1inspections
20citation items
$6,350current penalties
Feb 16, 2023last inspection

Smi Signs Systems, Inc. has one OSHA inspection on record in Maryland.

OSHA opened it on Feb 16, 2023 after a complaint, in Frederick, and the case has not closed yet.

From that inspection OSHA issued 20 citation items: 7 serious and 13 other-than-serious.

OSHA proposed $6,350 in penalties and the amount has not been reduced.

Most often, OSHA cited 1910.134, respiratory protection (6 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Smi Signs Systems, Inc. averages $6,350 over 1 cited inspection in that time.

Smi Signs Systems, Inc.: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

185employers cited

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Smi Signs Systems, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346513880 OPENED FEB 16, 2023Open

Complaint · Complete · Health · 41 employees at the site · Open

3903 Cornell Place, Frederick, MD 21703 · Sign Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(d)(2)(i) · Flammable liquids
Serious$1,500$1,500Aug 11, 2023Contested
Citation 1, item 2
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$1,500$1,500Aug 11, 2023Contested
Citation 1, item 3
29 CFR 1910.242(b) · Hand and power tools
Serious$1,500$1,500Aug 11, 2023Contested
Citation 1, item 4a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$1,500$1,500Aug 11, 2023Contested
Citation 1, item 4b
29 CFR 1910.1200(f)(6)(ii) · Hazard communication
Serious$0$0Aug 11, 2023Contested
Citation 1, item 4c
29 CFR 1910.1200(g)(1) · Hazard communication
Serious$0$0Aug 11, 2023Contested
Citation 1, item 4d
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Aug 11, 2023Contested
Citation 2, item 1
29 CFR 1904.32(a) · Yearly injury summary
Other-than-serious$350$350Aug 11, 2023Contested
Citation 2, item 2
29 CFR 1910.37(a)(3) · Exit routes
Other-than-serious$0$0Aug 11, 2023Contested
Citation 2, item 3
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Other-than-serious$0$0Aug 11, 2023Contested
Citation 2, item 4
29 CFR 1910.107(b)(9) · Spray painting and finishing
Other-than-serious$0$0Aug 11, 2023Contested
Citation 2, item 5
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Aug 11, 2023Contested
Citation 2, item 6
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$0$0Aug 11, 2023Contested
Citation 2, item 7
29 CFR 1910.134(c)(3) · Respiratory protection
Other-than-serious$0$0Aug 11, 2023Contested
Citation 2, item 8
29 CFR 1910.134(e)(1) · Respiratory protection
Other-than-serious$0$0Aug 11, 2023Contested
Citation 2, item 9
29 CFR 1910.134(f)(2) · Respiratory protection
Other-than-serious$0$0Aug 11, 2023Contested
Citation 2, item 10
29 CFR 1910.134(g)(1)(i)(a) · Respiratory protection
Other-than-serious$0$0Aug 11, 2023Contested
Citation 2, item 11
29 CFR 1910.134(k)(1) · Respiratory protection
Other-than-serious$0$0Aug 11, 2023Contested
Citation 2, item 12
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Other-than-serious$0$0Aug 11, 2023Contested
Citation 2, item 13
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Other-than-serious$0$0Aug 11, 2023Contested

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.32 · Yearly injury summary

29 CFR 1904.32(a)

(a) Basic requirement. At the end of each calendar year, you must:

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(2)(i)

(2) Design, construction, and capacity of containers—(i) General. Only approved containers and portable tanks shall be used. Metal containers and portable tanks meeting the requirements of and containing products authorized by chapter I, title 49 of the Code of Federal Regulations (regulations issued by the Hazardous Materials Regulations Board, Department of Transportation), shall be deemed to be acceptable.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes

Other sign manufacturing employers in Maryland