OSHA SearchOSHA records by employer

Sherman Roto Tank, LLC: OSHA inspections and violations

Pearland, Texas · All Other Miscellaneous Fabricated Metal Product Manufacturing · NAICS 332999

3inspections
20citation items
$33,655current penalties
Jun 24, 2024last inspection

Sherman Roto Tank, LLC has 3 OSHA inspections on record in Texas, the first in 2022.

OSHA's last visit started on Jun 24, 2024 on a referral, in Pearland.

Across those inspections OSHA issued 20 citation items: 20 serious.

OSHA proposed $87,996 in penalties. After settlements and reviews the total is $33,655, down 62%.

Most often, OSHA cited 1910.215, grinders and abrasive wheels (3 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Sherman Roto Tank, LLC averages $11,218 over 3 cited inspections in that time.

It reported 1 severe injury to OSHA since 2015.

Sherman Roto Tank, LLC: OSHA citation items per year, 2022 to 2024
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

399employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Sherman Roto Tank, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347571879 OPENED JUN 24, 2024Closed

Referral · Partial · Safety · 30 employees at the site · Closed Jul 21, 2025

8521 Industrial Drive, Pearland, TX 77584 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$12,421$6,200Dec 13, 2024Final

Inspection 346121080 OPENED AUG 3, 2022Closed

Referral · Partial · Health · 26 employees at the site · Closed Aug 4, 2026

8521 Industrial Drive, Pearland, TX 77584 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(b)(9) · Spray painting and finishing
Serious$5,801$3,481Jan 9, 2023Final
Citation 1, item 1b
29 CFR 1910.107(b)(10) · Spray painting and finishing
Serious$5,801$0Jan 9, 2023Final
Citation 1, item 1c
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$814$0Jan 9, 2023Final
Citation 1, item 3a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$5,801$3,480Jan 9, 2023Final
Citation 1, item 3b
29 CFR 1910.1200(g)(8) · Hazard communication
Serious$0$0Jan 9, 2023Final
Citation 1, item 3c
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Jan 9, 2023Final

Inspection 346088297 OPENED JUL 19, 2022Closed

Complaint · Complete · Safety · 26 employees at the site · Closed Feb 10, 2023

8521 Industrial Drive, Pearland, TX 77584 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1910.147(d)(4)(i) · Lockout/tagout
Serious$5,801$3,481Dec 22, 2022Final
Citation 1, item 3
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Serious$3,698$2,219Dec 22, 2022Final
Citation 1, item 6a
29 CFR 1910.215(a)(1) · Grinders and abrasive wheels
Serious$5,801$3,481Dec 22, 2022Final
Citation 1, item 6b
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$0$0Dec 22, 2022Final
Citation 1, item 6c
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Dec 22, 2022Final
Citation 1, item 7
29 CFR 1910.252(b)(2)(iii) · Welding fire safety
Serious$4,351$2,611Dec 22, 2022Final
Citation 1, item 8a
29 CFR 1910.303(b)(7)(i) · Electrical equipment, general requirements
Serious$4,351$2,611Dec 22, 2022Final
Citation 1, item 8b
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Serious$0$0Dec 22, 2022Final
Citation 5, item 1a
29 CFR 1910.179(n)(3)(v) · Overhead and gantry cranes
Serious$10,151$6,091Dec 22, 2022Final
Citation 5, item 1b
29 CFR 1910.28(b)(1)(i) · Fall protection in general industry
Serious$5,801$0Dec 22, 2022Final
Citation 5, item 1c
29 CFR 1910.178(m)(3) · Forklifts and other powered industrial trucks
Serious$8,702$0Dec 22, 2022Final
Citation 8, item 1c
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Serious$4,351$0Dec 22, 2022Final
Citation 8, item 1d
29 CFR 1910.334(a)(3)(i) · Using electrical equipment
Serious$4,351$0Dec 22, 2022Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Jun 18, 2024, Pearland: Amputation · amputations, avulsions, enucleations unspecified · other finger(s) n.e.c.

An employee was using a band saw to cut rectangular metal tubing. He went to move a piece of metal out of the way and the blade caused an amputation to his left little finger.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(10)

(10) Illumination. When spraying areas are illuminated through glass panels or other transparent materials, only fixed lighting units shall be used as a source of illumination. Panels shall effectively isolate the spraying area from the area in which the lighting unit is located, and shall be of a noncombustible material of such a nature or so protected that breakage will be unlikely. Panels shall be so arranged that normal accumulations of residue on the exposed surface of the panel will not be raised to a dangerous temperature by radiation or conduction from the source of illumination.

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(b)(9)

(9) Cleaning. Spray booths shall be so installed that all portions are readily accessible for cleaning. A clear space of not less than 3 feet on all sides shall be kept free from storage or combustible construction.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.28 · Fall protection in general industry

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.334 · Using electrical equipment

Other all other miscellaneous fabricated metal product manufacturing employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.