0Jun 6, 2012Final
Citation 1, item 2d
29 CFR 1910.107(l)(2)(ii) · Spray painting and finishing
Serious$0$0Jun 6, 2012Final
Citation 1, item 3a
29 CFR 1910.107(l)(4)(i) · Spray painting and finishing
Serious$2,400$1,200Jun 6, 2012Final
Citation 1, item 3b
29 CFR 1910.107(l)(4)(ii) · Spray painting and finishing
Serious$0$0Jun 6, 2012Final
Citation 1, item 3c
29 CFR 1910.107(l)(4)(iii) · Spray painting and finishing
Serious$0$0Jun 6, 2012Final
Citation 1, item 3d
29 CFR 1910.242(b) · Hand and power tools
Serious$0$0Jun 6, 2012Final
Citation 1, item 4c
29 CFR 1910.134(a)(2) · Respiratory protection
Other-than-serious$0$0Jun 6, 2012Final

Inspection 314405952 OPENED SEP 28, 2011Closed

Complaint · Partial · Safety · 40 employees at the site · Closed Jul 27, 2013

180 Cross Road, Waterford, CT 06385 · Sheet Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$3,850$1,925Mar 21, 2012Final
Citation 1, item 2a
29 CFR 1910.22(a)(1) · General requirements
Serious$1,963$982Mar 21, 2012Final
Citation 1, item 2b
29 CFR 1910.305(g)(1)(iv) · Electrical wiring methods
Serious$0$0Mar 21, 2012Final
Citation 1, item 3a
29 CFR 1910.37(a)(3) · Exit routes
Serious$2,618$1,309Mar 21, 2012Final
Citation 1, item 3b
29 CFR 1910.38(b) · Emergency action plans
Serious$0$0Mar 21, 2012Final
Citation 1, item 3c
29 CFR 1910.157(g)(3) · Portable fire extinguishers
Serious$0$0Mar 21, 2012Final
Citation 1, item 4a
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Serious$3,080$1,540Mar 21, 2012Final
Citation 1, item 4b
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$0$0Mar 21, 2012Final
Citation 1, item 4c
29 CFR 1910.151(c) · First aid and eyewash
Serious$0$0Mar 21, 2012Final
Citation 1, item 5
29 CFR 1910.212(a)(1) · Machine guarding
Serious$3,850$1,925Mar 21, 2012Final
Citation 1, item 6
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$5,390$2,695Mar 21, 2012Final
Citation 1, item 7
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$2,310$1,155Mar 21, 2012Final
Citation 2, item 1
29 CFR 1910.37(b)(4) · Exit routes
Other-than-serious$0$0Mar 21, 2012Final
Citation 2, item 2
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Other-than-serious$0$0Mar 21, 2012Final

Inspection 314399650 OPENED JUL 2, 2010Closed

Planned · Partial · Safety · 5 employees at the site · Closed Oct 26, 2010

180 Cross Road, Waterford, CT 06385 · Sheet Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$2,500$1,250Jul 20, 2010Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Waterford site logged 0 recordable injuries or illnesses among about 36 workers: 0.0 per 100 full-time workers, against a median of 3.6 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Seconn Fabrication
Waterford · 2025
36 000.03.6
Seconn Fabrication LLC
Waterford · 2019
62 101.73.6

Included with any plan: 3 more yearly logs from these sites, back to 2018, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(10)

(10) Illumination. When spraying areas are illuminated through glass panels or other transparent materials, only fixed lighting units shall be used as a source of illumination. Panels shall effectively isolate the spraying area from the area in which the lighting unit is located, and shall be of a noncombustible material of such a nature or so protected that breakage will be unlikely. Panels shall be so arranged that normal accumulations of residue on the exposed surface of the panel will not be raised to a dangerous temperature by radiation or conduction from the source of illumination.

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(b)(5)(iv)

(iv) Space within the spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.22 · General requirements

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes

29 CFR 1910.38 · Emergency action plans

OSH Act Section 5 · General Duty Clause

Other sheet metal work manufacturing employers in Connecticut

Alert subscribers get notified of each newly cited employer in Connecticut the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.