OSHA SearchOSHA records by employer

Sonic Connectors, Ltd.: OSHA inspections and violations

Garden City, Texas · Support Activities for Oil and Gas Operations · NAICS 213112

4inspections
4citation items
$24,711current penalties
Jan 14, 2025last inspection

OSHA has inspected Sonic Connectors, Ltd. 4 times in Texas since 2023.

The latest one began on Jan 14, 2025 to follow up on an earlier case, in Midland.

Those inspections ended with 4 citation items: 4 serious.

Penalties were first proposed at $53,534 and now stand at $24,711, 54% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for mining and oil and gas employers since 2015 is $2,880, and Sonic Connectors, Ltd. averages $8,237 (3 cited inspections).

Sonic Connectors, Ltd. also files yearly injury logs with OSHA, summarized below.

It reported 1 severe injury to OSHA since 2015.

Sonic Connectors, Ltd.: OSHA citation items per year, 2023 to 2025
Citation items per year, by inspection date.

Want to know if OSHA cites Sonic Connectors, Ltd. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 347985681 OPENED JAN 14, 2025Closed

Follow-up · Partial · Safety · 170 employees at the site · Closed Mar 4, 2025

11915 W. County Rd 100, Midland, TX 79706 · Oil and Gas Field Machinery and Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 347660664 OPENED JUL 31, 2024Closed

Planned · Complete · Safety · 1 employee at the site · Closed Oct 16, 2024

Watchman 30-25 Ub 2 Wa 10-miles Ne From Coyanosa, Coyanosa, TX 79730 · Support Activities for Oil and Gas Operations · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.28(b)(1)(i) · Fall protection in general industry
Serious$13,690$10,000Aug 16, 2024Final
Citation 1, item 1b
29 CFR 1910.30(c)(3) · Training requirements
Serious$13,690$0Aug 16, 2024Final

Inspection 347371494 OPENED MAR 26, 2024Closed

Planned · Complete · Safety · 1 employee at the site · Closed Jul 26, 2024

Ensign Rig #773 4 Miles Se From Odessa, Odessa, TX 79760 · Oil and Gas Field Machinery and Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(m)(2) · Forklifts and other powered industrial trucks
Serious$11,636$6,000Jun 10, 2024Final

Inspection 347072241 OPENED OCT 27, 2023Closed

Referral · Partial · Safety · 2 employees at the site · Closed Mar 1, 2024

Gardendale Blue Well 0904, Garden City, TX 79739 · Support Activities for Oil and Gas Operations · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(b)(6) · Flammable liquids
Serious$14,518$8,711Feb 7, 2024Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Midland site logged 2 recordable injuries or illnesses among about 210 workers: 0.7 per 100 full-time workers, against a median of 2.7 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Sonic Connectors LTD
Midland · 2025
210 200.72.7
Sonic Connectors Ltd.
Midland · 2024
199 110.42.7

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Oct 24, 2023, Garden City: Hospitalization · heat (thermal) burns, unspecified · multiple body parts, n.e.c.

An employee was using a torque pump to tighten a frac valve when a spark ignited flammable gas and caused a flash fire. The employee sustained burns to their neck and arms.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(m)(2)

(2) No person shall be allowed to stand or pass under the elevated portion of any truck, whether loaded or empty.

29 CFR 1910.28 · Fall protection in general industry

29 CFR 1910.28(b)(1)(i)

(b) Protection from fall hazards—(1) Unprotected sides and edges. (i) Except as provided elsewhere in this section, the employer must ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the following:

29 CFR 1910.30 · Training requirements

29 CFR 1910.30(c)(3)

(3) When inadequacies in an affected employee's knowledge or use of fall protection systems or equipment indicate that the employee no longer has the requisite understanding or skill necessary to use equipment or perform the job safely.

Other support activities for oil and gas operations employers in Texas

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.