OSHA SearchOSHA records by employer

Small Business Group, Inc.: OSHA inspections and violations

Beaufort, South Carolina · Commercial and Institutional Building Construction · NAICS 236220

10inspections
17citation items
$17,224current penalties
May 1, 2018last inspection

Since 2008, OSHA inspectors have visited Small Business Group, Inc. in South Carolina 10 times.

The most recent inspection opened on May 1, 2018 as a planned inspection, in Beaufort.

In all, OSHA issued 17 citation items: 13 serious and 4 other-than-serious.

The proposed penalties came to $36,110; today they stand at $17,224, 52% less.

The rule cited most here is 1926.502 (fall protection systems), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Small Business Group, Inc. averages $0 across 1 cited inspection.

Small Business Group, Inc.: OSHA citation items per year, 2008 to 2018
Citation items per year, by inspection date.

South Carolina · latest 90 days of OSHA records

42employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in South Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in South Carolina

Checking a subcontractor, a client or your own company? Watch Small Business Group, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343158770 OPENED MAY 1, 2018Closed

Planned · Complete · Safety · 9 employees at the site · Closed Jul 24, 2018

Building 933 Marine Corps Air Station, Beaufort, SC 29904 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(k)(6) · Respiratory protection
Other-than-serious$0$0Jun 27, 2018Final

Inspection 339664468 OPENED APR 2, 2014Closed

Planned · Complete · Safety · 2 employees at the site · Closed Apr 25, 2014

Building 617 Mcas, Beaufort, SC 29902 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 339664112 OPENED APR 1, 2014Closed

Planned · Complete · Safety · 3 employees at the site · Closed May 30, 2014

Building 626 Mcas, Beaufort, SC 29902 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$3,080$1,232May 8, 2014Final
Citation 1, item 2
29 CFR 1926.150(c)(1)(i) · Fire protection
Serious$3,080$1,232May 8, 2014Final
Citation 1, item 3
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Serious$3,850$1,540May 8, 2014Final
Citation 1, item 4
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$3,850$1,540May 8, 2014Final
Citation 1, item 6
29 CFR 1926.502(f)(1)(iii) · Fall protection systems
Serious$3,850$1,540May 8, 2014Final
Citation 1, item 7
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$3,850$1,540May 8, 2014Final

Inspection 335205183 OPENED JUL 10, 2012Closed

Follow-up · Partial · Safety · 4 employees at the site · Closed Jul 31, 2012

Building 616 Mcas, Beaufort, SC 29904 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 308330406 OPENED JAN 10, 2012Closed

Planned · Complete · Safety · 4 employees at the site · Closed Mar 6, 2012

Building 616 Mcas, Beaufort, SC 29904 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Serious$2,550$2,550Feb 23, 2012Closed
Citation 2, item 1
29 CFR 1926.405(b)(1) · Job-site wiring
Other-than-serious$0$0Feb 23, 2012Closed

Inspection 308330422 OPENED JAN 10, 2012Closed

Planned · Complete · Health · 4 employees at the site · Closed Jan 10, 2012

Building 616 Mcas, Beaufort, SC 29904 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 308330216 OPENED SEP 8, 2011Closed

Planned · Complete · Safety · 4 employees at the site · Closed Jan 25, 2012

Building 11, Parris Island, SC 29905 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.405(e)(1) · Job-site wiring
Serious$3,500$2,975Dec 7, 2011Closed
Citation 1, item 1b
29 CFR 1926.405(j)(2)(ii) · Job-site wiring
Serious$0$0Dec 7, 2011Closed
Citation 1, item 1c
29 CFR 1926.432(a)(2) · Environmental deterioration of equipment
Serious$4,900$0Dec 7, 2011Closed
Citation 1, item 3a
29 CFR 1926.502(b)(3) · Fall protection systems
Serious$3,500$2,975Dec 7, 2011Closed
Citation 1, item 3b
29 CFR 1926.502(i)(3) · Fall protection systems
Serious$0$0Dec 7, 2011Closed
Citation 2, item 1
29 CFR 1926.501(b)(4)(ii) · Fall protection in construction
Other-than-serious$0$0Dec 7, 2011Closed
Citation 2, item 2
29 CFR 1926.502(i)(4) · Fall protection systems
Other-than-serious$0$0Dec 7, 2011Closed

Inspection 308328301 OPENED AUG 26, 2009Closed

Planned · Complete · Health · 1 employee at the site · Closed Oct 30, 2009

782 Gear Locker, Shanghai Street, Parris Island, SC 29905 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

2 older inspections

Inspection 308328392 OPENED AUG 26, 2009Closed

Planned · Complete · Safety · 1 employee at the site · Closed Sep 18, 2009

782 Gear Locker, Shanghai Street, Parris Island, SC 29905 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 308327345 OPENED SEP 18, 2008Closed

Planned · Complete · Safety · 1 employee at the site · Closed Dec 23, 2008

Building 727 Mcas, Beaufort, SC 29904 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(b)(2) · Job-site wiring
Serious$100$100Oct 27, 2008Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(k)(6)

(6) The basic advisory information on respirators, as presented in appendix D of this section, shall be provided by the employer in any written or oral format, to employees who wear respirators when such use is not required by this section or by the employer.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(i)

(c) Portable firefighting equipment—(1) Fire extinguishers and small hose lines. (i) A fire extinguisher, rated not less than 2A, shall be provided for each 3,000 square feet of the protected building area, or major fraction thereof. Travel distance from any point of the protected area to the nearest fire extinguisher shall not exceed 100 feet.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.432 · Environmental deterioration of equipment

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems