OSHA SearchOSHA records by employer

Serampore Industries: OSHA inspections and violations

Houston, Texas · Metal Service Centers and Other Metal Merchant Wholesalers · NAICS 423510

2inspections
14citation items
$48,277current penalties
Jan 10, 2019last inspection

OSHA has inspected Serampore Industries 2 times in Texas since 2019.

The latest one began on Jan 10, 2019 on a referral, in Houston.

Those inspections ended with 14 citation items: 11 serious and 3 other-than-serious.

Penalties were first proposed at $80,466 and now stand at $48,277, 40% lower after settlements or reviews.

Electrical wiring methods comes up most often in these citations: 3 items under 1910.305.

How that compares: the median penalty per cited inspection for wholesale employers since 2015 is $3,425, and Serampore Industries averages $24,138 (2 cited inspections).

Serampore Industries: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

393employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Serampore Industries and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343703898 OPENED JAN 10, 2019Closed

Referral · Partial · Health · 22 employees at the site · Closed Apr 11, 2024

2900 Patio Drive, Houston, TX 77017 · Metal Service Centers and Other Metal Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$9,282$5,569May 1, 2019Final
Citation 1, item 2
29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing
Serious$9,282$5,569May 1, 2019Final
Citation 1, item 3
29 CFR 1910.107(d)(3) · Spray painting and finishing
Serious$7,956$4,773May 1, 2019Final
Citation 1, item 4
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$7,956$4,773May 1, 2019Final
Citation 1, item 5
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$7,956$4,773May 1, 2019Final
Citation 1, item 6
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$7,956$4,773May 1, 2019Final
Citation 1, item 7a
29 CFR 1910.307(b) · Hazardous (classified) locations
Serious$9,282$5,569May 1, 2019Final
Citation 1, item 7b
29 CFR 1910.307(c) · Hazardous (classified) locations
Serious$0$0May 1, 2019Final

Inspection 343697843 OPENED JAN 8, 2019Closed

Planned · Complete · Safety · 25 employees at the site · Closed Apr 12, 2019

2900 Patio Drive, Houston, TX 77017 · Metal Service Centers and Other Metal Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$9,282$5,569Mar 13, 2019Final
Citation 1, item 1b
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$0$0Mar 13, 2019Final
Citation 1, item 2
29 CFR 1910.305(d)(2) · Electrical wiring methods
Serious$9,282$5,569Mar 13, 2019Final
Citation 2, item 1
29 CFR 1910.176(a) · Material storage and aisles
Other-than-serious$744$446Mar 13, 2019Final
Citation 2, item 2
29 CFR 1910.178(l)(1)(ii) · Forklifts and other powered industrial trucks
Other-than-serious$744$446Mar 13, 2019Final
Citation 2, item 3
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Other-than-serious$744$446Mar 13, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(b)(5)(iv)

(iv) Space within the spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers.

29 CFR 1910.107(d)(3)

(3) Independent exhaust. Each spray booth shall have an independent exhaust duct system discharging to the exterior of the building, except that multiple cabinet spray booths in which identical spray finishing material is used with a combined frontal area of not more than 18 square feet may have a common exhaust. If more than one fan serves one booth, all fans shall be so interconnected that one fan cannot operate without all fans being operated.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.176 · Material storage and aisles

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.307 · Hazardous (classified) locations

Other metal service centers and other metal merchant wholesalers employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.