OSHA SearchOSHA records by employer

Silver Star Industries Inc: OSHA inspections and violations

Brainerd, Minnesota · Ornamental and Architectural Metal Work Manufacturing · NAICS 332323

5inspections
18citation items
$2,187current penalties
Feb 17, 2015last inspection

Since 1998, OSHA inspectors have visited Silver Star Industries Inc in Minnesota 5 times.

The most recent inspection opened on Feb 17, 2015 as a planned inspection, in Brainerd.

In all, OSHA issued 18 citation items: 14 serious and 4 other-than-serious.

The proposed penalties came to $2,875; today they stand at $2,187, 24% less.

The rule cited most here is 1910.305 (electrical wiring methods), 3 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Silver Star Industries Inc averages $400 across 1 cited inspection.

Silver Star Industries Inc: OSHA citation items per year, 1998 to 2015
Citation items per year, by inspection date.

Minnesota · latest 90 days of OSHA records

369employers cited

Get notified the morning OSHA posts each new citation in Minnesota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Minnesota

Checking a subcontractor, a client or your own company? Watch Silver Star Industries Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 317963254 OPENED FEB 17, 2015Closed

Planned · Complete · Health · 15 employees at the site · Closed Jun 22, 2015

3231 Oak Street, Brainerd, MN 56401 · Farm Machinery and Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(a)(2) · Respiratory protection
Other-than-serious$600$400Feb 25, 2015Final

Inspection 315954131 OPENED SEP 8, 2011Closed

Planned · Complete · Safety · 16 employees at the site · Closed Oct 21, 2011

3231 Oak Street, Brainerd, MN 56401 · Ornamental and Architectural Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$350$245Sep 29, 2011Closed
Citation 1, item 2
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$150$105Sep 29, 2011Closed
Citation 2, item 1 Other-than-serious$100$70Sep 29, 2011Closed

Inspection 304609894 OPENED SEP 12, 2001Closed

Planned · Complete · Health · 20 employees at the site · Closed Jan 31, 2002

1345 Hwy 18 E, Brainerd, MN 56401 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$400$280Oct 18, 2001Closed
Citation 2, item 1
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$0$0Oct 18, 2001Closed

Inspection 303472526 OPENED MAY 1, 2000Closed

Planned · Complete · Safety · 14 employees at the site · Closed Jun 21, 2000

1345 Hwy 18 E, Brainerd, MN 56401 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.217(c)(1)(i) · Mechanical power presses
Serious$125$87May 30, 2000Closed
Citation 1, item 2
29 CFR 1910.217(d)(9)(ii) · Mechanical power presses
Serious$100$70May 30, 2000Closed
Citation 1, item 3
29 CFR 1910.242(b) · Hand and power tools
Serious$100$70May 30, 2000Closed
Citation 1, item 4
29 CFR 1910.254(d)(9)(iii) · Arc welding and cutting
Serious$100$70May 30, 2000Closed
Citation 1, item 5
29 CFR 1910.305(a)(1)(i) · Electrical wiring methods
Serious$100$70May 30, 2000Closed
Citation 2, item 1
29 CFR 1910.107(b)(10) · Spray painting and finishing
Other-than-serious$100$70May 30, 2000Closed

Inspection 302088802 OPENED APR 20, 1998Closed

Complaint · Partial · Health · 18 employees at the site · Closed May 4, 1999

1345 Hwy 18 E, Brainerd, MN 56401 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.151(c) · First aid and eyewash
Serious$100$100Jun 2, 1998Closed
Citation 1, item 2
29 CFR 1910.254(d)(9)(iii) · Arc welding and cutting
Serious$150$150Jun 2, 1998Closed
Citation 1, item 3a
29 CFR 1910.1000(a)(2) · Air contaminants
Serious$250$250Jun 2, 1998Closed
Citation 1, item 3b
29 CFR 1910.134(a)(2) · Respiratory protection
Serious$0$0Jun 2, 1998Closed
Citation 1, item 3c
29 CFR 1910.1000(e) · Air contaminants
Serious$0$0Jun 2, 1998Closed
Citation 1, item 4 Serious$150$150Jun 2, 1998Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1000 · Air contaminants

29 CFR 1910.1000(a)(2)

(2) Other substances—8-hour Time Weighted Averages. An employee's exposure to any substance in Table Z-1, the exposure limit of which is not preceded by a “C”, shall not exceed the 8-hour Time Weighted Average given for that substance in any 8-hour work shift of a 40-hour work week.

29 CFR 1910.1000(e)

(e) To achieve compliance with paragraphs (a) through (d) of this section, administrative or engineering controls must first be determined and implemented whenever feasible. When such controls are not feasible to achieve full compliance, protective equipment or any other protective measures shall be used to keep the exposure of employees to air contaminants within the limits prescribed in this section. Any equipment and/or technical measures used for this purpose must be approved for each particular use by a competent industrial hygienist or other technically qualified person. Whenever respirators are used, their use shall comply with 1910.134.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(10)

(10) Illumination. When spraying areas are illuminated through glass panels or other transparent materials, only fixed lighting units shall be used as a source of illumination. Panels shall effectively isolate the spraying area from the area in which the lighting unit is located, and shall be of a noncombustible material of such a nature or so protected that breakage will be unlikely. Panels shall be so arranged that normal accumulations of residue on the exposed surface of the panel will not be raised to a dangerous temperature by radiation or conduction from the source of illumination.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.212 · Machine guarding

29 CFR 1910.217 · Mechanical power presses

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.254 · Arc welding and cutting

29 CFR 1910.305 · Electrical wiring methods

29 CFR 5205.870

29 CFR 5206.700

Other ornamental and architectural metal work manufacturing employers in Minnesota

Alert subscribers get notified of each newly cited employer in Minnesota the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.