OSHA SearchOSHA records by employer

Siwek Lumber - Millwork Corp: OSHA inspections and violations

Mpls, Minnesota · Hardware Stores · NAICS 444130

2inspections
12citation items
$6,900current penalties
Jul 31, 2024last inspection

Since 1985, OSHA inspectors have visited Siwek Lumber - Millwork Corp in Minnesota 2 times.

The most recent inspection opened on Jul 31, 2024 as a planned inspection, in Minneapolis.

In all, OSHA issued 12 citation items: 5 serious and 7 other-than-serious.

The penalties, $6,900 in total, stand where OSHA first set them.

The rule cited most here is 1910.23 (ladders in general industry), 2 times.

Among retail employers, the typical cited inspection since 2015 ends with a $1,750 penalty. Siwek Lumber - Millwork Corp averages $6,900 across 1 cited inspection.

Siwek Lumber - Millwork Corp: OSHA citation items per year, 1985 to 2024
Citation items per year, by inspection date.

Minnesota · latest 90 days of OSHA records

380employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Minnesota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Minnesota

Checking a subcontractor, a client or your own company? Watch Siwek Lumber - Millwork Corp and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347655953 OPENED JUL 31, 2024Closed

Planned · Complete · Safety · 48 employees at the site · Closed Sep 13, 2024

2536 Ne Marshall St, Minneapolis, MN 55418 · Hardware Stores · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 182.653(02)
Serious$2,700$2,700Aug 19, 2024Final
Citation 1, item 2
29 CFR 182.676
Serious$300$300Aug 19, 2024Final
Citation 1, item 3
29 CFR 1910.28(b)(1)(i) · Fall protection in general industry
Serious$900$900Aug 19, 2024Final
Citation 1, item 4
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Serious$900$900Aug 19, 2024Final
Citation 1, item 5 Serious$900$900Aug 19, 2024Final
Citation 2, item 1
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Other-than-serious$600$600Aug 19, 2024Final
Citation 2, item 2
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Other-than-serious$600$600Aug 19, 2024Final

Inspection 2922789 OPENED JUN 21, 1985Closed

Planned · Complete · Safety · 15 employees at the site · Closed Jul 18, 1985

2536 Ne Marshall St, Mpls, MN 55418 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(d)(1)(iii) · Guarding floor and wall openings and holes
Other-than-serious$0$0Jul 2, 1985Closed
Citation 1, item 2
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Other-than-serious$0$0Jul 2, 1985Closed
Citation 1, item 3
29 CFR 1910.106(d)(2)(i) · Flammable liquids
Other-than-serious$0$0Jul 2, 1985Closed
Citation 1, item 4
29 CFR 1910.24(i) · Fixed industrial stairs
Other-than-serious$0$0Jul 2, 1985Closed
Citation 1, item 5
29 CFR 1910.110(e)(4)(iii) · Storage and handling of liquefied petroleum gases
Other-than-serious$0$0Jul 2, 1985Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(2)(i)

(2) Design, construction, and capacity of containers—(i) General. Only approved containers and portable tanks shall be used. Metal containers and portable tanks meeting the requirements of and containing products authorized by chapter I, title 49 of the Code of Federal Regulations (regulations issued by the Hazardous Materials Regulations Board, Department of Transportation), shall be deemed to be acceptable.

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

29 CFR 1910.110(e)(4)(iii)

(iii) Permanent and removable fuel containers shall be securely mounted to prevent jarring loose, slipping, or rotating, and the fastenings shall be designed and constructed to withstand static loading in any direction equal to twice the weight of the tank and attachments when filled with fuel using a safety factor of not less than four based on the ultimate strength of the material to be used. Field welding, when necessary, shall be made only on saddle plates, lugs or brackets, originally attached to the container by the tank manufacturer.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(2)(ii)

(ii) In addition, the employer must establish and implement those elements of a written respiratory protection program necessary to ensure that any employee using a respirator voluntarily is medically able to use that respirator, and that the respirator is cleaned, stored, and maintained so that its use does not present a health hazard to the user. Exception: Employers are not required to include in a written respiratory protection program those employees whose only use of respirators involves the voluntary use of filtering facepieces (dust masks).

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.24 · Fixed industrial stairs

29 CFR 1910.28 · Fall protection in general industry

29 CFR 1910.334 · Using electrical equipment

29 CFR 5205.116

Other hardware stores employers in Minnesota

Alert subscribers get notified of each newly cited employer in Minnesota the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.